510(k) Report

510(k) · Cleared

Cleared

Vista Ophthalmics Vitrectomy Probe

K220030510(k) TraditionalCleared May 4, 2022119-day reviewClass II21 CFR 886.4150

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Vista Ophthalmics, LLC · MLZ Vitrectomy, Instrument Cutter

Cleared on May 4, 2022 as substantially equivalent to K170520 (Alcon Research, Ltd., 2017) after a 119-day review. Its family tree reaches back 9 generations to 1994.

Decided
May 4, 2022
Review
119 days
Class
Class II
Product code
MLZ
Recalls
None
Predicates
1

Its longest line of descent runs back 9 generations to K933880 (1994). 43 ancestors in all, the oldest K844373 (1985). No later device cites it as a predicate yet.

  1. Root · 9 generations backK933880 SL Series Surgical Laser SystemsLaserscope · 1994
  2. 5 generations between
  3. 3 generations backK101285 Constellation Vision SystemAlcon Manufacturing, Ltd. · 2010 · Recalled
  4. 2 generations backK110951 27+ Ultravit Probe, 27+ Flex-Tip Laser Probe, 27+ Endoilluminator…Alcon Research, Ltd. · 2011 · Recalled
  5. 1 generation backK170520 HyperVit Vitrectomy Probe, 23 GA, HyperVit Vitrectomy Probe, 25+…Alcon Research, Ltd. · 2017
  6. This deviceK220030 Vista Ophthalmics Vitrectomy ProbeVista Ophthalmics, LLC · 2022
Show all 9 generations
  1. Root · 9 generations backK933880 SL Series Surgical Laser SystemsLaserscope · 1994
  2. 8 generations backK954905 CB Diode/532 Laser SystemContinuum Biomedical, Inc. · 1996
  3. 7 generations backK964074 Diolite 532Iriderm Div. · 1997
  4. 6 generations backK982031 Oculight GL with the Dermatology HandpieceIridex Corp · 1998
  5. 5 generations backK031665 Iris Medical Oculight GL/GLX Laser SystemsIridex Corp · 2003
  6. 4 generations backK062624 Next Generation LaserAlcon Laboratories · 2007
  7. 3 generations backK101285 Constellation Vision SystemAlcon Manufacturing, Ltd. · 2010 · Recalled
  8. 2 generations backK110951 27+ Ultravit Probe, 27+ Flex-Tip Laser Probe, 27+ Endoilluminator…Alcon Research, Ltd. · 2011 · Recalled
  9. 1 generation backK170520 HyperVit Vitrectomy Probe, 23 GA, HyperVit Vitrectomy Probe, 25+…Alcon Research, Ltd. · 2017
  10. This deviceK220030 Vista Ophthalmics Vitrectomy ProbeVista Ophthalmics, LLC · 2022
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−9K933880SL Series Surgical Laser SystemsLaserscope1994—
−8K954905CB Diode/532 Laser SystemContinuum Biomedical, Inc.1996—
−7K964074Diolite 532Iriderm Div.1997—
−6K982031Oculight GL with the Dermatology HandpieceIridex Corp1998—
−5K031665Iris Medical Oculight GL/GLX Laser SystemsIridex Corp2003—
−4K062624Next Generation LaserAlcon Laboratories2007—
−3K101285Constellation Vision SystemAlcon Manufacturing, Ltd.20104
−2K11095127+ Ultravit Probe, 27+ Flex-Tip Laser Probe, 27+ Endoilluminator Probe, 27+…Alcon Research, Ltd.20111
−1K170520HyperVit Vitrectomy Probe, 23 GA, HyperVit Vitrectomy Probe, 25+, HyperVit…Alcon Research, Ltd.2017—
0 (this device)K220030Vista Ophthalmics Vitrectomy ProbeVista Ophthalmics, LLC2022—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198510
198810
198920
199020
199150
199210
199310
199410
199530
199630
199720
199820
200240
200310
200420
200810
200910
201010
FIG. 1 — Lineage of K220030, 1994–2022Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MLZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K170520HyperVit Vitrectomy Probe, 23 GA, HyperVit Vitrectomy Probe, 25+, HyperVit Vitrectomy…
Summary page 4
…LZ PREDICATE DEVICE: Alcon Hypervit Vitrectomy Probe Alcon, Inc. K170520 REFERENCE DEVICE: Vision Care ProCare Plus Vision Care Devices,…
Alcon Research, Ltd.2017—
†K120170Procare Plus Vitrectomy SystemVisioncare Devices, Inc.2012—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 28 years and passes through 8 companies; a new generation was cleared every 3.0 years on median.
  • 12 of the 43 ancestors have a recall of any class.

How does its category compare?

All MLZ devices

MLZ Vitrectomy, Instrument Cutter: FDA decisions, review times, recalls and adverse event reports over 20 years. 2022, this device’s year, is highlighted.

FDA decisions per year · MLZ

1in 2022

2008: 12010: 12017: 12022: 1
2007high 1 (2008) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MLZ

Too few MLZ 510(k)s in any year since 2007 to give a median.

Recalls per year · MLZ

1in 2025

2025: 1
2007high 1 (2025) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · MLZ

251in 2025

2007: 152008: 52009: 132010: 22011: 12012: 32013: 42014: 22016: 52017: 102018: 82019: 62020: 542021: 402022: 402023: 922024: 1862025: 251
2007high 251 (2025) · low 0 (2015)2025

MAUDE reports naming product code MLZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—015
20081—05
20090—013
20101—02
20110—01
20120—03
20130—04
20140—02
20150—00
20160—05
20171—010
20180—08
20190—06
20200—054
20210—040
20221—040
20230—092
20240—0186
20250—1251
20260—0—

What is it indicated for?

The Vista Ophthalmics vitrectomy probe is intended to be used to remove vitreous and dissect tissue in the eye as follows:

» Vitreous aspiration & cutting

» Membrane cutting & aspiration

* Lens removal

* Dissect tissue in the eye

The Vista Ophthalmics probe is designed as a stand-alone handpiece for use with ophthalmic surgical systems having pneumatically driven vitreoretinal functionality.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K220030: Vista Ophthalmics Vitrectomy Probe.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K220030

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026