510(k) Report

510(k) · Cleared

Cleared

SafeSept® Transseptal Guidewire (SS-140)

K221707510(k) SpecialCleared Sep 14, 202293-day reviewClass II21 CFR 870.1390

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Pressure Products Medical Device Manufacturing, LLC · DRC Trocar

Cleared on Sep 14, 2022 as substantially equivalent to K170671 (Pressure Products Medical Device Manufacturing, LLC, 2017) after a 93-day review. Its family tree reaches back 2 generations to 2008.

Decided
Sep 14, 2022
Review
93 days
Class
Class II
Product code
DRC
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K081986 (2008). No later device cites it as a predicate yet.

  1. Root · 2 generations backK081986 Safesept Transseptal Trocar GuidewireOscor, Inc. · 2008
  2. 1 generation backK170671 SafeSept Transseptal GuidewirePressure Products Medical Device Manufacturing, LLC · 2017
  3. This deviceK221707 SafeSept® Transseptal Guidewire (SS-140)Pressure Products Medical Device Manufacturing, LLC · 2022
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K081986Safesept Transseptal Trocar GuidewireOscor, Inc.2008—
−1K170671SafeSept Transseptal GuidewirePressure Products Medical Device Manufacturing, LLC2017—
0 (this device)K221707SafeSept® Transseptal Guidewire (SS-140)Pressure Products Medical Device Manufacturing, LLC2022—
FIG. 1 — Lineage of K221707, 2008–2022Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DRC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DRC device

  1. #1 K241042 SafeSharp Transseptal Needle (CLICK071…score 9.2 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K170671SafeSept Transseptal Guidewire
Summary page 4
…Common/Usual Name: SafeSept Product Code: DRC Equivalent Legally Marketed Devices Pressure Products Medical Device Manufacturing LLC., SafeSept® Transseptal Guidewire, K170671 Description of the Device The SafeSept® .018” Transseptal Guidewire is made of nitinol, a flexible memory wire material, device…
Pressure Products Medical Device Manufacturing, LLC2017—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 14 years and passes through 2 companies; a new generation was cleared every 8.9 years on median.
  • None of the 2 ancestors has a recall.

How does its category compare?

All DRC devices

DRC Trocar: FDA decisions, review times, recalls and adverse event reports over 20 years. 2022, this device’s year, is highlighted.

FDA decisions per year · DRC

2in 2024

2007: 12008: 12011: 12012: 12013: 12014: 22017: 22018: 22021: 12022: 22024: 2
2007high 2 (2014) · low 0 (2009)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DRC

Too few DRC 510(k)s in any year since 2007 to give a median.

Recalls per year · DRC

1in 2021

2009: 12010: 12013: 12014: 12019: 1, 1 Class I2021: 1
2007high 1 (2009) · low 0 (2007)2026

Class I (1 since 2007) Class II/III not classified

Adverse event reports per year · DRC

69in 2025

2007: 1062008: 22009: 172010: 332011: 682012: 582013: 372014: 652015: 522016: 622017: 702018: 852019: 952020: 1082021: 782022: 612023: 1092024: 1052025: 69
2007high 109 (2023) · low 2 (2008)2025

MAUDE reports naming product code DRC, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—0106
20081—02
20090—117
20100—133
20111—068
20121—058
20131—137
20142—165
20150—052
20160—062
20172—070
20182—085
20190—1 (1)95
20200—0108
20211—178
20222—061
20230—0109
20242—0105
20250—069
20260—0—

What is it indicated for?

SafeSept® is indicated for use in procedures where access to the left atrium via the transseptal technique is desired. The SafeSept® Transseptal Guidewire is intended for single use only.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K221707: SafeSept® Transseptal Guidewire (SS-140).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K221707

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026