TruPlan Computed Tomography (CT) Imaging Software

K222593510(k) TraditionalCleared Jan 18, 2023145-day reviewClass II21 CFR 892.2050

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Circle Cardiovascular Imaging, Inc. · LLZ System, Image Processing, Radiological

Cleared on Jan 18, 2023 as substantially equivalent to K202212 (Circle Cardiovascular Imaging, Inc., 2021) and 1 other predicate after a 145-day review. Its family tree reaches back 8 generations to 1996. 2 later devices descend from it.

Decided
Jan 18, 2023
Review
145 days
Class
Class II
Product code
LLZ
Recalls
None
Predicates
2

Its longest line of descent runs back 8 generations to K954678 (1996). 20 ancestors in all, the oldest K954668 (1995). 2 later devices descend from it, 2 citing it directly.

Other ancestors, by year clearedDescendants, by year cleared 2015: 1 other ancestor2006: 2 other ancestors2004: 2 other ancestors2002: 1 other ancestor2000: 1 other ancestor1995: 1 other ancestor2001: 1 other ancestor1997: 1 other ancestor1996: 2 other ancestors2025: 1 descendant cleared2026: 1 descendant clearedK954678 · Pro Vision · Algotec Systems, Ltd. · 1996K980648 · Pro Vision · Algotec Systems, Ltd. · 1998K992654 · Plug 'N View 3D, Version 1.0 · Voxar Limited · 1999K043097 · 3VISEON · 3Mensio Medical Imaging BV · 2004K072653 · 3VISEON/Surgery · 3Mensio Medical Imaging BV · 2008K120367 · 3MENSIO Workstation · Pie Medical Imaging BV · 2012K153736 · 3mensio Workstation · Pie Medical Imaging BV · 2016 · recalledK202212 · TruPlan · Circle Cardiovascular Imaging, Inc. · 20211995200020052010201520202025
Other ancestors, by generationDescendants, by generation 2 generations back: 1 other ancestor3 generations back: 1 other ancestor4 generations back: 3 other ancestors5 generations back: 3 other ancestors6 generations back: 2 other ancestors7 generations back: 2 other ancestors 1 generation forward: 2 descendants K202212 · TruPlan · Circle Cardiovascular Imaging, Inc. · 2021K153736 · 3mensio Workstation · Pie Medical Imaging BV · 2016 · recalledK120367 · 3MENSIO Workstation · Pie Medical Imaging BV · 2012K072653 · 3VISEON/Surgery · 3Mensio Medical Imaging BV · 2008K043097 · 3VISEON · 3Mensio Medical Imaging BV · 2004K992654 · Plug 'N View 3D, Version 1.0 · Voxar Limited · 1999K980648 · Pro Vision · Algotec Systems, Ltd. · 1998K954678 · Pro Vision · Algotec Systems, Ltd. · 1996−50
  1. Root · 8 generations backK954678 Pro VisionAlgotec Systems, Ltd. · 1996
  2. 7 generations backK980648 Pro VisionAlgotec Systems, Ltd. · 1998
  3. 6 generations backK992654 Plug 'N View 3D, Version 1.0Voxar Limited · 1999
  4. 5 generations backK043097 3VISEON3Mensio Medical Imaging BV · 2004
  5. 4 generations backK072653 3VISEON/Surgery3Mensio Medical Imaging BV · 2008
  6. 3 generations backK120367 3MENSIO WorkstationPie Medical Imaging BV · 2012
  7. 2 generations backK153736 3mensio WorkstationPie Medical Imaging BV · 2016 · Recalled
  8. 1 generation backK202212 TruPlanCircle Cardiovascular Imaging, Inc. · 2021
  9. This deviceK222593 TruPlan Computed Tomography (CT) Imaging SoftwareCircle Cardiovascular Imaging, Inc. · 2023
  10. Descendant · cites it directly · 0 of its ownK260300 WatchMate SoftwareAnumana, Inc. · 2026
  11. Descendant · cites it directly · 0 of its ownK242166 TribusConnectTribusmed Beheer BV · 2025

Most influential descendants

Showing 2 of 2 · See all
  • K260300WatchMate SoftwareAnumana, Inc. · 2026 · cites it directly0descendants
  • K242166TribusConnectTribusmed Beheer BV · 2025 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−8K954678Pro VisionAlgotec Systems, Ltd.1996—
−7K980648Pro VisionAlgotec Systems, Ltd.1998—
−6K992654Plug 'N View 3D, Version 1.0Voxar Limited1999—
−5K0430973VISEON3Mensio Medical Imaging BV2004—
−4K0726533VISEON/Surgery3Mensio Medical Imaging BV2008—
−3K1203673MENSIO WorkstationPie Medical Imaging BV2012—
−2K1537363mensio WorkstationPie Medical Imaging BV20161
−1K202212TruPlanCircle Cardiovascular Imaging, Inc.2021—
0 (this device)K222593TruPlan Computed Tomography (CT) Imaging SoftwareCircle Cardiovascular Imaging, Inc.2023—
+1K260300WatchMate SoftwareAnumana, Inc.2026—
+1K242166TribusConnectTribusmed Beheer BV2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199510
199620
199710
200010
200110
200210
200420
200620
201510

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202510
202610
FIG. 1 — Lineage of K222593, 1996–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LLZ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LLZ device

  1. #1 K230955 syngo Application Softwarescore 21.5 · 11 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K202212TruPlan
Summary page 4
…Number: 21 CFR 892.2050 III. PREDICATE DEVICES The primary predicate is the previously cleared version of TruPlan, manufactured by Circle CVI and cleared under K202212. 3mensio Workstation, manufactured by Pie Medical Imaging and cleared under K153736, is used as a secondary predicate. The predi…
Circle Cardiovascular Imaging, Inc.2021—
*K1537363mensio Workstation
Summary page 4
…e previously cleared version of TruPlan, manufactured by Circle CVI and cleared under K202212. 3mensio Workstation, manufactured by Pie Medical Imaging and cleared under K153736, is used as a secondary predicate. The predicate devices have not been subject to a design-related recall. Circle Cardiovasc…
Pie Medical Imaging BV20161

What descends from it? (2)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K260300WatchMate SoftwareAnumana, Inc.20260
K242166TribusConnectTribusmed Beheer BV20250

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 27 years and passes through 5 companies; a new generation was cleared every 4.1 years on median.
  • 5 of the 20 ancestors have a recall of any class.
  • Of its descendants, K260300 (Anumana, Inc., 2026) has gone furthest, with 0 descendants of its own.

How does its category compare?

All LLZ devices

LLZ System, Image Processing, Radiological: FDA decisions, review times, recalls and adverse event reports over 20 years. 2023, this device’s year, is highlighted.

FDA decisions per year · LLZ

58in 2025

2007: 762008: 942009: 702010: 512011: 1062012: 822013: 952014: 782015: 642016: 822017: 782018: 1042019: 742020: 812021: 832022: 652023: 872024: 622025: 582026 (partial year): 45
2007high 106 (2011) · low 51 (2010)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LLZ

173in 2025

2007: 36 days median2008: 52 days median2009: 62 days median2010: 98 days median2011: 79 days median2012: 87 days median2013: 84 days median2014: 89 days median2015: 90 days median2016: 90 days median2017: 107 days median2018: 105 days median2019: 107 days median2020: 115 days median2021: 116 days median2022: 137 days median2023: 157 days median2024: 131 days median2025: 173 days median2026 (partial year): 110 days median
2007high 173 (2025) · low 36 (2007)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LLZ

11in 2025

2007: 202008: 322009: 212010: 172011: 302012: 122013: 642014: 62015: 162016: 122017: 52018: 72019: 22020: 62021: 32022: 42023: 82024: 62025: 112026 (partial year): 14
2007high 64 (2013) · low 2 (2019)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · LLZ

116in 2025

2007: 1522008: 1542009: 1452010: 1452011: 4542012: 2662013: 1,1302014: 15,6312015: 2112016: 2902017: 1042018: 722019: 882020: 822021: 702022: 282023: 262024: 422025: 116
2007high 15,631 (2014) · low 26 (2023)2025

MAUDE reports naming product code LLZ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007763620152
2008945232154
2009706221145
2010519817145
20111067930454
2012828712266
20139584641,130
20147889615,631
2015649016211
2016829012290
2017781075104
2018104105772
201974107288
202081115682
202183116370
202265137428
202387157826
202462131642
20255817311116
20264511014—

What is it indicated for?

TruPlan enables visualization and measurement of structures of the heart and vessels for:

• Pre-procedural planning and sizing for the left atrial appendage closure (LAAC) procedure

• Post-procedural evaluation for the LAAC procedure

To facilitate the above, TruPlan provides general functionality such as:

• Segmentation of cardiovascular structures

• Visualization and image reconstruction techniques: 2D review, Volume Rendering, MPR

• Simulation of TEE views, ICE views, and fluoroscopic rendering

• Measurement and annotation tools

• Reporting tools

TruPlan’s intended patient population is comprised of adult patients.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K222593: TruPlan Computed Tomography (CT) Imaging Software.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K222593

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026