510(k) Report

510(k) · Cleared

Cleared

CerebralGo Plus

K213986510(k) TraditionalCleared Apr 13, 2023479-day reviewClass II21 CFR 892.2050

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Yukun (Beijing) Technology Co., Ltd. · QIH Automated Radiological Image Processing Software

Cleared on Apr 13, 2023 as substantially equivalent to K192692 (Brainomix Limited, 2020) after a 479-day review. Its family tree reaches back 13 generations to 1990.

Decided
Apr 13, 2023
Review
479 days
Class
Class II
Product code
QIH
Recalls
None
Predicates
1

Its longest line of descent runs back 13 generations to K896095 (1990). 14 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 13 generations backK896095 Images-on-Call Teleradiology SystemDevices & Services Co. · 1990
  2. 9 generations between
  3. 3 generations backK121447 Ischema View RapidIschemaview, Inc. · 2013
  4. 2 generations backK172477 iSchemaView RAPIDIschemaview, Inc. · 2018
  5. 1 generation backK192692 Brainomix 360 e-CTABrainomix Limited · 2020
  6. This deviceK213986 CerebralGo PlusYukun (Beijing) Technology Co., Ltd. · 2023
Show all 13 generations
  1. Root · 13 generations backK896095 Images-on-Call Teleradiology SystemDevices & Services Co. · 1990
  2. 12 generations backK962699 Radworks Medical Imaging SoftwareApplicare Medical Imaging, B.V. · 1996
  3. 11 generations backK982862 Radworks Medical Imaging Software with Quality Control ModuleApplicare Medical Imaging, B.V. · 1998
  4. 10 generations backK012211 Efilm WorkstationEfilm Medical, Inc. · 2001 · Recalled
  5. 9 generations backK020995 Efilm Workstation with ModulesEfilm Medical, Inc. · 2002 · Recalled
  6. 8 generations backK063539 Nordic Image Control and Evaluation (Nice) Software, Version 2.1Nordicicemedical AS · 2007
  7. 7 generations backK082441 Nordicice SoftwareNordicimaginglab AS · 2008 · Recalled
  8. 6 generations backK090546 Modification to Nordicice SoftwareNordicimaginglab AS · 2009
  9. 5 generations backK111161 Perfscape V2.0Olea Medical · 2011
  10. 4 generations backK120196 Olea SphereOlea Medical · 2012
  11. 3 generations backK121447 Ischema View RapidIschemaview, Inc. · 2013
  12. 2 generations backK172477 iSchemaView RAPIDIschemaview, Inc. · 2018
  13. 1 generation backK192692 Brainomix 360 e-CTABrainomix Limited · 2020
  14. This deviceK213986 CerebralGo PlusYukun (Beijing) Technology Co., Ltd. · 2023
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−13K896095Images-on-Call Teleradiology SystemDevices & Services Co.1990—
−12K962699Radworks Medical Imaging SoftwareApplicare Medical Imaging, B.V.1996—
−11K982862Radworks Medical Imaging Software with Quality Control ModuleApplicare Medical Imaging, B.V.1998—
−10K012211Efilm WorkstationEfilm Medical, Inc.20011
−9K020995Efilm Workstation with ModulesEfilm Medical, Inc.20022
−8K063539Nordic Image Control and Evaluation (Nice) Software, Version 2.1Nordicicemedical AS2007—
−7K082441Nordicice SoftwareNordicimaginglab AS20082
−6K090546Modification to Nordicice SoftwareNordicimaginglab AS2009—
−5K111161Perfscape V2.0Olea Medical2011—
−4K120196Olea SphereOlea Medical2012—
−3K121447Ischema View RapidIschemaview, Inc.2013—
−2K172477iSchemaView RAPIDIschemaview, Inc.2018—
−1K192692Brainomix 360 e-CTABrainomix Limited2020—
0 (this device)K213986CerebralGo PlusYukun (Beijing) Technology Co., Ltd.2023—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199110
FIG. 1 — Lineage of K213986, 1990–2023Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in QIH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new QIH device

  1. #1 K213998 cvi42 Auto Imaging Software Applicationscore 23.6 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K192692Brainomix 360 e-CTA
Summary page 4
…CATE DEVICE Table 1 Predicate device information 510(k) Number Product Code Trade Name Manufacturer K192692 LLZ Brainomix 360°e-CTA Brainomix Limited This predicate device has not been subject t…
Brainomix Limited2020—

Also cleared against K192692: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 33 years and passes through 9 companies; a new generation was cleared every 2.2 years on median.
  • 3 of the 14 ancestors have a recall of any class.
  • 2 other devices also cite its predicate K192692.

How does its category compare?

All QIH devices

QIH Automated Radiological Image Processing Software: FDA decisions, review times, recalls and adverse event reports over 20 years. 2023, this device’s year, is highlighted.

FDA decisions per year · QIH

94in 2025

2019: 22020: 112021: 192022: 252023: 452024: 642025: 942026 (partial year): 78
2007high 94 (2025) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · QIH

150in 2025

2020: 145 days median2021: 125 days median2022: 134 days median2023: 151 days median2024: 141 days median2025: 150 days median2026 (partial year): 130 days median
2007high 151 (2023) · low 125 (2021)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · QIH

1so far in 2026, the most since 2007

2026 (partial year): 1
2007high 1 (2026) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · QIH

4in 2025

2024: 22025: 4
2007high 4 (2025) · low 0 (2007)2025

MAUDE reports naming product code QIH, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20180—00
20192—00
20201114500
20211912500
20222513400
20234515100
20246414102
20259415004
2026781301—

What is it indicated for?

CerebralGo Plus is an image processing software package to be used by trained professionals, including, but not limited to

physicians and medical technicians. The software runs on standard “off-the-shelf” hardware and can be used for image

viewing and processing. Data and images are acquired through DICOM compliant imaging devices.

CerebralGo Plus provides viewing and processing capabilities for imaging datasets acquired with adult's CTA (CT

Angiography).

CerebralGo Plus is not intended for primary diagnostic use.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K213986: CerebralGo Plus.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K213986

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026