510(k) Report

510(k) · Cleared

Recalled · Class II · 2026

HD+12, HD+15

K220526510(k) TraditionalCleared May 15, 2023445-day reviewClass II21 CFR 870.2910Recalls 1

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Cardioline S.P.A · DRG Transmitters And Receivers, Physiological Signal, Radiofrequency

Cleared on May 15, 2023 as substantially equivalent to K150289 (Cardioline S.P.A, 2015) after a 445-day review. Its family tree reaches back 4 generations to 2000. It has been recalled once.

Decided
May 15, 2023
Review
445 days
Class
Class II
Product code
DRG
Recalls
1
Predicates
1

Its longest line of descent runs back 4 generations to K002074 (2000). 7 ancestors in all, the oldest K891104 (1989). No later device cites it as a predicate yet.

  1. Root · 4 generations backK002074 AB Cardiette Daedalus View Base and AB Cardiettte Daedalus View HesH&C Medical Devices Spa · 2000
  2. 3 generations backK051534 Cardioline AR 600, AR 1200, AR 2100Et Medical Devices Spa · 2005
  3. 2 generations backK082124 Carditte MicrotelEt Medical Devices Spa · 2009
  4. 1 generation backK150289 Cardioline HD+Cardioline S.P.A · 2015
  5. This deviceK220526 HD+12, HD+15Cardioline S.P.A · 2023
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K002074AB Cardiette Daedalus View Base and AB Cardiettte Daedalus View HesH&C Medical Devices Spa2000—
−3K051534Cardioline AR 600, AR 1200, AR 2100Et Medical Devices Spa2005—
−2K082124Carditte MicrotelEt Medical Devices Spa2009—
−1K150289Cardioline HD+Cardioline S.P.A2015—
0 (this device)K220526HD+12, HD+15Cardioline S.P.A2023—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198910
199310
199810
FIG. 1 — Lineage of K220526, 2000–2023Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DRG? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DRG device

  1. #1 K223711 ANNE Onescore 20.8 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K150289Cardioline HD+
Summary page 5
…ufacturer name Applicant Name Predicate Device 510(k) Number Cardioline S.p.A. Cardioline S.p.A. HD+ K150289 4. DEVICE DESCRIPTION HD+12 and HD+15 are the new revisions of Cardioline’s HD+ wireless acquisition module. The HD+ is…
Cardioline S.P.A2015—

Also cleared against K150289: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

Recalls of this device

DateClassRecallRoot causeReason
Jul 20, 2026Class IIZ-3013-2026Software designA communication anomoly may result in incorrect electrocardiogram waveforms of a patient and an inaccurate beats-per-minute calculation.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 23 years and passes through 3 companies; a new generation was cleared every 6.5 years on median.
  • 1 of the 7 ancestors has a recall of any class.
  • 2 other devices also cite its predicate K150289.

How does its category compare?

All DRG devices

DRG Transmitters And Receivers, Physiological Signal, Radiofrequency: FDA decisions, review times, recalls and adverse event reports over 20 years. 2023, this device’s year, is highlighted.

FDA decisions per year · DRG

3in 2025

2007: 62008: 52009: 132010: 102011: 92012: 122013: 132014: 102015: 22016: 22017: 72018: 62019: 52020: 62021: 22022: 62023: 42024: 32025: 32026 (partial year): 2
2007high 13 (2009) · low 2 (2015)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DRG

127in 2025

2007: 63 days median2008: 74 days median2009: 94 days median2010: 68 days median2011: 104 days median2012: 103 days median2013: 146 days median2014: 177 days median2017: 98 days median2018: 220 days median2019: 122 days median2020: 159 days median2022: 287 days median2023: 212 days median2024: 125 days median2025: 127 days median
2007high 287 (2022) · low 63 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DRG

3in 2007

2007: 32026 (partial year): 1
2007high 3 (2007) · low 0 (2008)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DRG

52in 2025

2007: 142008: 92009: 52010: 132011: 122012: 92013: 132014: 972015: 1312016: 1822017: 4842018: 1662019: 702020: 822021: 1072022: 432023: 192024: 262025: 52
2007high 484 (2017) · low 5 (2009)2025

MAUDE reports naming product code DRG, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007663314
200857409
2009139405
20101068013
20119104012
20121210309
201313146013
201410177097
20152—0131
20162—0182
20177980484
201862200166
20195122070
20206159082
20212—0107
20226287043
20234212019
20243125026
20253127052
20262—1—

What is it indicated for?

The function of the device is the acquisition and transmission of the ECG signal in order to support diagnosis of the patient’s conditions. HD+ is a wireless or USB (with appropriate option) ECG acquisition device, to be used primarily as common front-end for standard PC/tablet platforms (Windows/MAC OS/others), for resting ECG applications. The device implements wireless communication via Bluetooth wireless technology or wired with USB communication.…

Read the full statement (305 words)

The function of the device is the acquisition and transmission of the ECG signal in order to support diagnosis of the patient’s conditions.

HD+ is a wireless or USB (with appropriate option) ECG acquisition device, to be used primarily as common front-end for standard PC/tablet platforms (Windows/MAC OS/others), for resting ECG applications.

The device implements wireless communication via Bluetooth wireless technology or wired with USB communication. With both connection modes, HD+ sends the data to the receiver device without performing any analysis or filtering.

HD+ is not intended for monitoring or analysis of the cardiac function or to diagnose the patient’s health condition. Display, print and analysis applications on the receiver device are separate products. HD+ is not able to permanently store the acquired data, therefore it does not work unless a connection has been established with a receiver application. Furthermore, HD+ does not collect any of the patient’s sensitive data (patient’s name, age, previous health conditions etc.).

HD+ detects the QRS complexes and transmit the results to the receiving device. The QRS detection function is intended for patients aged 12 years or older.

*HD+ is indicated for the acquisition of ECG signals with the patient in resting conditions, for example for diagnostic ECG’s and rhythm strips

*HD+ is suitable for working at high altitudes, with restrictions.

*HD+ is intended for use on patients, with no limits of age or gender, except for the HR detector function which is intended for patients 12 years or older

*HD+ is intended for use in medical facilities (hospitals, clinics), at home or emergency settings (ambulances).

*HD+ is intended for use by a physician, nurse or other healthcare professional (e.g., ECG technician) who acts following orders by a physician or authorized nurse, including when operated in home environments

*HD+ is not intended for real-time monitoring of vital physiological parameters.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K220526: HD+12, HD+15.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K220526

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026