510(k) Report

510(k) · Cleared

Cleared

Lianfa Safety Lancet (Five Models: NPA, PA, PA2, TPA, and APA)

K222376510(k) TraditionalCleared Oct 3, 202259-day reviewClass II21 CFR 878.4850

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Shandong Lianfa Medical Plastic Products Co., Ltd. · FMK Single Use Only Blood Lancet With An Integral Sharps Injury Prevention Feature

Cleared on Oct 3, 2022 as substantially equivalent to K220370 (Tianjin Huahong Technology Co., Ltd., 2022) after a 59-day review. Its family tree reaches back 4 generations to 1982.

Decided
Oct 3, 2022
Review
59 days
Class
Class II
Product code
FMK
Recalls
None
Predicates
1

Its longest line of descent runs back 4 generations to K822209 (1982). 6 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 4 generations backK822209 AutolancetBd Becton Dickinson Vacutainer Systems Preanalytic · 1982
  2. 3 generations backK101145 Surgilance Safety Lancets, Models SLN100, SLN200, SLN240, SLN300…Medipurpose Pte., Ltd. · 2010
  3. 2 generations backK192666 Promisemed Blood Lancet, VeriFine Safety Lancet, VeriFine…Promisemed Hangzhou Meditech Co., Ltd. · 2019
  4. 1 generation backK220370 Safety Lancet (XIII, XVII, XXI, XXII, XXIII, XXIV, XXV, XXVI)Tianjin Huahong Technology Co., Ltd. · 2022
  5. This deviceK222376 Lianfa Safety Lancet (Five Models: NPA, PA, PA2, TPA, and APA)Shandong Lianfa Medical Plastic Products Co., Ltd. · 2022
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K822209AutolancetBd Becton Dickinson Vacutainer Systems Preanalytic1982—
−3K101145Surgilance Safety Lancets, Models SLN100, SLN200, SLN240, SLN300, SLB200, SLB250Medipurpose Pte., Ltd.2010—
−2K192666Promisemed Blood Lancet, VeriFine Safety Lancet, VeriFine Mini-Safety LancetPromisemed Hangzhou Meditech Co., Ltd.2019—
−1K220370Safety Lancet (XIII, XVII, XXI, XXII, XXIII, XXIV, XXV, XXVI)Tianjin Huahong Technology Co., Ltd.2022—
0 (this device)K222376Lianfa Safety Lancet (Five Models: NPA, PA, PA2, TPA, and APA)Shandong Lianfa Medical Plastic Products Co., Ltd.2022—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199310
201210
FIG. 1 — Lineage of K222376, 1982–2022Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in FMK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new FMK device

  1. #1 K220370 Safety Lancet (XIII, XVII, XXI, XXII, XXIII…score 25.0 · 3 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K220370Safety Lancet (XIII, XVII, XXI, XXII, XXIII, XXIV, XXV, XXVI)
Summary page 4
…General & Plastic Surgery Regulation Number: 21 CFR 878.4850 Product Code: FMK III Predicate Device Information: (1) K220370, “Safety Lancet (8 Models: XIII, XVII, XXI, XXII, XXIII, XXIV, XXV, XXVI)”, manufactured by “Tianjin Huahong Technology Co., Ltd.…
Tianjin Huahong Technology Co., Ltd.2022—

Also cleared against K220370: 6 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 40 years and passes through 5 companies; a new generation was cleared every 9.1 years on median.
  • None of the 6 ancestors has a recall.
  • 6 other devices also cite its predicate K220370.

How does its category compare?

All FMK devices

FMK Single Use Only Blood Lancet With An Integral Sharps Injury Prevention Feature: FDA decisions, review times, recalls and adverse event reports over 20 years. 2022, this device’s year, is highlighted.

FDA decisions per year · FMK

4in 2025

2010: 22012: 22013: 12016: 12017: 12019: 22021: 12022: 252023: 102024: 102025: 42026 (partial year): 5
2007high 25 (2022) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · FMK

59in 2025

2022: 87 days median2023: 95 days median2024: 57 days median2025: 59 days median2026 (partial year): 68 days median
2007high 95 (2023) · low 57 (2024)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · FMK

1in 2009

2007: 42008: 22009: 1
2007high 4 (2007) · low 0 (2010)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · FMK

47in 2025

2007: 1,2062008: 1,1002009: 8822010: 9102011: 1,4932012: 1,5732013: 1,3012014: 8902015: 7812016: 5392017: 5312018: 5342019: 3992020: 3132021: 2452022: 2542023: 2822024: 2432025: 47
2007high 1,573 (2012) · low 47 (2025)2025

MAUDE reports naming product code FMK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—41,206
20080—21,100
20090—1882
20102—0910
20110—01,493
20122—01,573
20131—01,301
20140—0890
20150—0781
20161—0539
20171—0531
20180—0534
20192—0399
20200—0313
20211—0245
202225870254
202310950282
202410570243
2025459047
20265680—

What is it indicated for?

Lianfa Safety Lancet (Five Models: NPA, PA, PA2, TPA, and APA) is a single use device indicated for capillary blood sampling.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K222376: Lianfa Safety Lancet (Five Models: NPA, PA, PA2, TPA, and APA).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K222376

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026