510(k) Report

510(k) · Cleared

Cleared

AcQGuide® VUE Steerable Sheath

K221044510(k) TraditionalCleared May 5, 202227-day reviewClass II21 CFR 870.1280

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Acutus Medical, Inc. · DRA Catheter, Steerable

Cleared on May 5, 2022 as substantially equivalent to K211100 (Acutus Medical, Inc., 2021) after a 27-day review. Its family tree reaches back 6 generations to 2007.

Decided
May 5, 2022
Review
27 days
Class
Class II
Product code
DRA
Recalls
None
Predicates
1

Its longest line of descent runs back 6 generations to K070357 (2007). No later device cites it as a predicate yet.

  1. Root · 6 generations backK070357 Flexcath Steerable Sheath & DilatorCryocath Technologies, Inc. · 2007
  2. 5 generations backK081049 Flexcath Steerable Sheath & Dilator, Models 3FC10, 3FC12Cryocath Technologies, Inc. · 2008
  3. 4 generations backK102176 Flexcath Steerable Sheath (12 French), Flexcath Steerable Sheath (10…Medtronic Cryocath, LP · 2010 · Recalled
  4. 3 generations backK123591 Flexcath Advance Steerable Sheath (12 French)Medtronic Cryocath, LP · 2012
  5. 2 generations backK162925 AcQGuide Steerable SheathAcutus Medical, Inc. · 2017
  6. 1 generation backK211100 AcQGuide MAX Steerable SheathAcutus Medical, Inc. · 2021
  7. This deviceK221044 AcQGuide® VUE Steerable SheathAcutus Medical, Inc. · 2022
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K070357Flexcath Steerable Sheath & DilatorCryocath Technologies, Inc.2007—
−5K081049Flexcath Steerable Sheath & Dilator, Models 3FC10, 3FC12Cryocath Technologies, Inc.2008—
−4K102176Flexcath Steerable Sheath (12 French), Flexcath Steerable Sheath (10 French)…Medtronic Cryocath, LP20101
−3K123591Flexcath Advance Steerable Sheath (12 French)Medtronic Cryocath, LP2012—
−2K162925AcQGuide Steerable SheathAcutus Medical, Inc.2017—
−1K211100AcQGuide MAX Steerable SheathAcutus Medical, Inc.2021—
0 (this device)K221044AcQGuide® VUE Steerable SheathAcutus Medical, Inc.2022—
FIG. 1 — Lineage of K221044, 2007–2022Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DRA? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DRA device

  1. #1 K262165 FARADRIVE™ Steerable Sheath (M004PF21M402)score 13.2 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K211100AcQGuide MAX Steerable Sheath
Summary page 4
…ubstantial equivalence of the AcQGuide® VUE Steerable Sheath, Model 900201 is the Acutus Medical, Inc. AcQGuide® MAX Steerable Sheath, Model 900200, cleared under 510(k) K211100. This 510(k) is also citing the CARTO VIZIGO Bi-Directional Guiding Sheath cleared under K170997 as a reference device to support…
Acutus Medical, Inc.2021—
†K170997CARTO VIZIGO 8.5F Bi-Directional Guiding SheathBiosense Webster, Inc.20177

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 15 years and passes through 3 companies; a new generation was cleared every 2.3 years on median.
  • 1 of the 6 ancestors has a recall of any class.

How does its category compare?

All DRA devices

DRA Catheter, Steerable: FDA decisions, review times, recalls and adverse event reports over 20 years. 2022, this device’s year, is highlighted.

FDA decisions per year · DRA

1in 2025

2007: 12008: 12009: 22010: 32011: 12012: 42014: 12015: 12016: 42017: 22018: 12019: 22020: 12021: 12022: 22023: 32025: 12026 (partial year): 1
2007high 4 (2012) · low 0 (2013)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DRA

89in 2023

2010: 29 days median2012: 70 days median2016: 123 days median2023: 89 days median
2007high 123 (2016) · low 29 (2010)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DRA

4so far in 2026, the most since 2007

2008: 12011: 12026 (partial year): 4
2007high 4 (2026) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DRA

4,018in 2025

2007: 62008: 232009: 52010: 22011: 1552012: 892013: 1132014: 2122015: 3502016: 4812017: 6252018: 6332019: 7002020: 7032021: 7412022: 6522023: 7882024: 1,9622025: 4,018
2007high 4,018 (2025) · low 2 (2010)2025

MAUDE reports naming product code DRA, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—06
20081—123
20092—05
201032902
20111—1155
2012470089
20130—0113
20141—0212
20151—0350
201641230481
20172—0625
20181—0633
20192—0700
20201—0703
20211—0741
20222—0652
20233890788
20240—01,962
20251—04,018
20261—4—

What is it indicated for?

The AcQGuide® VUE Steerable Sheath with electrodes is intended for percutaneous catheter introduction into the

vasculature and into the chambers of the heart.

The AcQGuide® VUE deflection facilitates catheter positioning.

The electrodes help facilitate visualization of the sheath when used with a compatible localization system, such as the

AcQMap System.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K221044: AcQGuide® VUE Steerable Sheath.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K221044

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026