The O R Company Pty, Ltd. · LKF Cannula, Manipulator/Injector, Uterine
Cleared on Jan 10, 2022 as substantially equivalent to K092980 (Panpac Medical Corporation, 2010) after a 154-day review. Its family tree reaches back 1 generation to 2010.
- Decided
- Jan 10, 2022
- Review
- 154 days
- Class
- Class II
- Product code
- LKF
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 1 generation to K092980 (2010). No later device cites it as a predicate yet.
- Root · 1 generation backK092980 Panpac Uterine Manipulator Injector, Model Umi 4.5Panpac Medical Corporation · 2010
- This deviceK212505 DUMI ManipulatORThe O R Company Pty, Ltd. · 2022
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −1 | K092980 | Panpac Uterine Manipulator Injector, Model Umi 4.5 | Panpac Medical Corporation | 2010 | — |
| 0 (this device) | K212505 | DUMI ManipulatOR | The O R Company Pty, Ltd. | 2022 | — |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LKF? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LKF device
- #1 K241693 FemChec Controlled Saline-Air Device (FCD-250)score 11.6 · 3 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K092980 | Panpac Uterine Manipulator Injector, Model Umi 4.5Summary page 4…l: Obstetrics/Gynecology Predicate Devices: Panpac Medical Corporation ---- Panpac Uterine Manipulator Injector, Model UMI 4.5 (K092980) The predicate device has not been subjected to a recall. Device Description: The… | 2010 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- Its one ancestor has no recall.
- 1 other device also cites its predicate K092980.
How does its category compare?
All LKF devicesLKF Cannula, Manipulator/Injector, Uterine: FDA decisions, review times, recalls and adverse event reports over 20 years. 2022, this device’s year, is highlighted.
FDA decisions per year · LKF
2in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · LKF
136in 2024
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LKF
3in 2022
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · LKF
95in 2025
MAUDE reports naming product code LKF, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 3 | 141 | 0 | 36 |
| 2008 | 0 | — | 2 | 59 |
| 2009 | 2 | — | 0 | 53 |
| 2010 | 6 | 178 | 0 | 46 |
| 2011 | 3 | 187 | 0 | 98 |
| 2012 | 0 | — | 2 | 104 |
| 2013 | 3 | 266 | 0 | 53 |
| 2014 | 3 | 169 | 0 | 45 |
| 2015 | 5 | 140 | 0 | 53 |
| 2016 | 1 | — | 0 | 62 |
| 2017 | 1 | — | 0 | 64 |
| 2018 | 4 | 267 | 0 | 23 |
| 2019 | 1 | — | 0 | 76 |
| 2020 | 0 | — | 0 | 119 |
| 2021 | 0 | — | 0 | 189 |
| 2022 | 4 | 79 | 3 | 100 |
| 2023 | 0 | — | 0 | 88 |
| 2024 | 3 | 136 | 0 | 125 |
| 2025 | 2 | — | 0 | 95 |
| 2026 | 0 | — | 0 | — |
What is it indicated for?
The use of the DUMI ManipulatOR is indicated in diagnostic laparoscopy, mini laparotomy, fertility exams, and salpingoplastic procedures where manipulation of the uterus is required.
Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.
https://510kreport.com/device/K212505 · printed Nov 4, 2026
Cite this page
510(k) Report. “K212505: DUMI ManipulatOR.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K212505
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026