510(k) Report

510(k) · Cleared

Recalled · Class II · 2026

7 Series Phototherapy Device

K212510510(k) TraditionalCleared Nov 4, 202186-day reviewClass II21 CFR 878.4630Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Daavlin Distributing Co. · FTC Light, Ultraviolet, Dermatological

Cleared on Nov 4, 2021 as substantially equivalent to K182215 (Daavlin Distributing Company, 2018) after an 86-day review. Its family tree reaches back 4 generations to 1983. It has been recalled once.

Decided
Nov 4, 2021
Review
86 days
Class
Class II
Product code
FTC
Recalls
1
Predicates
1

Its longest line of descent runs back 4 generations to K828654 (1983). 9 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 4 generations backK828654 Uvb Cabinet or Goekerman Cabinet, Model Spectra 305Daavlin Co. · 1983
  2. 3 generations backK050695 Flex Controlled Phototherapy EquipmentDaavlin Distributing Co. · 2005
  3. 2 generations backK100378 1 Series Model 1 Series T2, 1 Series X2, 1 Series T4, 1 Series X4Daavlin Distributing Co. · 2010 · Recalled
  4. 1 generation backK182215 ClearLink Controlled Phototherapy EquipmentDaavlin Distributing Company · 2018 · Recalled
  5. This deviceK212510 7 Series Phototherapy DeviceDaavlin Distributing Co. · 2021
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K828654Uvb Cabinet or Goekerman Cabinet, Model Spectra 305Daavlin Co.1983—
−3K050695Flex Controlled Phototherapy EquipmentDaavlin Distributing Co.2005—
−2K1003781 Series Model 1 Series T2, 1 Series X2, 1 Series T4, 1 Series X4Daavlin Distributing Co.20101
−1K182215ClearLink Controlled Phototherapy EquipmentDaavlin Distributing Company20181
0 (this device)K2125107 Series Phototherapy DeviceDaavlin Distributing Co.2021—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198510
200210
200310
200710
200810
FIG. 1 — Lineage of K212510, 1983–2021Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FTC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FTC device

  1. #1 K242977 308nm Excimer Phototherapy Device (CN-308E…score 14.8 · 21 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K182215ClearLink Controlled Phototherapy Equipment
Summary page 4
…Class II Product Code: FTC Panel: General and Plastic Surgery Predicate Devices: ClearLink Phototherapy Equipment 510(k) Numbers: K182215 Product Code: FTC Company: Daavlin Distributing Company The 7 Series Phototherap…
Daavlin Distributing Company20181

Also cleared against K182215: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Mar 5, 2026Class IIZ-2743-2026Software Design ChangeCalibrated Output was not calculating correctly - UV Sensor GAIN being applied was incorrect - GAIN seemed to be "4/5" instead of "7" (counts were at ~1000 instead of ~5000).

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 38 years and passes through 3 companies; a new generation was cleared every 8.5 years on median.
  • 2 of the 9 ancestors have a recall of any class.
  • 1 other device also cites its predicate K182215.

How does its category compare?

All FTC devices

FTC Light, Ultraviolet, Dermatological: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.

FDA decisions per year · FTC

3in 2025

2007: 42008: 32009: 22010: 12011: 52012: 12013: 12014: 22015: 32016: 12017: 22018: 32019: 22020: 52021: 32022: 12023: 42024: 12025: 32026 (partial year): 4
2007high 5 (2011) · low 1 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FTC

76in 2025

2007: 53 days median2008: 41 days median2011: 125 days median2015: 98 days median2018: 88 days median2020: 237 days median2021: 89 days median2023: 48 days median2025: 76 days median2026 (partial year): 91 days median
2007high 237 (2020) · low 41 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FTC

3so far in 2026, the most since 2007

2008: 12025: 12026 (partial year): 3
2007high 3 (2026) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FTC

8in 2025

2010: 22012: 12013: 12014: 12015: 82016: 22017: 22019: 142020: 42021: 482022: 42023: 52024: 42025: 8
2007high 48 (2021) · low 0 (2007)2025

MAUDE reports naming product code FTC, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
200745300
200834110
20092—00
20101—02
2011512500
20121—01
20131—01
20142—01
201539808
20161—02
20172—02
201838800
20192—014
2020523704
2021389048
20221—04
202344805
20241—04
202537618
20264913—

What is it indicated for?

The 7 Series Phototherapy Devices are indicated for use to treat diagnosed skin disorders such, as but not limited to, psoriasis, vitiligo, and atopic dermatitis (eczema) under the direction of a physician. The population may range from pediatric to geriatric.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K212510: 7 Series Phototherapy Device.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K212510

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026