510(k) Report

510(k) · Cleared

Cleared

Rune Labs Tremor Transducer System

K213519510(k) TraditionalCleared Jun 10, 2022219-day reviewClass II21 CFR 882.1950

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Rune Labs, Inc. · GYD Transducer, Tremor

Cleared on Jun 10, 2022 as substantially equivalent to K140086 (Gkc Manufacturing Pty, Ltd., 2014) after a 219-day review. Its family tree reaches back 6 generations to 1986. 4 later devices descend from it.

Decided
Jun 10, 2022
Review
219 days
Class
Class II
Product code
GYD
Recalls
None
Predicates
1

Its longest line of descent runs back 6 generations to K854030 (1986). 15 ancestors in all. 4 later devices descend from it, 2 citing it directly.

Other ancestors, by generationDescendants, by generation 2 generations back: 3 other ancestors3 generations back: 3 other ancestors4 generations back: 2 other ancestors5 generations back: 1 other ancestor 1 generation forward: 2 descendants2 generations forward: 2 descendants K140086 · Personal Kinetigraph (PKG) System · Gkc Manufacturing Pty, Ltd. · 2014K080545 · Actitrainer · Actigraph, LLC · 2008K040554 · Actigraph, Model AM7164-2.2 and Actigraph with Extended Memory, Model AM71256 · Manufacturing Technology, Inc. · 2004K992410 · Actitrac · Individual Monitoring Systems, Inc. · 1999K983533 · Actiwatch · Mini-Mitter Co., Inc. · 1999 · recalledK854030 · Wrist Actigraph · Ambulatory Monitoring, Inc. · 1986−50
  1. Root · 6 generations backK854030 Wrist ActigraphAmbulatory Monitoring, Inc. · 1986
  2. 5 generations backK983533 ActiwatchMini-Mitter Co., Inc. · 1999 · Recalled
  3. 4 generations backK992410 ActitracIndividual Monitoring Systems, Inc. · 1999
  4. 3 generations backK040554 Actigraph, Model AM7164-2.2 and Actigraph with Extended Memory…Manufacturing Technology, Inc. · 2004
  5. 2 generations backK080545 ActitrainerActigraph, LLC · 2008
  6. 1 generation backK140086 Personal Kinetigraph (PKG) SystemGkc Manufacturing Pty, Ltd. · 2014
  7. This deviceK213519 Rune Labs Tremor Transducer SystemRune Labs, Inc. · 2022
  8. Descendant · cites it directly · 3 of its ownK220820 Parky AppH2o Bilisim Yazilim · 2022
  9. Descendant · 2 generations on · 1 of its ownK250153 Neu PlatformNeuhealth Digital, Ltd. · 2025
  10. Descendant · 2 generations on · 0 of its ownK262515 Kneu Platform (V2)Kneu Health Digital, Ltd. · 2026
  11. Descendant · cites it directly · 0 of its ownK253055 Sine Monitoring Parkinson’s Disease Tremor Dyskinesia Apple Watch…Nordic Kinetics AB · 2026

Most influential descendants

Showing 4 of 4 · See all
  • K220820Parky AppH2o Bilisim Yazilim · 2022 · cites it directly3descendants
  • K250153Neu PlatformNeuhealth Digital, Ltd. · 2025 · 2 generations on1descendant
  • K262515Kneu Platform (V2)Kneu Health Digital, Ltd. · 2026 · 2 generations on0descendants
  • K253055Sine Monitoring Parkinson’s Disease Tremor Dyskinesia Apple Watch (“SMPDTDAW”)Nordic Kinetics AB · 2026 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K854030Wrist ActigraphAmbulatory Monitoring, Inc.1986—
−5K983533ActiwatchMini-Mitter Co., Inc.19993
−4K992410ActitracIndividual Monitoring Systems, Inc.1999—
−3K040554Actigraph, Model AM7164-2.2 and Actigraph with Extended Memory, Model AM71256Manufacturing Technology, Inc.2004—
−2K080545ActitrainerActigraph, LLC2008—
−1K140086Personal Kinetigraph (PKG) SystemGkc Manufacturing Pty, Ltd.2014—
0 (this device)K213519Rune Labs Tremor Transducer SystemRune Labs, Inc.2022—
+1K220820Parky AppH2o Bilisim Yazilim2022—
+2K250153Neu PlatformNeuhealth Digital, Ltd.2025—
+2K262515Kneu Platform (V2)Kneu Health Digital, Ltd.2026—
+1K253055Sine Monitoring Parkinson’s Disease Tremor Dyskinesia Apple Watch (“SMPDTDAW”)Nordic Kinetics AB2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199710
199910
200020
200110
200210
200410
200610
200710

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202210
202510
202620
FIG. 1 — Lineage of K213519, 1986–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GYD? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GYD device

  1. #1 K260374 Empatica Health Monitoring Platform for…score 21.5 · 41 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K140086Personal Kinetigraph (PKG) System
Summary page 4
…stem Common Name: Tremor transducer Classification Name: Transducer, Tremor Regulation Number: 882.1950 Product Code: GYD Legally Marketed Predicate Devices Predicate # K140086 Predicate Trade Name: Personal Kinetigraph (PKG) System Product Code: GYD Device Description Summary The Rune Labs Kinematic Sys…
Gkc Manufacturing Pty, Ltd.2014—
†K161717Personal Kinetigraph (PKG) SystemGkc Manufacturing Pty, Ltd.2016—
†DEN180044ECG AppApple, Inc.2018—
†DEN180042Irregular Rhythm Notification FeatureApple, Inc.2018—

Also cleared against K140086: 1 other device →

What descends from it? (4)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K220820Parky AppH2o Bilisim Yazilim20223
K253055Sine Monitoring Parkinson’s Disease Tremor Dyskinesia Apple Watch (“SMPDTDAW”)Nordic Kinetics AB20260

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 36 years and passes through 7 companies; a new generation was cleared every 6.1 years on median.
  • 1 of the 15 ancestors has a recall of any class.
  • Of its descendants, K220820 (H2o Bilisim Yazilim, 2022) has gone furthest, with 3 descendants of its own.
  • 1 other device also cites its predicate K140086.

How does its category compare?

All GYD devices

GYD Transducer, Tremor: FDA decisions, review times, recalls and adverse event reports over 20 years. 2022, this device’s year, is highlighted.

FDA decisions per year · GYD

1in 2025

2007: 12014: 12016: 12022: 32023: 12025: 12026 (partial year): 3
2007high 3 (2022) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GYD

241in 2022

2022: 241 days median2026 (partial year): 190 days median
2007high 241 (2022)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GYD

No recall names GYD since 2007.

Adverse event reports per year · GYD

3in 2023

2023: 3
2007high 3 (2023) · low 0 (2007)2025

MAUDE reports naming product code GYD, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20141—00
20150—00
20161—00
20170—00
20180—00
20190—00
20200—00
20210—00
2022324100
20231—03
20240—00
20251—00
202631900—

What is it indicated for?

The Rune Labs Kinematic System is intended to quantify kinematics of movement disorder symptoms including tremor and dyskinesia, in adults (45 years of age or older) with mild to moderate Parkinson's disease.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K213519: Rune Labs Tremor Transducer System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K213519

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026