Acclarent, Inc. · PGW Ear, Nose, And Throat Stereotaxic Instrument
Cleared on Jul 20, 2022 as substantially equivalent to K130608 (Medtronic Navigation, Inc., 2013) after a 104-day review. Its family tree reaches back 2 generations to 2000.
- Decided
- Jul 20, 2022
- Review
- 104 days
- Class
- Class II
- Product code
- PGW
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 2 generations to K001284 (2000). No later device cites it as a predicate yet.
View FIG. 1 as a table
Line of descent and top descendants
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in PGW? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new PGW device
- #1 K261540 Cube 4D Navigation System, VirtuEye Proscore 12.9 · 6 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K130608 | QuadcutSummary page 4…oat Primary Product PGW Code: Secondary Product ERL Code: [807.92(a)(3)] Legally Marketed Devices Predicate Device: Medtronic Navigated Quadcut Blades (K130608) Reference Devices: Bien-Air OSSEODUO S120 Shaver Handpiece (Cleared OSSEODUO Shaver and Drill System… | 2013 |
| † | K083720 | Osseoduo, Shaver Handpiece S80 and S120, Micromotor 80K | 2009 |
| † | K201174 | TruDi Curette | 2020 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 22 years and passes through 3 companies; a new generation was cleared every 13.2 years on median.
- 2 of the 2 ancestors have a recall of any class.
- 2 other devices also cite its predicate K130608.
How does its category compare?
All PGW devicesPGW Ear, Nose, And Throat Stereotaxic Instrument: FDA decisions, review times, recalls and adverse event reports over 20 years. 2022, this device’s year, is highlighted.
FDA decisions per year · PGW
1in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · PGW
100in 2020
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · PGW
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · PGW
220in 2025
MAUDE reports naming product code PGW, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 0 | — | 0 | 0 |
| 2009 | 0 | — | 0 | 0 |
| 2010 | 0 | — | 0 | 0 |
| 2011 | 0 | — | 0 | 0 |
| 2012 | 0 | — | 0 | 0 |
| 2013 | 0 | — | 0 | 0 |
| 2014 | 4 | 116 | 0 | 7 |
| 2015 | 1 | — | 0 | 14 |
| 2016 | 9 | 115 | 0 | 33 |
| 2017 | 4 | 125 | 0 | 42 |
| 2018 | 2 | — | 0 | 96 |
| 2019 | 1 | — | 3 | 247 |
| 2020 | 8 | 100 | 0 | 161 |
| 2021 | 1 | — | 1 | 190 |
| 2022 | 2 | — | 0 | 166 |
| 2023 | 2 | — | 1 | 200 |
| 2024 | 0 | — | 0 | 274 |
| 2025 | 1 | — | 1 | 220 |
| 2026 | 3 | 65 | 0 | — |
What is it indicated for?
TruDi® Shaver Blades are intended for use with the Bien-Air S120 Shaver Handpiece and the TruDi® Navigation System to aid in the incision and removal of soft and hard tissue or bone in ENT, Maxillofacial surgery, Head and Neck and ENT skull base surgery. Their use is indicated for any medical condition in which the use of navigated surgery may be appropriate, and where reference to a rigid anatomical structure can be identified relative to a CT or MR…
Read the full statement (150 words)
TruDi® Shaver Blades are intended for use with the Bien-Air S120 Shaver Handpiece and the TruDi® Navigation System to aid in the incision and removal of soft and hard tissue or bone in ENT, Maxillofacial surgery, Head and Neck and ENT skull base surgery. Their use is indicated for any medical condition in which the use of navigated surgery may be appropriate, and where reference to a rigid anatomical structure can be identified relative to a CT or MR based model.
TruDi® Shaver Blades may be used in, but is not limited to, the following procedures:
* Endoscopic sinus surgery (such as ethmoidectomy, polypectomy, septoplasty)
* Drainage of mucoceles or abscesses that have extended from the paranasal sinuses and up to the dura mater
* Orbital decompression
* Any other of a number of tumors involving the lateral nasal wall, paranasal sinuses and orbit
* Access to the sphenoid sinus
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K221037 · printed Nov 6, 2026
Cite this page
510(k) Report. “K221037: TruDi Shaver Blade.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K221037
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026