Powder-Free Nitrile Examination Glove Tested for Use with Chemotherapy Drugs and Fentanyl (White, Blue, Black, Orange and Green Color)

K220609510(k) TraditionalCleared May 27, 202286-day reviewClass I21 CFR 880.6250

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Encompass Industries Sdn. Bhd. · LZA Polymer Patient Examination Glove

Cleared on May 27, 2022 as substantially equivalent to K200181 (Comfort Rubber Gloves Industries Sdn. Bhd., 2020) after an 86-day review. Its family tree reaches back 2 generations to 2019.

Decided
May 27, 2022
Review
86 days
Class
Class I
Product code
LZA
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K183287 (2019). No later device cites it as a predicate yet.

  1. Root · 2 generations backK183287 Powder Free Nitrile Patient Examination Glove, Blue Colored…Kossan International Sdn Bhd · 2019
  2. 1 generation backK200181 Black Colored Powder Free Nitrile Examination Gloves Tested for Use…Comfort Rubber Gloves Industries Sdn. Bhd. · 2020
  3. This deviceK220609 Powder-Free Nitrile Examination Glove Tested for Use with…Encompass Industries Sdn. Bhd. · 2022
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K183287Powder Free Nitrile Patient Examination Glove, Blue Colored, Non-Sterile…Kossan International Sdn Bhd2019—
−1K200181Black Colored Powder Free Nitrile Examination Gloves Tested for Use with…Comfort Rubber Gloves Industries Sdn. Bhd.2020—
0 (this device)K220609Powder-Free Nitrile Examination Glove Tested for Use with Chemotherapy Drugs…Encompass Industries Sdn. Bhd.2022—
FIG. 1 — Lineage of K220609, 2019–2022Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LZA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LZA device

  1. #1 K192333 Blue Nitrile Examination Gloves Powder Freescore 71.0 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K200181Black Colored Powder Free Nitrile Examination Gloves Tested for Use with Chemotherapy…
Summary page 5
…lored, Powder Free Nitrile Examination Gloves, Non-sterile, Tested for Use with Chemotherapy Drugs and Fentanyl Citrate 510(k) number : K200181 Company : Comfort Rubber Glove Industries Sdn Bhd 4. Description of Device The proposed Powder-Free Nitrile Exami…
Comfort Rubber Gloves Industries Sdn. Bhd.2020—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 3 years and passes through 3 companies; a new generation was cleared every 2.1 years on median.
  • None of the 2 ancestors has a recall.

How does its category compare?

All LZA devices

LZA Polymer Patient Examination Glove: FDA decisions, review times, recalls and adverse event reports over 20 years. 2022, this device’s year, is highlighted.

FDA decisions per year · LZA

24in 2025

2007: 212008: 182009: 282010: 312011: 262012: 332013: 202014: 272015: 202016: 302017: 442018: 222019: 252020: 302021: 1392022: 1462023: 622024: 302025: 242026 (partial year): 15
2007high 146 (2022) · low 18 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LZA

110in 2025

2007: 95 days median2008: 97 days median2009: 112 days median2010: 97 days median2011: 122 days median2012: 110 days median2013: 130 days median2014: 197 days median2015: 112 days median2016: 171 days median2017: 124 days median2018: 178 days median2019: 212 days median2020: 101 days median2021: 111 days median2022: 111 days median2023: 92 days median2024: 89 days median2025: 110 days median2026 (partial year): 103 days median
2007high 212 (2019) · low 89 (2024)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LZA

3so far in 2026, the most since 2007

2015: 12016: 12026 (partial year): 3
2007high 3 (2026) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LZA

73in 2025

2007: 72008: 22009: 122010: 122011: 92012: 112013: 102014: 82015: 122016: 252017: 42018: 32019: 212020: 42021: 202022: 192023: 242024: 762025: 73
2007high 76 (2024) · low 2 (2008)2025

MAUDE reports naming product code LZA, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007219507
2008189702
200928112012
20103197012
20112612209
201233110011
201320130010
20142719708
201520112112
201630171125
20174412404
20182217803
201925212021
20203010104
2021139111020
2022146111019
20236292024
20243089076
202524110073
2026151033—

What is it indicated for?

A powder-free patient examination glove is a disposable device intended for medical purposes that is worn on the examiner's hand to prevent contamination between patient and examiner. In addition, the glove was tested for chemotherapy drugs permeation. The following chemotherapy drugs have been tested with the glove: Chemotherapy Drugs Carmustine Cisplatin Cyclophosphamide Dacarbazine Doxorubicin HCL Etoposide Fluorouracil Methotrexate Paclitaxel…

Read the full statement (192 words)

A powder-free patient examination glove is a disposable device intended for medical purposes that is worn on the examiner's hand to prevent contamination between patient and examiner. In addition, the glove was tested for

chemotherapy drugs permeation.

The following chemotherapy drugs have been tested with the glove:

Chemotherapy Drugs

Carmustine

Cisplatin

Cyclophosphamide

Dacarbazine

Doxorubicin HCL

Etoposide

Fluorouracil

Methotrexate

Paclitaxel

ThioTepa

Mitomycin C

Vincristine Sulfate

Fentanyl Citrate

Concentration

3.3 mg/ml

1.0 mg/ml

20.0 mg/ml

10.0 mg/ml

2.0 mg/ml

20.0 mg/ml

50.0 mg/ml

25.0 mg/ml

6.0 mg/ml

10.0 mg/ml

0.5 mg/ml

1.0 mg/ml

100 mcg/2mL

Breakthrough Detection Time in Minutes

White

11.2

>240

>240

>240

>240

>240

>240

>240

>240

25.2

>240

>240

>240

Blue

10.7

>240

>240

>240

>240

>240

>240

>240

>240

21.5

>240

>240

>240

*Please note that the following 2 drugs have extremely low permeation times:

1. Carmustine

2. Thiotepa

Warning: Do not use with Carmustine and ThioTepa.

Black

11.0

>240

>240

>240

>240

>240

>240

>240

>240

11.1

>240

>240

>240

Orange

67.3

>240

>240

>240

>240

>240

>240

>240

>240

47.8

>240

>240

>240

Green

67.1

>240

>240

>240

>240

>240

>240

>240

>240

169.1

>240

>240

>240

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K220609: Powder-Free Nitrile Examination Glove Tested for Use with Chemotherapy Drugs and Fentanyl (White, Blue, Black, Orange and Green Color).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K220609

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026