510(k) Report

510(k) · Cleared

Cleared

QScreen

K220139510(k) TraditionalCleared Aug 3, 2022197-day reviewClass II21 CFR 882.1900

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Path Medical GmbH · GWJ Stimulator, Auditory, Evoked Response

Cleared on Aug 3, 2022 as substantially equivalent to K133012 (Path Medical GmbH, 2014) after a 197-day review. Its family tree reaches back 6 generations to 1990.

Decided
Aug 3, 2022
Review
197 days
Class
Class II
Product code
GWJ
Recalls
None
Predicates
1

Its longest line of descent runs back 6 generations to K902540 (1990). 26 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 2012: 1 other ancestor2009: 3 other ancestors2007: 1 other ancestor2003: 1 other ancestor2002: 1 other ancestor2000: 2 other ancestors1999: 3 other ancestors1997: 2 other ancestors1995: 2 other ancestors1993: 2 other ancestors1994: 1 other ancestor1991: 1 other ancestorK902540 · Gsi 17 Screening Audiometer · Grason-Stadler, Inc. · 1990K974237 · Gsi 70 Audiopath Screener · Grason-Stadler, Inc. · 1998K982642 · Echo-Screen · Fischer-Zoth Audiologic Systems, Inc. · 1998K013977 · Echo-Screen T, TA, TD, Tda, TC · Fischer-Zoth Audiologic Systems, Inc. · 2002K061744 · Cochlea-Scan / Cochlea-Scan Plus · Bio-Logic Systems Corp. · 2006K133012 · Sentiero · Path Medical GmbH · 2014 · recalled1990199520002005201020152020
  1. Root · 6 generations backK902540 Gsi 17 Screening AudiometerGrason-Stadler, Inc. · 1990
  2. 5 generations backK974237 Gsi 70 Audiopath ScreenerGrason-Stadler, Inc. · 1998
  3. 4 generations backK982642 Echo-ScreenFischer-Zoth Audiologic Systems, Inc. · 1998
  4. 3 generations backK013977 Echo-Screen T, TA, TD, Tda, TCFischer-Zoth Audiologic Systems, Inc. · 2002
  5. 2 generations backK061744 Cochlea-Scan / Cochlea-Scan PlusBio-Logic Systems Corp. · 2006
  6. 1 generation backK133012 SentieroPath Medical GmbH · 2014 · Recalled
  7. This deviceK220139 QScreenPath Medical GmbH · 2022
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K902540Gsi 17 Screening AudiometerGrason-Stadler, Inc.1990—
−5K974237Gsi 70 Audiopath ScreenerGrason-Stadler, Inc.1998—
−4K982642Echo-ScreenFischer-Zoth Audiologic Systems, Inc.1998—
−3K013977Echo-Screen T, TA, TD, Tda, TCFischer-Zoth Audiologic Systems, Inc.2002—
−2K061744Cochlea-Scan / Cochlea-Scan PlusBio-Logic Systems Corp.2006—
−1K133012SentieroPath Medical GmbH20144
0 (this device)K220139QScreenPath Medical GmbH2022—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199110
199320
199410
199520
199720
199930
200020
200210
200310
200710
200930
201210
FIG. 1 — Lineage of K220139, 1990–2022Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in GWJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new GWJ device

  1. #1 K242954 Integrity V500 (Integrity, Integrity with VEMP)score 10.0 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K133012Sentiero
Summary page 4
…Stimulator FDA 21CFR882.1900 & 21CFR874.1050 PREDICATE DEVICE Sentiero 510(k) Number: K133012 DEVICE DESCRIPTION The QScreen is a hand-held and portable audiometric examination device offering test methods for the measur…
Path Medical GmbH20144

Also cleared against K133012: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 32 years and passes through 4 companies; a new generation was cleared every 7.6 years on median.
  • 4 of the 26 ancestors have a recall of any class.
  • 2 other devices also cite its predicate K133012.

How does its category compare?

All GWJ devices

GWJ Stimulator, Auditory, Evoked Response: FDA decisions, review times, recalls and adverse event reports over 20 years. 2022, this device’s year, is highlighted.

FDA decisions per year · GWJ

2in 2024

2007: 22008: 42009: 42010: 12011: 22012: 12013: 22014: 22015: 12017: 22020: 12021: 12022: 12024: 2
2007high 4 (2008) · low 0 (2016)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · GWJ

111in 2009

2008: 64 days median2009: 111 days median
2007high 111 (2009) · low 64 (2008)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · GWJ

1in 2025

2008: 12010: 12019: 12025: 1
2007high 1 (2008) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · GWJ

1in 2025

2010: 22011: 52012: 12013: 12015: 32016: 12017: 432018: 242019: 52020: 32021: 32022: 82023: 62024: 72025: 1
2007high 43 (2017) · low 0 (2007)2025

MAUDE reports naming product code GWJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20072—00
200846410
2009411100
20101—12
20112—05
20121—01
20132—01
20142—00
20151—03
20160—01
20172—043
20180—024
20190—15
20201—03
20211—03
20221—08
20230—06
20242—07
20250—11
20260—0—

What is it indicated for?

The QSCREEN device is a hand-held, portable hearing screener intended for recording and automated evaluation of Otoacoustic Emissions (OAE) and Auditory Brainstem Responses (ABR). Distortion Product Otoacoustic Emission (DPOAE) and Transient Evoked Otoacoustic Emission (TEOAE) tests are applicable to obtain objective evidence of peripheral auditory function. ABR tests are applicable to obtain objective evidence of peripheral and retro-cochlear auditory function including the auditory nerve and the brainstem. QSCREEN is intended to be used in subjects of all ages. It is especially indicated for use in testing individuals for whom behavioral audiometric results are deemed unreliable.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K220139: QScreen.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K220139

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026