510(k) Report

510(k) · Cleared

Cleared

BPG ChemoPlus Nitrile Patient Examination Gloves, Powder Free

K213408510(k) TraditionalCleared Apr 17, 2022180-day reviewClass I21 CFR 880.6250

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Meditech Gloves Sdn Bhd · LZA Polymer Patient Examination Glove

Cleared on Apr 17, 2022 as substantially equivalent to K192954 (Comfort Rubber Gloves Industries Sdn. Bhd., 2020) after a 180-day review. Its family tree reaches back 2 generations to 2019. 3 later devices descend from it.

Decided
Apr 17, 2022
Review
180 days
Class
Class I
Product code
LZA
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K183287 (2019). 3 later devices descend from it, 1 citing it directly.

  1. Root · 2 generations backK183287 Powder Free Nitrile Patient Examination Glove, Blue Colored…Kossan International Sdn Bhd · 2019
  2. 1 generation backK192954 Power Free Nitrile Examination Gloves Tested for Use with…Comfort Rubber Gloves Industries Sdn. Bhd. · 2020
  3. This deviceK213408 BPG ChemoPlus Nitrile Patient Examination Gloves, Powder FreeMeditech Gloves Sdn Bhd · 2022
  4. Descendant · cites it directly · 2 of its ownK230121 Nitrile Examination Gloves Powder Free Tested For Use With…Careglove Global Sdn. Bhd. · 2023
  5. Descendant · 2 generations on · 0 of its ownK250578 Nitrile Examination Gloves Powder Free Tested for Use With…Careglove Global Sdn. Bhd. · 2025
  6. Descendant · 2 generations on · 0 of its ownK232252 Nitrile Powder Free Examination Gloves Tested for Use with…Dehai (Shandong) Medical Gloves, Co., Ltd. · 2023

Most influential descendants

Showing 3 of 3 · See all
  • K230121Nitrile Examination Gloves Powder Free Tested For Use With Chemotherapy Drugs & Fentanyl…Careglove Global Sdn. Bhd. · 2023 · cites it directly2descendants
  • K250578Nitrile Examination Gloves Powder Free Tested for Use With Chemotherapy Drugs & Fentanyl…Careglove Global Sdn. Bhd. · 2025 · 2 generations on0descendants
  • K232252Nitrile Powder Free Examination Gloves Tested for Use with Chemotherapy Drugs and…Dehai (Shandong) Medical Gloves, Co., Ltd. · 2023 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K183287Powder Free Nitrile Patient Examination Glove, Blue Colored, Non-Sterile…Kossan International Sdn Bhd2019—
−1K192954Power Free Nitrile Examination Gloves Tested for Use with Chemotherapy Drugs…Comfort Rubber Gloves Industries Sdn. Bhd.2020—
0 (this device)K213408BPG ChemoPlus Nitrile Patient Examination Gloves, Powder FreeMeditech Gloves Sdn Bhd2022—
+1K230121Nitrile Examination Gloves Powder Free Tested For Use With Chemotherapy Drugs…Careglove Global Sdn. Bhd.2023—
+2K250578Nitrile Examination Gloves Powder Free Tested for Use With Chemotherapy Drugs…Careglove Global Sdn. Bhd.2025—
+2K232252Nitrile Powder Free Examination Gloves Tested for Use with Chemotherapy Drugs…Dehai (Shandong) Medical Gloves, Co., Ltd.2023—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202320
202510
FIG. 1 — Lineage of K213408, 2019–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LZA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LZA device

  1. #1 K192333 Blue Nitrile Examination Gloves Powder Freescore 71.0 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K192954Power Free Nitrile Examination Gloves Tested for Use with Chemotherapy Drugs and Fentanyl
Summary page 5
…ored, Powder Free Nitrile Examination Gloves, Non-sterile, and Tested for Use with Chemotherapy Drugs and Fentanyl Citrate 510(k) : K192954 Regulatory : Class I Product Code : LZA, LZC, QDO 4.0 Description of…
Comfort Rubber Gloves Industries Sdn. Bhd.2020—

Also cleared against K192954: 10 other devices →

What descends from it? (3)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K230121Nitrile Examination Gloves Powder Free Tested For Use With Chemotherapy Drugs & Fentanyl…Careglove Global Sdn. Bhd.20232

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 3 years and passes through 3 companies; a new generation was cleared every 1.8 years on median.
  • None of the 2 ancestors has a recall.
  • Of its descendants, K230121 (Careglove Global Sdn. Bhd., 2023) has gone furthest, with 2 descendants of its own.
  • 10 other devices also cite its predicate K192954.

How does its category compare?

All LZA devices

LZA Polymer Patient Examination Glove: FDA decisions, review times, recalls and adverse event reports over 20 years. 2022, this device’s year, is highlighted.

FDA decisions per year · LZA

24in 2025

2007: 212008: 182009: 282010: 312011: 262012: 332013: 202014: 272015: 202016: 302017: 442018: 222019: 252020: 302021: 1392022: 1462023: 622024: 302025: 242026 (partial year): 15
2007high 146 (2022) · low 18 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LZA

110in 2025

2007: 95 days median2008: 97 days median2009: 112 days median2010: 97 days median2011: 122 days median2012: 110 days median2013: 130 days median2014: 197 days median2015: 112 days median2016: 171 days median2017: 124 days median2018: 178 days median2019: 212 days median2020: 101 days median2021: 111 days median2022: 111 days median2023: 92 days median2024: 89 days median2025: 110 days median2026 (partial year): 103 days median
2007high 212 (2019) · low 89 (2024)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LZA

3so far in 2026, the most since 2007

2015: 12016: 12026 (partial year): 3
2007high 3 (2026) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LZA

73in 2025

2007: 72008: 22009: 122010: 122011: 92012: 112013: 102014: 82015: 122016: 252017: 42018: 32019: 212020: 42021: 202022: 192023: 242024: 762025: 73
2007high 76 (2024) · low 2 (2008)2025

MAUDE reports naming product code LZA, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007219507
2008189702
200928112012
20103197012
20112612209
201233110011
201320130010
20142719708
201520112112
201630171125
20174412404
20182217803
201925212021
20203010104
2021139111020
2022146111019
20236292024
20243089076
202524110073
2026151033—

What is it indicated for?

A patient examination glove is a disposable device intended for medical purposes that is worn on the examiner's hand or finger to prevent contamination between patient and examiner. These gloves were tested for use with chemotherapy drugs and Fentanyl Citrate per ASTM D6978-05 (Reapproved 2019) Standard Practice for Assessment of Medical Gloves to Permeation by Chemotherapy Drugs. Chemotherapy Drug and Concentration Minimum Breakthrough Detection Time…

Read the full statement (239 words)

A patient examination glove is a disposable device intended for medical purposes that is worn on the examiner's hand or finger to prevent contamination between patient and examiner.

These gloves were tested for use with chemotherapy drugs and Fentanyl Citrate per ASTM D6978-05 (Reapproved 2019) Standard Practice for Assessment of Medical Gloves to Permeation by Chemotherapy Drugs.

Chemotherapy Drug and Concentration Minimum Breakthrough Detection Time (Minutes)

Azacitidine, 25mg/ml (25,000 ppm) >240mins

Bleomycin Sulphate 15mg/ml (15,000 ppm) >240mins

Carboplatin 10mg/ml (10,000 ppm) >240mins

Carmustine (BCNU) 3.3mg/ml (3300 ppm) 22.5mins

Cetuximab 2mg/ml (2000 ppm) >240mins

Cisplatin Img/ml (1000 ppm) >240mins

Cyclophosphamide (Cytoxan) 20mg/ml (20,000 ppm) >240mins

Dacarbazine 10mg/ml (10,000 ppm) >240mins

Docetaxel 10mg/ml (10,000 ppm) >240mins

Doxorubicin HCI 2mg/ml (2,000 ppm) >240mins

Ellence (Epirubicin) 2mg/ml (2,000 ppm) >240mins

Etoposide 20mg/ml (20,000 ppm) >240mins

Fluorouracil 50mg/ml (50,000 ppm) >240mins

Gemcitabine 38mg/ml (38,000 ppm) >240mins

Ifosfamide 50mg/ml (50,000 ppm) >240mins

Irinotecan 20mg/ml (20,000 ppm) >240mins

Methotrexate 25mg/ml (25,000ppm) >240mins

Mitomycin C 0.5mg/ml (500 ppm) >240mins

Mitoxantrone 2mg/ml (2,000 ppm) >240mins

Oxaliplatin 2mg/ml (2,000ppm) >240mins

Paclitaxel 6mg/ml (6,000 ppm) >240mins

Rituximab 10mg/ml (10,000 ppm) >240mins

Thio Tepa 10 mg/ml (10,000 ppm) 36.1 mins

Vincristine Sulfate 1mg/ml 1,000 ppm) >240mins

Vinorelbine 10mg/ml (10,000 ppm) >240mins

Tested for Fentanyl Citrate is as follows:

Fentanyl Citrate 100mcg/2ml ~ >240mins

Please note the following drugs have low permeation times

Camustine (BCNU) 3.3mg/ml 22.5mins

Thio Tepa 10mg/ml 36.1mins

Warning: Do not use these gloves with Camustine or Thio Tepa.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K213408: BPG ChemoPlus Nitrile Patient Examination Gloves, Powder Free.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K213408

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026