510(k) · Cleared
ClearedMedicloseTM System
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Health Value Creation B.V., Trading AS Corporis Medical · OCW Endoscopic Tissue Approximation Device
Cleared on Aug 31, 2023 as substantially equivalent to K132362 (Teleflexmedical, Inc., 2013) after a 700-day review. Its family tree reaches back 2 generations to 2010.
- Decided
- Aug 31, 2023
- Review
- 700 days
- Class
- Class II
- Product code
- OCW
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 2 generations to K103412 (2010). No later device cites it as a predicate yet.
View FIG. 1 as a table
Line of descent and top descendants
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in OCW? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new OCW device
- #1 K252400 Endomina EZFuse systemscore 12.0 · 5 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K132362 | Weck Efx Endo Fascial Closure SystemSummary page 4…comparison with the MedicloseTM is: Predicate Device: WECK EFX Endo Fascial Closure System Sponsor: Teleflex Medical, Inc. 510(k) Number: K132362 Clearance Date: 8 October 2013 FDA Product Code: OCW, GCJ, HCF Classification Name: Endoscopic tissue approximat… | 2013 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 13 years and passes through 3 companies; a new generation was cleared every 9.9 years on median.
- None of the 2 ancestors has a recall.
- 3 other devices also cite its predicate K132362.
How does its category compare?
All OCW devicesOCW Endoscopic Tissue Approximation Device: FDA decisions, review times, recalls and adverse event reports over 20 years. 2023, this device’s year, is highlighted.
FDA decisions per year · OCW
1in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · OCW
133in 2023
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · OCW
3so far in 2026, the most since 2007
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · OCW
326in 2025
MAUDE reports naming product code OCW, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 5 | 58 | 0 | 9 |
| 2008 | 4 | 70 | 0 | 47 |
| 2009 | 3 | 30 | 0 | 30 |
| 2010 | 4 | 91 | 0 | 10 |
| 2011 | 1 | — | 0 | 16 |
| 2012 | 1 | — | 0 | 28 |
| 2013 | 2 | — | 0 | 2 |
| 2014 | 0 | — | 0 | 28 |
| 2015 | 0 | — | 0 | 59 |
| 2016 | 2 | — | 0 | 74 |
| 2017 | 2 | — | 0 | 420 |
| 2018 | 2 | — | 0 | 413 |
| 2019 | 1 | — | 0 | 291 |
| 2020 | 1 | — | 0 | 183 |
| 2021 | 3 | 221 | 0 | 198 |
| 2022 | 0 | — | 0 | 235 |
| 2023 | 3 | 133 | 1 | 227 |
| 2024 | 0 | — | 0 | 211 |
| 2025 | 1 | — | 0 | 326 |
| 2026 | 2 | — | 3 | — |
What is it indicated for?
The MedicloseTM System is a single-use suturing device indicated for approximation of tissues and percutaneous suturing of port-site fascia wounds following laparoscopic surgery.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K213271 · printed Nov 6, 2026
Cite this page
510(k) Report. “K213271: MedicloseTM System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K213271
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026