510(k) Report

510(k) · Cleared

Cleared

DERMABOND PRINEO Skin Closure System

K213512510(k) SpecialCleared Dec 7, 202135-day reviewClass II21 CFR 878.4011

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

ETHICON, Inc. · OMD Cutaneous Tissue Adhesive With Mesh

Cleared on Dec 7, 2021 as substantially equivalent to K133864 (ETHICON, Inc., 2014) after a 35-day review. Its family tree reaches back 2 generations to 2010.

Decided
Dec 7, 2021
Review
35 days
Class
Class II
Product code
OMD
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to DEN090005 (2010). No later device cites it as a predicate yet.

  1. Root · 2 generations backDEN090005 Prineo Skin Closure SystemClosure Medical Corp. · 2010
  2. 1 generation backK133864 Dermabond Prineo Skin Closure SystemETHICON, Inc. · 2014 · Recalled
  3. This deviceK213512 DERMABOND PRINEO Skin Closure SystemETHICON, Inc. · 2021
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2DEN090005Prineo Skin Closure SystemClosure Medical Corp.2010—
−1K133864Dermabond Prineo Skin Closure SystemETHICON, Inc.20141
0 (this device)K213512DERMABOND PRINEO Skin Closure SystemETHICON, Inc.2021—
FIG. 1 — Lineage of K213512, 2010–2021Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in OMD? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new OMD device

  1. #1 K233460 CM00622 LINC Skin Closure System (CM00622 LINC)score 8.0 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K133864Dermabond Prineo Skin Closure System
Summary page 4
…de: OMD Date Prepared: December 06, 2021 Legally Marketed Predicate Devices: Predicate # Predicate Trade Name (Primary Predicate is listed first) Product Code K133864 DERMABOND™ PRINEO™ Skin Closure System OMD Device Description: DERMABOND™ PRINEO™ Skin Closure Syst…
ETHICON, Inc.20141

Also cleared against K133864: 5 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 11 years and passes through 2 companies; a new generation was cleared every 7.7 years on median.
  • 1 of the 2 ancestors has a recall of any class.
  • 5 other devices also cite its predicate K133864.

How does its category compare?

All OMD devices

OMD Cutaneous Tissue Adhesive With Mesh: FDA decisions, review times, recalls and adverse event reports over 20 years. 2021, this device’s year, is highlighted.

FDA decisions per year · OMD

1in 2024

2010: 12014: 12015: 12017: 22020: 12021: 12022: 12024: 1
2007high 2 (2017) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · OMD

Too few OMD 510(k)s in any year since 2007 to give a median.

Recalls per year · OMD

No recall names OMD since 2007.

Adverse event reports per year · OMD

288in 2025

2012: 252013: 542014: 172015: 942016: 1252017: 1632018: 2062019: 1532020: 862021: 1862022: 1752023: 1712024: 2562025: 288
2007high 288 (2025) · low 0 (2007)2025

MAUDE reports naming product code OMD, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20101—00
20110—00
20120—025
20130—054
20141—017
20151—094
20160—0125
20172—0163
20180—0206
20190—0153
20201—086
20211—0186
20221—0175
20230—0171
20241—0256
20250—0288
20260—0—

What is it indicated for?

DERMABOND™ PRINEO™ System is intended for topical application only to hold closed easily approximated skin edges of wounds from surgical incisions, including punctures from minimally invasive surgery, and simple, thoroughly cleansed, trauma-induced lacerations. DERMABOND™ PRINEO™ System should be used in conjunction with, but not in place of, deep dermal stitches. Additionally, the adjunct wound closure device component maintains temporary skin edge alignment along the length of the wound during application of the liquid adhesive.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K213512: DERMABOND PRINEO Skin Closure System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K213512

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026