510(k) Report

510(k) · Cleared

Cleared

ES1 System

K213102510(k) TraditionalCleared Jan 11, 2022109-day reviewClass II21 CFR 892.1550

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

E-Scopics · IYN System, Imaging, Pulsed Doppler, Ultrasonic

Cleared on Jan 11, 2022 as substantially equivalent to K203273 (Echosens, 2021) after a 109-day review. Its family tree reaches back 23 generations to 1995. 3 later devices descend from it.

Decided
Jan 11, 2022
Review
109 days
Class
Class II
Product code
IYN
Recalls
None
Predicates
1

Its longest line of descent runs back 23 generations to K935595 (1995). 162 ancestors in all, the oldest K894632 (1989). 3 later devices descend from it, 1 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2015: 1 other ancestor2013: 3 other ancestors2012: 2 other ancestors2010: 2 other ancestors2009: 2 other ancestors2006: 9 other ancestors2004: 14 other ancestors2003: 13 other ancestors2002: 11 other ancestors2008: 8 other ancestors2005: 10 other ancestors2000: 7 other ancestors1999: 11 other ancestors1997: 9 other ancestors2001: 7 other ancestors1995: 8 other ancestors2011: 1 other ancestor1998: 4 other ancestors1992: 2 other ancestors2007: 3 other ancestors1994: 6 other ancestors1989: 2 other ancestors1996: 3 other ancestors1993: 1 other ancestor2023: 1 descendant cleared2026: 2 descendants clearedReference device: K191007 · Aixplorer MACH 30, Aixplorer MACH 20 Ultrasound Diagnostic Systems · Supersonic Imagine · 2019K935595 · Acuson Model 3001 · Acuson Corp. · 1995K973767 · Harmonic Imaging with Contrast · Acuson Corp. · 1997K022567 · Sequoia Signature II Diagnostic Ultrasound System · Acuson Corp. · 2002K032114 · Sequoia 8.0 Diagnostic Ultrasound System · Siemens Medical Solutions USA, Inc. · 2003×3: 3 generations cleared close together, K041319 (2004), K042770 (2004), K050240 (2005) K052894 · Sonoline G60 S Ultrasound System · Siemens Medical Solutions USA, Inc. · 2005 · recalled×2: 2 generations cleared close together, K063138 (2006), K063803 (2007) K072786 · Acuson S2000 Ultrasound System · Siemens Medical Solutions USA, Inc. · 2007K083095 · Sonixtouch Ultrasound System · Ultrasonix Medical Corporation · 2008K092271 · GE Logiq E9 BT2010 Diagnostic Ultrasound System, Model 5205000-3, 5205000-4 · GE Healthcare · 2009 · recalledK110870 · Aplio Diagnostic Ultrasound System; Aplio Diagnostic Ultrasound System; Aplio Diagnostic Ultrasound System · Toshiba America Medical Systems, In.C · 2011K121422 · Aplio 500/400/300 Diagnostic Ultrasound System · Toshiba Medical Systems Coporation, Japan · 2012K123992 · Aplio 500/400/300 V3.0 · Toshibamedical Systems Corporation · 2013K133761 · Aplio 500/400/300 Diagnostic Ultrasound System V4.0 · Toshibamedical Systems Corporation · 2014K142517 · SoftVue · Delphinus Medical Technologies, Inc. · 2014K150949 · FibroScan · Echosens · 2015K160524 · FibroScan 530 Compact · Echosens · 2016K173034 · FibroScan® Family of Products (Models: 502 Touch, 530 Compact, and 430 Mini+) · Echosens · 2017K181547 · FibroScan® Family of Products (Models: 502 Touch, 530 Compact, and 430 Mini+) · Echosens · 2018K203273 · FibroScan® Family of Products (Models: 502 Touch, 530 Compact, 430 Mini+, and 630) · Echosens · 20211990200020102020
Other ancestors, by generationDescendants, by generation 3 generations back: 1 other ancestor4 generations back: 2 other ancestors5 generations back: 2 other ancestors6 generations back: 3 other ancestors7 generations back: 7 other ancestors8 generations back: 11 other ancestors9 generations back: 10 other ancestors10 generations back: 10 other ancestors11 generations back: 11 other ancestors12 generations back: 14 other ancestors13 generations back: 23 other ancestors14 generations back: 18 other ancestors15 generations back: 6 other ancestors16 generations back: 3 other ancestors17 generations back: 3 other ancestors18 generations back: 8 other ancestors19 generations back: 5 other ancestors20 generations back: 2 other ancestors 1 generation forward: 1 descendant2 generations forward: 2 descendants K203273 · FibroScan® Family of Products (Models: 502 Touch, 530 Compact, 430 Mini+, and 630) · Echosens · 2021K181547 · FibroScan® Family of Products (Models: 502 Touch, 530 Compact, and 430 Mini+) · Echosens · 2018K173034 · FibroScan® Family of Products (Models: 502 Touch, 530 Compact, and 430 Mini+) · Echosens · 2017K160524 · FibroScan 530 Compact · Echosens · 2016K150949 · FibroScan · Echosens · 2015K142517 · SoftVue · Delphinus Medical Technologies, Inc. · 2014K133761 · Aplio 500/400/300 Diagnostic Ultrasound System V4.0 · Toshibamedical Systems Corporation · 2014K123992 · Aplio 500/400/300 V3.0 · Toshibamedical Systems Corporation · 2013K121422 · Aplio 500/400/300 Diagnostic Ultrasound System · Toshiba Medical Systems Coporation, Japan · 2012K110870 · Aplio Diagnostic Ultrasound System; Aplio Diagnostic Ultrasound System; Aplio Diagnostic Ultrasound System · Toshiba America Medical Systems, In.C · 2011K092271 · GE Logiq E9 BT2010 Diagnostic Ultrasound System, Model 5205000-3, 5205000-4 · GE Healthcare · 2009 · recalledK083095 · Sonixtouch Ultrasound System · Ultrasonix Medical Corporation · 2008K072786 · Acuson S2000 Ultrasound System · Siemens Medical Solutions USA, Inc. · 2007K063803 · Acuson Antares Diagnostic Ultrasound System · Siemens Medical Solutions USA, Inc., Ultrasound DI · 2007 · recalledK063138 · Modification to Acuson Antares Ultrasound System · Siemens Medical Solutions USA, Inc. · 2006K052894 · Sonoline G60 S Ultrasound System · Siemens Medical Solutions USA, Inc. · 2005 · recalledK050240 · Modification to Acuson CV70 Cardiovascular System · Siemens Medical Solutions USA, Inc. · 2005 · recalledK042770 · Modification to Acuson CV70 Cardiovascular System · Siemens Medical Solutions USA, Inc. · 2004 · recalledK041319 · Sequoia Diagnostic Ultrasound System · Siemens Medical Solutions USA, Inc. · 2004K032114 · Sequoia 8.0 Diagnostic Ultrasound System · Siemens Medical Solutions USA, Inc. · 2003K022567 · Sequoia Signature II Diagnostic Ultrasound System · Acuson Corp. · 2002K973767 · Harmonic Imaging with Contrast · Acuson Corp. · 1997K935595 · Acuson Model 3001 · Acuson Corp. · 1995−20−15−10−50
  1. Root · 23 generations backK935595 Acuson Model 3001Acuson Corp. · 1995
  2. 19 generations between
  3. 3 generations backK173034 FibroScan® Family of Products (Models: 502 Touch, 530 Compact, and…Echosens · 2017
  4. 2 generations backK181547 FibroScan® Family of Products (Models: 502 Touch, 530 Compact, and…Echosens · 2018
  5. 1 generation backK203273 FibroScan® Family of Products (Models: 502 Touch, 530 Compact, 430…Echosens · 2021
  6. This deviceK213102 ES1 SystemE-Scopics · 2022
  7. Descendant · cites it directly · 2 of its ownK232336 ES Series V2E-Scopics · 2023
  8. Descendant · 2 generations on · 0 of its ownK260748 ES-SeriesE-Scopics · 2026
  9. Descendant · 2 generations on · 0 of its ownK260589 ES-SeriesE-Scopics · 2026
Show all 23 generations
  1. Root · 23 generations backK935595 Acuson Model 3001Acuson Corp. · 1995
  2. 22 generations backK973767 Harmonic Imaging with ContrastAcuson Corp. · 1997
  3. 21 generations backK022567 Sequoia Signature II Diagnostic Ultrasound SystemAcuson Corp. · 2002
  4. 20 generations backK032114 Sequoia 8.0 Diagnostic Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2003
  5. 19 generations backK041319 Sequoia Diagnostic Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2004
  6. 18 generations backK042770 Modification to Acuson CV70 Cardiovascular SystemSiemens Medical Solutions USA, Inc. · 2004 · Recalled
  7. 17 generations backK050240 Modification to Acuson CV70 Cardiovascular SystemSiemens Medical Solutions USA, Inc. · 2005 · Recalled
  8. 16 generations backK052894 Sonoline G60 S Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2005 · Recalled
  9. 15 generations backK063138 Modification to Acuson Antares Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2006
  10. 14 generations backK063803 Acuson Antares Diagnostic Ultrasound SystemSiemens Medical Solutions USA, Inc., Ultrasound DI · 2007 · Recalled
  11. 13 generations backK072786 Acuson S2000 Ultrasound SystemSiemens Medical Solutions USA, Inc. · 2007
  12. 12 generations backK083095 Sonixtouch Ultrasound SystemUltrasonix Medical Corporation · 2008
  13. 11 generations backK092271 GE Logiq E9 BT2010 Diagnostic Ultrasound System, Model 5205000-3…GE Healthcare · 2009 · Recalled
  14. 10 generations backK110870 Aplio Diagnostic Ultrasound System; Aplio Diagnostic Ultrasound…Toshiba America Medical Systems, In.C · 2011
  15. 9 generations backK121422 Aplio 500/400/300 Diagnostic Ultrasound SystemToshiba Medical Systems Coporation, Japan · 2012
  16. 8 generations backK123992 Aplio 500/400/300 V3.0Toshibamedical Systems Corporation · 2013
  17. 7 generations backK133761 Aplio 500/400/300 Diagnostic Ultrasound System V4.0Toshibamedical Systems Corporation · 2014
  18. 6 generations backK142517 SoftVueDelphinus Medical Technologies, Inc. · 2014
  19. 5 generations backK150949 FibroScanEchosens · 2015
  20. 4 generations backK160524 FibroScan 530 CompactEchosens · 2016
  21. 3 generations backK173034 FibroScan® Family of Products (Models: 502 Touch, 530 Compact, and…Echosens · 2017
  22. 2 generations backK181547 FibroScan® Family of Products (Models: 502 Touch, 530 Compact, and…Echosens · 2018
  23. 1 generation backK203273 FibroScan® Family of Products (Models: 502 Touch, 530 Compact, 430…Echosens · 2021
  24. This deviceK213102 ES1 SystemE-Scopics · 2022

Most influential descendants

Showing 3 of 3 · See all
  • K232336ES Series V2E-Scopics · 2023 · cites it directly2descendants
  • K260748ES-SeriesE-Scopics · 2026 · 2 generations on0descendants
  • K260589ES-SeriesE-Scopics · 2026 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−23K935595Acuson Model 3001Acuson Corp.1995—
−22K973767Harmonic Imaging with ContrastAcuson Corp.1997—
−21K022567Sequoia Signature II Diagnostic Ultrasound SystemAcuson Corp.2002—
−20K032114Sequoia 8.0 Diagnostic Ultrasound SystemSiemens Medical Solutions USA, Inc.2003—
−19K041319Sequoia Diagnostic Ultrasound SystemSiemens Medical Solutions USA, Inc.2004—
−18K042770Modification to Acuson CV70 Cardiovascular SystemSiemens Medical Solutions USA, Inc.20041
−17K050240Modification to Acuson CV70 Cardiovascular SystemSiemens Medical Solutions USA, Inc.20051
−16K052894Sonoline G60 S Ultrasound SystemSiemens Medical Solutions USA, Inc.20051
−15K063138Modification to Acuson Antares Ultrasound SystemSiemens Medical Solutions USA, Inc.2006—
−14K063803Acuson Antares Diagnostic Ultrasound SystemSiemens Medical Solutions USA, Inc., Ultrasound DI20079
−13K072786Acuson S2000 Ultrasound SystemSiemens Medical Solutions USA, Inc.2007—
−12K083095Sonixtouch Ultrasound SystemUltrasonix Medical Corporation2008—
−11K092271GE Logiq E9 BT2010 Diagnostic Ultrasound System, Model 5205000-3, 5205000-4GE Healthcare20091
−10K110870Aplio Diagnostic Ultrasound System; Aplio Diagnostic Ultrasound System; Aplio…Toshiba America Medical Systems, In.C2011—
−9K121422Aplio 500/400/300 Diagnostic Ultrasound SystemToshiba Medical Systems Coporation, Japan2012—
−8K123992Aplio 500/400/300 V3.0Toshibamedical Systems Corporation2013—
−7K133761Aplio 500/400/300 Diagnostic Ultrasound System V4.0Toshibamedical Systems Corporation2014—
−6K142517SoftVueDelphinus Medical Technologies, Inc.2014—
−5K150949FibroScanEchosens2015—
−4K160524FibroScan 530 CompactEchosens2016—
−3K173034FibroScan® Family of Products (Models: 502 Touch, 530 Compact, and 430 Mini+)Echosens2017—
−2K181547FibroScan® Family of Products (Models: 502 Touch, 530 Compact, and 430 Mini+)Echosens2018—
−1K203273FibroScan® Family of Products (Models: 502 Touch, 530 Compact, 430 Mini+, and…Echosens2021—
0 (this device)K213102ES1 SystemE-Scopics2022—
+1K232336ES Series V2E-Scopics2023—
+2K260748ES-SeriesE-Scopics2026—
+2K260589ES-SeriesE-Scopics2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198920
199220
199310
199460
199580
199630
199790
199840
1999110
200070
200170
2002110
2003130
2004140
2005100
200690
200730
200880
200920
201020
201110
201220
201330
201510

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202310
202620
FIG. 1 — Lineage of K213102, 1995–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in IYN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new IYN device

  1. #1 K240850 EPIQ Series Diagnostic Ultrasound Systems…score 32.1 · 24 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K203273FibroScan® Family of Products (Models: 502 Touch, 530 Compact, 430 Mini+, and 630)
Summary page 5
…and information supplied in this submission demonstrates substantial equivalence to their respective predicate devices : Predicate Device: FibroScan® Family of Products (K203273), cleared on 03/25/2021. Reference Devices: AIXPLORER® MACH 20 & 30 Ultrasound Diagnostic Systems (K191007), cleared on 10/25/201…
Echosens2021—
†K191007Aixplorer MACH 30, Aixplorer MACH 20 Ultrasound Diagnostic SystemsSupersonic Imagine2019—

Also cleared against K203273: 2 other devices →

What descends from it? (3)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K232336ES Series V2E-Scopics20232

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 27 years and passes through 11 companies; a new generation was cleared every 10 months on median.
  • 33 of the 162 ancestors have a recall of any class.
  • Of its descendants, K232336 (E-Scopics, 2023) has gone furthest, with 2 descendants of its own.
  • 2 other devices also cite its predicate K203273.

How does its category compare?

All IYN devices

IYN System, Imaging, Pulsed Doppler, Ultrasonic: FDA decisions, review times, recalls and adverse event reports over 20 years. 2022, this device’s year, is highlighted.

FDA decisions per year · IYN

57in 2025

2007: 132008: 252009: 182010: 292011: 392012: 432013: 512014: 562015: 542016: 602017: 642018: 592019: 472020: 572021: 462022: 532023: 442024: 502025: 572026 (partial year): 44
2007high 64 (2017) · low 13 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · IYN

124in 2025

2007: 26 days median2008: 18 days median2009: 29 days median2010: 67 days median2011: 46 days median2012: 37 days median2013: 60 days median2014: 39 days median2015: 55 days median2016: 56 days median2017: 83 days median2018: 85 days median2019: 79 days median2020: 72 days median2021: 105 days median2022: 105 days median2023: 115 days median2024: 119 days median2025: 124 days median2026 (partial year): 107 days median
2007high 124 (2025) · low 18 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · IYN

10in 2025

2007: 162008: 122009: 82010: 102011: 82012: 32013: 82014: 22015: 32016: 22018: 72020: 42021: 82022: 102023: 42024: 12025: 102026 (partial year): 2, 1 Class I
2007high 16 (2007) · low 0 (2017)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · IYN

610in 2025

2007: 32008: 22009: 92010: 172011: 182012: 202013: 182014: 482015: 1162016: 1452017: 1462018: 852019: 592020: 672021: 2132022: 1862023: 2292024: 2662025: 610
2007high 610 (2025) · low 2 (2008)2025

MAUDE reports naming product code IYN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071326163
20082518122
2009182989
201029671017
20113946818
20124337320
20135160818
20145639248
201554553116
201660562145
201764830146
20185985785
20194779059
20205772467
2021461058213
20225310510186
2023441154229
2024501191266
20255712410610
2026441072 (1)—

What is it indicated for?

The ES1 Ultrasound Diagnostic System is intended for general purpose pulse echo ultrasound imaging, soft tissue elasticity imaging of the human body and provides measurements of shear wave speed and tissue stiffness, ultrasound beam attenuation and estimates of speed of sound, in internal structures of the body. This device is intended to be used by trained healthcare professionals, in a healthcare environment. The ES1 Ultrasound Diagnostic System is…

Read the full statement (199 words)

The ES1 Ultrasound Diagnostic System is intended for general purpose pulse echo ultrasound imaging, soft tissue elasticity imaging of the human body and provides measurements of shear wave speed and tissue stiffness, ultrasound beam attenuation and estimates of speed of sound, in internal structures of the body. This device is intended to be used by trained healthcare professionals, in a healthcare environment.

The ES1 Ultrasound Diagnostic System is indicated for imaging of anatomical structures in the abdomen and measurements of physical properties in the liver and the spleen.

In particular, the ES1 ultrasound diagnostic system is intended to provide:

- Linear distance measurements of anatomical structures,

- Measurement of shear wave speed at selected shear wave frequencies, and estimates of tissue stiffness in the liver and the spleen,

- Estimates of ultrasound attenuation coefficient in the liver at 3.5 MHz,

- Measurement of brightness ratio between structures and in particular between the liver and the kidney,

- Estimates of speed of sound in the liver.

The shear wave speed measurements, ultrasound beam attenuation, elastic properties estimates, brightness ratio may be used as an aid to the diagnosis, monitoring and clinical management of adult and pediatric patients with liver disease.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K213102: ES1 System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K213102

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026