510(k) · Cleared
ClearedThe Oligio
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Wontech Co., Ltd. · GEI Electrosurgical, Cutting & Coagulation & Accessories
Cleared on Oct 13, 2022 as substantially equivalent to K170758 (Solta Medical, 2017) after a 99-day review. Its family tree reaches back 20 generations to 1995. 2 later devices descend from it.
- Decided
- Oct 13, 2022
- Review
- 99 days
- Class
- Class II
- Product code
- GEI
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 20 generations to K943450 (1995). 119 ancestors in all, the oldest K800617 (1980). 2 later devices descend from it, 1 citing it directly.
- Root · 20 generations backK943450 Arthrocare Arthroscopic Electrosurgery System Model 970Arthrocare Corp. · 1995
- 16 generations between
- 3 generations backK102698 Pelleve Glidesafe Non-Ablative Wrinkle Treatment System Model…Ellman Int'L, Inc. · 2011
- 2 generations backK132431 Thermage CPT SystemSolta Medical, Inc. · 2013 · Recalled
- 1 generation backK170758 Thermage FLX System and AccessoriesSolta Medical · 2017
- This deviceK221989 The OligioWontech Co., Ltd. · 2022
- Descendant · cites it directly · 1 of its ownK240313 Oligio XWontech Co., Ltd. · 2024
- Descendant · 2 generations on · 0 of its ownK243929 Oligio XWontech Co., Ltd. · 2025
Show all 20 generations
- Root · 20 generations backK943450 Arthrocare Arthroscopic Electrosurgery System Model 970Arthrocare Corp. · 1995
- 19 generations backK961069 Arthrocare Urologic Multi-Electrode Electrosurgery SystemArthrocare Corp. · 1996
- 18 generations backK962445 Arthrocare Dental Electrosurgery SystemArthrocare Corp. · 1996
- 17 generations backK964849 Arthrocare Dermatologic Electrosurgery SystemArthrocare Corp. · 1997
- 16 generations backK973478 Arthrocare Sinus Electrosurgery SystemArthrocare Corp. · 1998
- 15 generations backK981870 Visage Cosmetic Surgery SystemArthrocare Corp. · 1998
- 14 generations backK000944 Thermage Thermacool SystemThermage, Inc. · 2000
- 13 generations backK013034 Modification to: Thermacool IiaThermage, Inc. · 2001
- 12 generations backK013639 Thermage Thermacool TC SystemThermage, Inc. · 2002
- 11 generations backK021402 Thermage Thermacool TC SystemThermage, Inc. · 2002
- 10 generations backK030142 Thermacool TC SystemThermage, Inc. · 2003
- 9 generations backK031671 Polaris WRSyneron Medical, Ltd. · 2003
- 8 generations backK051214 Aluma Skin Renewal SystemLumenis, Inc. · 2005
- 7 generations backK070004 AccentAlma Lasers, Ltd. · 2007
- 6 generations backK072699 Alma Lasers Family of Accent Radiofrequency (RF) Systems, Models…Alma Lasers, Ltd. · 2007
- 5 generations backK101967 Non-Ablative Wrinkle Treatent Handpiece Modle Pelleve'Ellman Int'L, Inc. · 2010
- 4 generations backK102368 Non-Ablative Wrinkle Treatment HandpieceEllman Int'L, Inc. · 2010
- 3 generations backK102698 Pelleve Glidesafe Non-Ablative Wrinkle Treatment System Model…Ellman Int'L, Inc. · 2011
- 2 generations backK132431 Thermage CPT SystemSolta Medical, Inc. · 2013 · Recalled
- 1 generation backK170758 Thermage FLX System and AccessoriesSolta Medical · 2017
- This deviceK221989 The OligioWontech Co., Ltd. · 2022
Most influential descendants
Showing 2 of 2 · See allView FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −20 | K943450 | Arthrocare Arthroscopic Electrosurgery System Model 970 | Arthrocare Corp. | 1995 | — |
| −19 | K961069 | Arthrocare Urologic Multi-Electrode Electrosurgery System | Arthrocare Corp. | 1996 | — |
| −18 | K962445 | Arthrocare Dental Electrosurgery System | Arthrocare Corp. | 1996 | — |
| −17 | K964849 | Arthrocare Dermatologic Electrosurgery System | Arthrocare Corp. | 1997 | — |
| −16 | K973478 | Arthrocare Sinus Electrosurgery System | Arthrocare Corp. | 1998 | — |
| −15 | K981870 | Visage Cosmetic Surgery System | Arthrocare Corp. | 1998 | — |
| −14 | K000944 | Thermage Thermacool System | Thermage, Inc. | 2000 | — |
| −13 | K013034 | Modification to: Thermacool Iia | Thermage, Inc. | 2001 | — |
| −12 | K013639 | Thermage Thermacool TC System | Thermage, Inc. | 2002 | — |
| −11 | K021402 | Thermage Thermacool TC System | Thermage, Inc. | 2002 | — |
| −10 | K030142 | Thermacool TC System | Thermage, Inc. | 2003 | — |
| −9 | K031671 | Polaris WR | Syneron Medical, Ltd. | 2003 | — |
| −8 | K051214 | Aluma Skin Renewal System | Lumenis, Inc. | 2005 | — |
| −7 | K070004 | Accent | Alma Lasers, Ltd. | 2007 | — |
| −6 | K072699 | Alma Lasers Family of Accent Radiofrequency (RF) Systems, Models: Accent… | Alma Lasers, Ltd. | 2007 | — |
| −5 | K101967 | Non-Ablative Wrinkle Treatent Handpiece Modle Pelleve' | Ellman Int'L, Inc. | 2010 | — |
| −4 | K102368 | Non-Ablative Wrinkle Treatment Handpiece | Ellman Int'L, Inc. | 2010 | — |
| −3 | K102698 | Pelleve Glidesafe Non-Ablative Wrinkle Treatment System Model Pelleve Glidesafe | Ellman Int'L, Inc. | 2011 | — |
| −2 | K132431 | Thermage CPT System | Solta Medical, Inc. | 2013 | 1 |
| −1 | K170758 | Thermage FLX System and Accessories | Solta Medical | 2017 | — |
| 0 (this device) | K221989 | The Oligio | Wontech Co., Ltd. | 2022 | — |
| +1 | K240313 | Oligio X | Wontech Co., Ltd. | 2024 | — |
| +2 | K243929 | Oligio X | Wontech Co., Ltd. | 2025 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1980 | 1 | 0 |
| 1985 | 2 | 0 |
| 1990 | 1 | 0 |
| 1991 | 1 | 0 |
| 1992 | 3 | 0 |
| 1993 | 1 | 0 |
| 1994 | 3 | 0 |
| 1995 | 4 | 0 |
| 1996 | 11 | 0 |
| 1997 | 14 | 0 |
| 1998 | 6 | 0 |
| 1999 | 4 | 0 |
| 2000 | 10 | 0 |
| 2001 | 7 | 0 |
| 2002 | 9 | 0 |
| 2003 | 6 | 0 |
| 2004 | 3 | 0 |
| 2005 | 5 | 0 |
| 2006 | 1 | 0 |
| 2007 | 2 | 0 |
| 2008 | 2 | 0 |
| 2009 | 3 | 0 |
Descendants by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2024 | 1 | 0 |
| 2025 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in GEI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new GEI device
- #1 K231790 The InMode System with the Morpheus8 Applicatorsscore 32.7 · 21 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K170758 | Thermage FLX System and AccessoriesSummary page 5…e(s) [21 CFR 807.92(a)(3)] The identified predicate devices within this submission are shown as follow: Predicate device 510(k) Number: K170758 Applicant: Solta Medical Inc. Classification Name: Electrosurgical Cutting and Coagulatio… | 2017 |
What descends from it? (2)
1 later device cites it directly; ranked here by how many devices descend from each in turn.
| Number | Device | Decided | Descendants |
|---|---|---|---|
| K240313 | Oligio X | 2024 | 1 |
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 27 years and passes through 9 companies; a new generation was cleared every 10 months on median.
- 5 of the 119 ancestors have a recall of any class.
- Of its descendants, K240313 (Wontech Co., Ltd., 2024) has gone furthest, with 1 descendant of its own.
- 7 other devices also cite its predicate K170758.
How does its category compare?
All GEI devicesGEI Electrosurgical, Cutting & Coagulation & Accessories: FDA decisions, review times, recalls and adverse event reports over 20 years. 2022, this device’s year, is highlighted.
FDA decisions per year · GEI
52in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · GEI
113in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · GEI
4in 2025
Class I (14 since 2007) Class II/III not classified
Adverse event reports per year · GEI
7,592in 2025
MAUDE reports naming product code GEI, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 50 | 51 | 21 | 2,795 |
| 2008 | 61 | 71 | 19 | 2,556 |
| 2009 | 42 | 130 | 27 | 3,591 |
| 2010 | 46 | 109 | 51 | 3,377 |
| 2011 | 35 | 135 | 32 | 4,463 |
| 2012 | 39 | 133 | 30 | 5,216 |
| 2013 | 48 | 136 | 13 | 4,897 |
| 2014 | 49 | 103 | 3 | 4,908 |
| 2015 | 47 | 123 | 4 | 4,936 |
| 2016 | 64 | 108 | 3 | 5,616 |
| 2017 | 52 | 72 | 2 | 6,073 |
| 2018 | 47 | 93 | 6 | 6,545 |
| 2019 | 48 | 93 | 5 | 7,067 |
| 2020 | 59 | 105 | 1 | 6,490 |
| 2021 | 46 | 146 | 6 | 6,354 |
| 2022 | 55 | 150 | 49 | 6,103 |
| 2023 | 65 | 104 | 27 (4) | 7,176 |
| 2024 | 59 | 125 | 22 (10) | 7,897 |
| 2025 | 52 | 113 | 4 | 7,592 |
| 2026 | 43 | 183 | 8 | — |
What is it indicated for?
‘The Oligio’ is intended for use in dermatologic and general surgical procedures for electrocoagulation and hemostasis of soft tissue.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K221989 · printed Nov 4, 2026
Cite this page
510(k) Report. “K221989: The Oligio.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K221989
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026