BTL-995-rTMS

K212723510(k) TraditionalCleared Mar 4, 2022189-day reviewClass II21 CFR 882.5805

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

BTL Industries, Inc. · OBP Transcranial Magnetic Stimulator

Cleared on Mar 4, 2022 as substantially equivalent to K150641 (Tonica Elektronik A/S, 2015) after a 189-day review. Its family tree reaches back 5 generations to 2008. 1 later device descends from it.

Decided
Mar 4, 2022
Review
189 days
Class
Class II
Product code
OBP
Recalls
None
Predicates
1

Its longest line of descent runs back 5 generations to DEN070003 (2008). 1 later device descends from it, 1 citing it directly.

  1. Root · 5 generations backDEN070003 Neurostar TMS SystemNeuronetics · 2008
  2. 4 generations backK083538 Neurostar TMS Therapy System, Model 1.1Neuronetics · 2008 · Recalled
  3. 3 generations backK130233 Neurostar TMS Therapy SystemNeuronetics · 2013
  4. 2 generations backK133408 Neurostar TMS Therapy SystemNeuronetics · 2014
  5. 1 generation backK150641 MagVita TMS Therapy SystemTonica Elektronik A/S · 2015
  6. This deviceK212723 BTL-995-rTMSBTL Industries, Inc. · 2022
  7. Descendant · cites it directly · 0 of its ownK260691 BTL-699BTL Industries, Inc. · 2026

Most influential descendants

Showing 1 of 1 · See all
  • K260691BTL-699BTL Industries, Inc. · 2026 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5DEN070003Neurostar TMS SystemNeuronetics2008—
−4K083538Neurostar TMS Therapy System, Model 1.1Neuronetics20081
−3K130233Neurostar TMS Therapy SystemNeuronetics2013—
−2K133408Neurostar TMS Therapy SystemNeuronetics2014—
−1K150641MagVita TMS Therapy SystemTonica Elektronik A/S2015—
0 (this device)K212723BTL-995-rTMSBTL Industries, Inc.2022—
+1K260691BTL-699BTL Industries, Inc.2026—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202610
FIG. 1 — Lineage of K212723, 2008–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in OBP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new OBP device

  1. #1 K251119 MagVenture TMS Therapy Systemscore 21.8 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K150641MagVita TMS Therapy System
Summary page 5
…t to the current product that is already cleared for distribution in the USA under the following 510(k) Premarket Notification number: ● MagVita TMS Therapy System (K150641) Product Description The BTL-995-rTMS is a non-invasive therapeutic device that produces and delivers magnetic field to induce…
Tonica Elektronik A/S2015—

Also cleared against K150641: 10 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K260691BTL-699BTL Industries, Inc.20260

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 14 years and passes through 3 companies; a new generation was cleared every 1.3 years on median.
  • 1 of the 5 ancestors has a recall of any class.
  • Of its descendants, K260691 (BTL Industries, Inc., 2026) has gone furthest, with 0 descendants of its own.
  • 10 other devices also cite its predicate K150641.

How does its category compare?

All OBP devices

OBP Transcranial Magnetic Stimulator: FDA decisions, review times, recalls and adverse event reports over 20 years. 2022, this device’s year, is highlighted.

FDA decisions per year · OBP

12in 2025

2008: 22013: 22014: 12015: 22016: 32017: 82018: 42019: 32020: 12021: 52022: 62023: 72024: 52025: 122026 (partial year): 8
2007high 12 (2025) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · OBP

125in 2025

2016: 101 days median2017: 73 days median2018: 144 days median2019: 156 days median2021: 132 days median2022: 168 days median2023: 119 days median2024: 266 days median2025: 125 days median2026 (partial year): 176 days median
2007high 266 (2024) · low 73 (2017)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · OBP

1in 2018

2009: 12018: 12026 (partial year): 1
2007high 1 (2009) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · OBP

81in 2025

2009: 32011: 52012: 32013: 12015: 32016: 62017: 32018: 62019: 122020: 122021: 152022: 592023: 432024: 502025: 81
2007high 81 (2025) · low 0 (2007)2025

MAUDE reports naming product code OBP, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20082—00
20090—13
20100—00
20110—05
20120—03
20132—01
20141—00
20152—03
2016310106
201787303
2018414416
20193156012
20201—012
20215132015
20226168059
20237119043
20245266050
202512125081
202681761—

What is it indicated for?

BTL-995-rTMS is indicated to be used for the treatment of Major Depressive Disorder in adult patients who have failed to achieve satisfactory improvement from prior antidepressant medication in the current episode.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K212723: BTL-995-rTMS.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K212723

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026