# K212446: NuVasive Anterior Cervical Plate Systems

- Pathway: 510(k) (Traditional)
- Applicant: Nu Vasive, Incorporated
- Decided: Nov 3, 2021 after 90 days
- Product code: KWQ (Appliance, Fixation, Spinal Intervertebral Body)
- Device class: 2
- Regulation: 21 CFR 888.3060
- Recalls of this device: none
- Data: FDA decisions to Oct 25, 2026; recalls to Oct 12, 2026

## Lineage
Longest line of descent: 7 generations back to K922087 (1992). 26 ancestors in all.
1 later device descends from it; 1 cites it directly.
0 of 28 devices in its family (counting itself) have a Class I recall.

## Predicates on the family tree (from the FDA summary)
- K071329: Nuvasive Helix Acp System, Nuvasive, Inc. (2007) Summary page 7.
- K073275: Nuvasive Helix Mini Acp System, Nuvasive, Inc. (2008) Summary page 7.
- K083341: Nuvasive Helix-T Acp System, Nuvasive, Inc. (2009) Summary page 7.
- K093804: Nuvasive Helix Revolution Acp System, Nuvasive, Inc. (2010) Summary page 7.
- K203253: NuVasive ACP System, Nu Vasive, Incorporated (2020) Summary page 7.
- K122910: Archon Anterior Cervical Plate Syste,, Nu Vasive, Incorporated (2012) Summary page 7.
- K131025: Archon Anterior Cervical Plate System, Nuvasive, Inc. (2013) Summary page 7.
- K053581: Nuvasive Smartplate Gradient Plus System, Nuvasive, Inc. (2006) Summary page 7.

## Most influential descendants
- K251965: Proximity Anterior Cervical Plate System; Segmental Plating System (SPS) (2025), 0 descendants of its own

## Indications for use
The NuVasive® ACP System is intended for anterior screw fixation of the cervical spine C2-C7 for the following indications: degenerative disc disease (as defined by neck pain of discogenic origin with degeneration of the disc confirmed by patient history and radiographic studies), trauma (including fractures), tumors, deformity (defined as kyphosis, lordosis, or scoliosis), pseudarthrosis, failed previous fusion, spondylolisthesis, and spinal stenosis. The NuVasive Archon Anterior Cervical Plate System is intended for anterior screw fixation of the cervical spine. These implants have been designed to provide stabilization as an adjunct to cervical fusion. Indications for the use of. the implant system include degenerative disc disease defined as neck pain of discogenic origin with the degeneration of the disc confirmed by history and radiographic studies, spondylolisthesis, trauma, spinal stenosis, deformity, tumor, pseudarthrosis or failed previous fusion. Additionally, the three-hale version of the implant system may be appropriate only for patients with large vertebral bodies, and is particularly suited for use following corpectomies for the treatment of tumors and burst fractures. WARNING: The NuVasive Archon Anterior Cervical Plate System is not intended for screw attachment or fixation to the posterior elements (pedicles) of the cervical, thoracic or lumbar spine. The NuVasive SmartPlate Gradient Plus System is intended for anterior screw fixation of the cervical spine. These implants have been designed to provide stabilization as an adjunct to cervical fusion. Indications for the use of this implant system include degenerative disc disease defined as neck pain of discogenic origin with the degeneration of the disc confirmed by history and radiographic studies, spondylolisthesis, trauma, spinal stenosis, deformity, tumor, pseudarthrosis or failed previous fusion. WARNING: The NuVasive SmartPlate Gradient Plus System is not intended for screw attachment or fixation to the posterior elements (pedicles) of the cervical, thoracic or lumbar spine. The NuVasive HELIX Anterior Cervical Plating System is intended for anterior screw fixation of the cervical spine. These implants have been designed to provide stabilization as an adjunct to cervical fusion. Indications for the use of this implant system include degenerative disc disease defined as neck pain of discogenic origin with the degeneration of the disc confirmed by history and radiographic studies, spondylolisthesis, trauma, spinal stenosis, deformity, tumor, pseudarthrosis or failed previous fusion. WARNING: The NuVasive HELIX Anterior Cervical Plating System is not intended for screw attachment or fixation to the posterior elements (pedicles) of the cervical, thoracic or lumbar spine.

Source page: https://510kreport.com/device/K212446