510(k) · Cleared
ClearedMedical Examination Gloves (Tested for Use with Chemotherapy)
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Guangdong Gymda Medical Technology Co.,Ltd · LZA Polymer Patient Examination Glove
Cleared on Nov 7, 2021 as substantially equivalent to K190860 (Ever Growth (Vietnam) Co., Ltd., 2019) after a 90-day review. Its family tree reaches back 2 generations to 2019.
- Decided
- Nov 7, 2021
- Review
- 90 days
- Class
- Class I
- Product code
- LZA
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 2 generations to K182176 (2019). No later device cites it as a predicate yet.
- Root · 2 generations backK182176 Polychloroprene Powder Free Sterile Surgical Gloves, White, Tested…Pt. Medisafe Technologies · 2019
- 1 generation backK190860 Disposable Powder Free Nitrile Examination Glove, Tested For Use…Ever Growth (Vietnam) Co., Ltd. · 2019
- This deviceK212506 Medical Examination Gloves (Tested for Use with Chemotherapy)Guangdong Gymda Medical Technology Co.,Ltd · 2021
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −2 | K182176 | Polychloroprene Powder Free Sterile Surgical Gloves, White, Tested for Use… | Pt. Medisafe Technologies | 2019 | — |
| −1 | K190860 | Disposable Powder Free Nitrile Examination Glove, Tested For Use With… | Ever Growth (Vietnam) Co., Ltd. | 2019 | — |
| 0 (this device) | K212506 | Medical Examination Gloves (Tested for Use with Chemotherapy) | Guangdong Gymda Medical Technology Co.,Ltd | 2021 | — |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LZA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LZA device
- #1 K192333 Blue Nitrile Examination Gloves Powder Freescore 71.0 · 2 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K190860 | Disposable Powder Free Nitrile Examination Glove, Tested For Use With Chemotherapy…Summary page 4…h Chemotherapy Drugs, Disposable Powder Free Nitrile Examination Glove, Tested For Use With Chemotherapy Drugs, Orange Color 510(k) number: K190860 1 of 7 5.0 Device Description The subject device is single use, disposable g… | 2019 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 2 years and passes through 3 companies; a new generation was cleared every 1.9 years on median.
- None of the 2 ancestors has a recall.
- 11 other devices also cite its predicate K190860.
How does its category compare?
All LZA devicesLZA Polymer Patient Examination Glove: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.
FDA decisions per year · LZA
24in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · LZA
110in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LZA
3so far in 2026, the most since 2007
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · LZA
73in 2025
MAUDE reports naming product code LZA, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 21 | 95 | 0 | 7 |
| 2008 | 18 | 97 | 0 | 2 |
| 2009 | 28 | 112 | 0 | 12 |
| 2010 | 31 | 97 | 0 | 12 |
| 2011 | 26 | 122 | 0 | 9 |
| 2012 | 33 | 110 | 0 | 11 |
| 2013 | 20 | 130 | 0 | 10 |
| 2014 | 27 | 197 | 0 | 8 |
| 2015 | 20 | 112 | 1 | 12 |
| 2016 | 30 | 171 | 1 | 25 |
| 2017 | 44 | 124 | 0 | 4 |
| 2018 | 22 | 178 | 0 | 3 |
| 2019 | 25 | 212 | 0 | 21 |
| 2020 | 30 | 101 | 0 | 4 |
| 2021 | 139 | 111 | 0 | 20 |
| 2022 | 146 | 111 | 0 | 19 |
| 2023 | 62 | 92 | 0 | 24 |
| 2024 | 30 | 89 | 0 | 76 |
| 2025 | 24 | 110 | 0 | 73 |
| 2026 | 15 | 103 | 3 | — |
What is it indicated for?
A patient examination gloves is a disposable device intended for medical purpose that is worn on the examiner's hand or fingers to prevent contamination between patient and examiner. In addition, these gloves were tested for use with chemotherapy drugs in accordance with ASTM D6978-05 Standard Practice for Assessment of Medical gloves to Permeation by Chemotherapy Drugs. Chemotherapy Drug Concentration Breakthrough Detection Time in Minutes Carmustine…
Read the full statement (166 words)
A patient examination gloves is a disposable device intended for medical purpose that is worn on the examiner's hand or fingers to prevent contamination between patient and examiner. In addition, these gloves were tested for use with chemotherapy drugs in accordance with ASTM D6978-05 Standard Practice for Assessment of Medical gloves to Permeation by Chemotherapy Drugs.
Chemotherapy Drug Concentration Breakthrough Detection Time in Minutes
Carmustine (BCNU) 3.3 mg/ml (3,300 ppm) 10.9 Minutes
Cisplatin 1.0 mg/ml(1,000 ppm) > 240 Minutes
Cyclophosphamide (Cytoxan) 20.0 mg/ml(20,000 ppm) > 240 Minutes
Dacarbazine (DTIC) 10.0 mg/ml(10,000 ppm) > 240 Minutes
Doxorubicin HCL (Adriamycin) 2.0 mg/ml(2,000 ppm) > 240 Minutes
Etoposide (Toposar) 20.0 mg/ml(20,000 ppm) > 240 Minutes
Fluorouracil (Adrucil) 50.0 mg/ml(50,000 ppm) > 240 Minutes
Paclitaxel (Taxol) 6.0 mg/ml(6,000 ppm) > 240 Minutes
Thio TEPA 10.0 mg/ml(10,000 ppm) 15.2 Minutes
Please note that the following drugs have low permeation times:
Carmustine (BCNU) 3.3 mg/ml 10.9 Minutes
Thio-Tepa 10.0 mg/ml 15.2 Minutes
Warning: Please do not use with Carmustine (BCNU) and Thiotepa.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K212506 · printed Nov 4, 2026
Cite this page
510(k) Report. “K212506: Medical Examination Gloves (Tested for Use with Chemotherapy).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K212506
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026