# K221516: ARTIS icono (Ceiling Configuration)

- Pathway: 510(k) (Traditional)
- Applicant: Siemens Medical Solutions USA, Inc.
- Decided: Jul 19, 2022 after 55 days
- Product code: OWB (Interventional Fluoroscopic X-Ray System)
- Device class: 2
- Regulation: 21 CFR 892.1650
- Recalls of this device: 3 (0 Class I)
- Data: FDA decisions to Oct 25, 2026; recalls to Oct 12, 2026

## Lineage
Longest line of descent: 12 generations back to K801623 (1980). 55 ancestors in all.
3 later devices descend from it; 1 cites it directly.
0 of 59 devices in its family (counting itself) have a Class I recall.

## Predicates on the family tree (from the FDA summary)
- K190768: ARTIS icono, Siemens Medical Solutions USA, Inc. (2019) Summary page 4.
- K181407: Artis zee/zeego & Artis Q/Q.zen, Siemens Medical Solution USA, Inc. (2018) Summary page 5.

## Most influential descendants
- K241572: ARTIS icono (VE40A) (floor); ARTIS icono (VE40A) (biplane); ARTIS icono (VE40A) (ceiling); ARTIS pheno (VE40A) (2024), 2 descendants of its own
- K254173: ARTIS icono floor; ARTIS icono biplane; ARTIS icono ceiling; ARTIS pheno (2026), 0 descendants of its own
- K253752: ARTIS genio floor; ARTIS icono.explore floor (2026), 0 descendants of its own

## Recalls of this device
- Jun 8, 2026 · Class II · Z-2648-2026: Potential issue with the Display ceiling suspension (DCS Fix XL) that holds the monitor in place. Over time some screws that keep the monitor attached to the suspension may gradually loosen.
- Jun 26, 2024 · Class II · Z-2241-2024: A potential issue with ARTIS icono systems equipped with a small detector and a corresponding collimator (model # 10843101) was identified. In very rare situations, the first x-ray release following p
- Oct 17, 2023 · Class II · Z-0523-2024: Potential hardware issue for ARTIS icono ceiling system: collision sensor may falsely signal non-existing collisions for up to half an hour when the system is switched off for a longer time (e.g., ove

## Indications for use
ARTIS is a family of dedicated angiography systems developed for single and biplane diagnostic imaging and interventional procedures including, but not limited to, pediatric and obese patients. Procedures that can be performed with the ARTIS family include cardiac angiography, neuro-angiography, general angiography, rotational angiography, multipurpose angiography and whole body radiographic/fluoroscopic procedures as well as procedures next to the table for i.e. patient extremities. This does not include projection radiography. Additional procedures that can be performed include angiography in the operating room, image guided surgery by X-ray, by image fusion, and by navigation systems. The examination table as an integrated part of the system can be used for X-ray imaging, surgery and interventions. ARTIS can also support the acquisition of position triggered imaging for spatial data synthesis. The ARTIS family include also the software option DynaCT with following indications for use: DynaCT is an X-ray imaging software option, which allows the reconstruction of two-dimensional images acquired with a standard angiographic C-arm device into a three-dimensional image format. DynaCT is intended for imaging both hard and soft tissues as well as other internal body structures for diagnosis, surgical planning, interventional procedures and treatment follow-up.