510(k) Report

510(k) · Cleared

Cleared

DeGen Navigated Instrumentation

K213918510(k) TraditionalCleared Feb 9, 202256-day reviewClass II21 CFR 882.4560

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Degen Medical · OLO Orthopedic Stereotaxic Instrument

Cleared on Feb 9, 2022 as substantially equivalent to K203816 (Degen Medical, 2021) after a 56-day review. Its family tree reaches back 18 generations to 2004.

Decided
Feb 9, 2022
Review
56 days
Class
Class II
Product code
OLO
Recalls
None
Predicates
1

Its longest line of descent runs back 18 generations to K040583 (2004). 154 ancestors in all, the oldest K841189 (1984). No later device cites it as a predicate yet.

Other ancestors, by year cleared 2014: 2 other ancestors2015: 1 other ancestor2013: 3 other ancestors2011: 2 other ancestors2012: 1 other ancestor2008: 5 other ancestors2006: 8 other ancestors2005: 14 other ancestors2010: 2 other ancestors2009: 1 other ancestor2004: 19 other ancestors2003: 8 other ancestors2001: 9 other ancestors2000: 11 other ancestors1999: 3 other ancestors1997: 5 other ancestors1994: 4 other ancestors2007: 3 other ancestors2002: 8 other ancestors1998: 6 other ancestors1996: 2 other ancestors1995: 7 other ancestors1988: 2 other ancestors1987: 1 other ancestor1992: 2 other ancestors1989: 1 other ancestor1986: 2 other ancestors1984: 2 other ancestors1985: 1 other ancestor1990: 1 other ancestorReference device: K140454 · Navigated CD Horizon Solera Screwdriver/Taps · Medtronic Sofamor Danek USA, Inc. · 2014 · recalled×7: 7 generations cleared close together, K040583 (2004), K041118 (2004), K042025 (2004), K043151 (2005), K050809 (2005), K052187 (2005), K053101 (2006) ×2: 2 generations cleared close together, K091442 (2009), K091974 (2009) K102555 · CD Horizon Spinal System · Medtronic Sofamor Danek USA, Inc. · 2010×2: 2 generations cleared close together, K112473 (2011), K113174 (2011) ×2: 2 generations cleared close together, K121680 (2012), K122862 (2012) K141605 · CD Horizon Spinal System · Medtronic Sofamor Danek USA, Inc. · 2014K143375 · CD HORIZON Spinal System, Medtronic Navigated Reusable Instruments · Medtronic Sofamor Danek USA, Inc. · 2015K172166 · OLYMPIC Navigated Instruments · Astura Medical · 2018K203816 · DeGen Navigated Instrumentation · Degen Medical · 202119801990200020102020
Other ancestors, by generation 2 generations back: 1 other ancestor3 generations back: 4 other ancestors4 generations back: 9 other ancestors5 generations back: 26 other ancestors6 generations back: 46 other ancestors7 generations back: 24 other ancestors8 generations back: 11 other ancestors9 generations back: 8 other ancestors10 generations back: 7 other ancestors K203816 · DeGen Navigated Instrumentation · Degen Medical · 2021K172166 · OLYMPIC Navigated Instruments · Astura Medical · 2018K143375 · CD HORIZON Spinal System, Medtronic Navigated Reusable Instruments · Medtronic Sofamor Danek USA, Inc. · 2015K141605 · CD Horizon Spinal System · Medtronic Sofamor Danek USA, Inc. · 2014K122862 · CD Horizon Spinal System · Medtronic Sofamor Danek USA, Inc. · 2012K121680 · CD Horizon Spinal System · Medtronic Sofamor Danek USA, Inc. · 2012K113174 · CD Horizon Spinal System · Medtronic Sofamor Danek USA, Inc. · 2011 · recalledK112473 · CD Horizon Spinal System · Medtronic Sofamor Danek, Inc. · 2011K102555 · CD Horizon Spinal System · Medtronic Sofamor Danek USA, Inc. · 2010K091974 · Modification to CD Horizon Spinal System · Medtronic Sofamor Danek USA, Inc. · 2009 · recalledK091442 · CD Horizon Spinal System · Medtronic Sofamor Danek · 2009K053101 · CD Horizon Spinal System · Medtronic Sofamor Danek · 2006K052187 · Modification to: CD Horizon Spinal System · Medtronic Sofamor Danek · 2005K050809 · CD Horizon Spinal System · Medtronic Sofamor Danek USA, Inc. · 2005K043151 · Modification to: CD Horizon Spinal System · Medtronic Sofamor Danek · 2005K042025 · Modification to CD Horizon Spinal System · Medtronic Sofamor Danek, Inc. · 2004 · recalledK041118 · Modification to CD Horizon Spinal System · Medtronic Sofamor Danek · 2004K040583 · Modification to: CD Horizon Spinal System · Medtronic Sofamor Danek · 2004−15−10−50
  1. Root · 18 generations backK040583 Modification to: CD Horizon Spinal SystemMedtronic Sofamor Danek · 2004
  2. 14 generations between
  3. 3 generations backK143375 CD HORIZON Spinal System, Medtronic Navigated Reusable InstrumentsMedtronic Sofamor Danek USA, Inc. · 2015
  4. 2 generations backK172166 OLYMPIC Navigated InstrumentsAstura Medical · 2018
  5. 1 generation backK203816 DeGen Navigated InstrumentationDegen Medical · 2021
  6. This deviceK213918 DeGen Navigated InstrumentationDegen Medical · 2022
Show all 18 generations
  1. Root · 18 generations backK040583 Modification to: CD Horizon Spinal SystemMedtronic Sofamor Danek · 2004
  2. 17 generations backK041118 Modification to CD Horizon Spinal SystemMedtronic Sofamor Danek · 2004
  3. 16 generations backK042025 Modification to CD Horizon Spinal SystemMedtronic Sofamor Danek, Inc. · 2004 · Recalled
  4. 15 generations backK043151 Modification to: CD Horizon Spinal SystemMedtronic Sofamor Danek · 2005
  5. 14 generations backK050809 CD Horizon Spinal SystemMedtronic Sofamor Danek USA, Inc. · 2005
  6. 13 generations backK052187 Modification to: CD Horizon Spinal SystemMedtronic Sofamor Danek · 2005
  7. 12 generations backK053101 CD Horizon Spinal SystemMedtronic Sofamor Danek · 2006
  8. 11 generations backK091442 CD Horizon Spinal SystemMedtronic Sofamor Danek · 2009
  9. 10 generations backK091974 Modification to CD Horizon Spinal SystemMedtronic Sofamor Danek USA, Inc. · 2009 · Recalled
  10. 9 generations backK102555 CD Horizon Spinal SystemMedtronic Sofamor Danek USA, Inc. · 2010
  11. 8 generations backK112473 CD Horizon Spinal SystemMedtronic Sofamor Danek, Inc. · 2011
  12. 7 generations backK113174 CD Horizon Spinal SystemMedtronic Sofamor Danek USA, Inc. · 2011 · Recalled
  13. 6 generations backK121680 CD Horizon Spinal SystemMedtronic Sofamor Danek USA, Inc. · 2012
  14. 5 generations backK122862 CD Horizon Spinal SystemMedtronic Sofamor Danek USA, Inc. · 2012
  15. 4 generations backK141605 CD Horizon Spinal SystemMedtronic Sofamor Danek USA, Inc. · 2014
  16. 3 generations backK143375 CD HORIZON Spinal System, Medtronic Navigated Reusable InstrumentsMedtronic Sofamor Danek USA, Inc. · 2015
  17. 2 generations backK172166 OLYMPIC Navigated InstrumentsAstura Medical · 2018
  18. 1 generation backK203816 DeGen Navigated InstrumentationDegen Medical · 2021
  19. This deviceK213918 DeGen Navigated InstrumentationDegen Medical · 2022
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−18K040583Modification to: CD Horizon Spinal SystemMedtronic Sofamor Danek2004—
−17K041118Modification to CD Horizon Spinal SystemMedtronic Sofamor Danek2004—
−16K042025Modification to CD Horizon Spinal SystemMedtronic Sofamor Danek, Inc.20044
−15K043151Modification to: CD Horizon Spinal SystemMedtronic Sofamor Danek2005—
−14K050809CD Horizon Spinal SystemMedtronic Sofamor Danek USA, Inc.2005—
−13K052187Modification to: CD Horizon Spinal SystemMedtronic Sofamor Danek2005—
−12K053101CD Horizon Spinal SystemMedtronic Sofamor Danek2006—
−11K091442CD Horizon Spinal SystemMedtronic Sofamor Danek2009—
−10K091974Modification to CD Horizon Spinal SystemMedtronic Sofamor Danek USA, Inc.20091
−9K102555CD Horizon Spinal SystemMedtronic Sofamor Danek USA, Inc.2010—
−8K112473CD Horizon Spinal SystemMedtronic Sofamor Danek, Inc.2011—
−7K113174CD Horizon Spinal SystemMedtronic Sofamor Danek USA, Inc.20111
−6K121680CD Horizon Spinal SystemMedtronic Sofamor Danek USA, Inc.2012—
−5K122862CD Horizon Spinal SystemMedtronic Sofamor Danek USA, Inc.2012—
−4K141605CD Horizon Spinal SystemMedtronic Sofamor Danek USA, Inc.2014—
−3K143375CD HORIZON Spinal System, Medtronic Navigated Reusable InstrumentsMedtronic Sofamor Danek USA, Inc.2015—
−2K172166OLYMPIC Navigated InstrumentsAstura Medical2018—
−1K203816DeGen Navigated InstrumentationDegen Medical2021—
0 (this device)K213918DeGen Navigated InstrumentationDegen Medical2022—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198420
198510
198620
198710
198820
198910
199010
199220
199440
199570
199620
199750
199860
199930
2000110
200190
200280
200380
2004190
2005140
200680
200730
200850
200910
201020
201120
201210
201330
201420
201510
FIG. 1 — Lineage of K213918, 2004–2022Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in OLO? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new OLO device

  1. #1 K240662 Spine Guidance Software (version 5.0); Xia 3/…score 23.7 · 15 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K203816DeGen Navigated Instrumentation
Summary page 4
…ssification Name Sterotaxic Instrument OLO Code–Classification 21 CFR 882.4560 : Class II Primary Predicate K203816 DeGen Medical Navigated Instrumentation Reference Device K140454 Medtronic Navigated CD Horizon Solera Screwdriver / Taps…
Degen Medical2021—
†K140454Navigated CD Horizon Solera Screwdriver/TapsMedtronic Sofamor Danek USA, Inc.20141

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 18 years and passes through 5 companies; a new generation was cleared every 7 months on median.
  • 21 of the 154 ancestors have a recall of any class.

How does its category compare?

All OLO devices

OLO Orthopedic Stereotaxic Instrument: FDA decisions, review times, recalls and adverse event reports over 20 years. 2022, this device’s year, is highlighted.

FDA decisions per year · OLO

40in 2025

2009: 112010: 92011: 112012: 72013: 72014: 102015: 102016: 142017: 332018: 242019: 352020: 342021: 282022: 402023: 452024: 442025: 402026 (partial year): 42
2007high 45 (2023) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · OLO

119in 2025

2009: 126 days median2010: 113 days median2011: 138 days median2012: 129 days median2013: 137 days median2014: 119 days median2015: 176 days median2016: 120 days median2017: 91 days median2018: 97 days median2019: 95 days median2020: 89 days median2021: 91 days median2022: 89 days median2023: 90 days median2024: 90 days median2025: 119 days median2026 (partial year): 109 days median
2007high 176 (2015) · low 89 (2020)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · OLO

1in 2025

2010: 12011: 12012: 12014: 32015: 22016: 32017: 22018: 12019: 12020: 62022: 52023: 7, 1 Class I2024: 42025: 12026 (partial year): 6
2007high 7 (2023) · low 0 (2007)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · OLO

3,306in 2025

2008: 12009: 42010: 42011: 102012: 602013: 362014: 2452015: 4662016: 7502017: 1,0762018: 1,2302019: 1,5852020: 2,7462021: 1,6962022: 1,5682023: 1,4932024: 2,3532025: 3,306
2007high 3,306 (2025) · low 0 (2007)2025

MAUDE reports naming product code OLO, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—01
20091112604
2010911314
201111138110
20127129160
20137137036
2014101193245
2015101762466
2016141203750
2017339121,076
2018249711,230
2019359511,585
2020348962,746
2021289101,696
2022408951,568
202345907 (1)1,493
2024449042,353
20254011913,306
2026421096—

What is it indicated for?

The DeGen Medical Navigated Instrumentation is intended to be used during the preparation and placement of DeGen Medical F1 MPS and E3 MIS screws during spinal surgery to assist the surgeon in precisely locating anatomical structures in either open or minimally invasive procedures. DeGen Medical Navigated Instrumentation is specifically designed for use with the Medtronic StealthStation® System, which is indicated for any medical condition in which the use of stereotactic surgery may be appropriate, and where reference to a rigid anatomical structure such as vertebra can be identified relative to a CT or MR based model, fluoroscopy images, or digitized landmarks of the anatomy.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K213918: DeGen Navigated Instrumentation.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K213918

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026