510(k) Report

510(k) · Cleared

Cleared

CerroZone Mobile

K220298510(k) TraditionalCleared Jul 1, 2022149-day reviewClass II21 CFR 880.5045

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Cerrozone · FRF Cleaner, Air, Medical Recirculating

Cleared on Jul 1, 2022 as substantially equivalent to K200321 (Novaerus Us, Inc., 2020) after a 149-day review. Its family tree reaches back 3 generations to 1997. 1 later device descends from it.

Decided
Jul 1, 2022
Review
149 days
Class
Class II
Product code
FRF
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to K972064 (1997). 1 later device descends from it, 1 citing it directly.

  1. Root · 3 generations backK972064 Microcon 800MUV, Microcon 400MUV, Microcon Exc-BuvBiological Controls, Inc. · 1997
  2. 2 generations backK070722 Plasmair, Model T2006Airinspace B.V. · 2007
  3. 1 generation backK200321 Novaerus NV1050Novaerus Us, Inc. · 2020
  4. This deviceK220298 CerroZone MobileCerrozone · 2022
  5. Descendant · cites it directly · 0 of its ownK242102 CerroZone MiniCerrozone, LLC · 2024

Most influential descendants

Showing 1 of 1 · See all
  • K242102CerroZone MiniCerrozone, LLC · 2024 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3K972064Microcon 800MUV, Microcon 400MUV, Microcon Exc-BuvBiological Controls, Inc.1997—
−2K070722Plasmair, Model T2006Airinspace B.V.2007—
−1K200321Novaerus NV1050Novaerus Us, Inc.2020—
0 (this device)K220298CerroZone MobileCerrozone2022—
+1K242102CerroZone MiniCerrozone, LLC2024—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202410
FIG. 1 — Lineage of K220298, 1997–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FRF? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FRF device

  1. #1 K200321 Novaerus NV1050score 9.9 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K200321Novaerus NV1050
Summary page 4
…Predicate Device Name / Manufacturer Primary Reference Number Predicate Device K200321 Novaerus NV1050 / Novaerus US Inc  K203189 AEROCURE-MD / Aerobiotix, Inc.…
Novaerus Us, Inc.2020—
†K203189Aerocure-MDAerobiotix, Inc.2021—

Also cleared against K200321: 2 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K242102CerroZone MiniCerrozone, LLC20240

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 25 years and passes through 4 companies; a new generation was cleared every 10.0 years on median.
  • None of the 3 ancestors has a recall.
  • Of its descendants, K242102 (Cerrozone, LLC, 2024) has gone furthest, with 0 descendants of its own.
  • 2 other devices also cite its predicate K200321.

How does its category compare?

All FRF devices

FRF Cleaner, Air, Medical Recirculating: FDA decisions, review times, recalls and adverse event reports over 20 years. 2022, this device’s year, is highlighted.

FDA decisions per year · FRF

1in 2025

2007: 12008: 22013: 22020: 12022: 32023: 22024: 22025: 1
2007high 3 (2022) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FRF

163in 2022

2022: 163 days median
2007high 163 (2022)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FRF

1in 2012

2012: 1
2007high 1 (2012) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FRF

3in 2013

2007: 22008: 32011: 12012: 32013: 3
2007high 3 (2008) · low 0 (2009)2025

MAUDE reports naming product code FRF, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—02
20082—03
20090—00
20100—00
20110—01
20120—13
20132—03
20140—00
20150—00
20160—00
20170—00
20180—00
20190—00
20201—00
20210—00
2022316300
20232—00
20242—00
20251—00
20260—0—

What is it indicated for?

The CerroZone Mobile is intended as a room recirculating air cleaner. The system is used for filtering out and inactivating airborne particles (i.e., bacteria and viruses) from the air for medical purposes.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K220298: CerroZone Mobile.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K220298

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026