510(k) Report

510(k) · Cleared

Cleared

SmartGUIDE deflectable hydrophilic guidewire

K222690510(k) TraditionalCleared Apr 24, 2023230-day reviewClass II21 CFR 870.1330

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Artiria Medical SA · MOF Guide, Wire, Catheter, Neurovasculature

Cleared on Apr 24, 2023 as substantially equivalent to K190843 (Stryker, 2019) and 1 other predicate after a 230-day review. Its family tree reaches back 5 generations to 2000.

Decided
Apr 24, 2023
Review
230 days
Class
Class II
Product code
MOF
Recalls
None
Predicates
2

Its longest line of descent runs back 5 generations to K002212 (2000). 7 ancestors in all, the oldest K913074 (1991). No later device cites it as a predicate yet.

  1. Root · 5 generations backK002212 Mirage Hydrophilic Guidewire, Model 103-0608Micro Therapeutics, Inc. · 2000
  2. 4 generations backK032146 PVS 1300 Synchro 0.014 & PVS 1600 Synchro 0.010 Guide WiresPrecision Vascular Systems, Inc. · 2003 · Recalled
  3. 3 generations backK050964 PV 1900 Synchro 0.016 GuidewireBoston Scientific - Precision Vascular · 2005 · Recalled
  4. 2 generations backK053268 PVS 2000 SYNCHRO2 GuidewireBoston Scientific - Precision Vascular · 2006 · Recalled
  5. 1 generation backK190843 Synchro2 Support GuidewireStryker · 2019 · Recalled
  6. This deviceK222690 SmartGUIDE deflectable hydrophilic guidewireArtiria Medical SA · 2023
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K002212Mirage Hydrophilic Guidewire, Model 103-0608Micro Therapeutics, Inc.2000—
−4K032146PVS 1300 Synchro 0.014 & PVS 1600 Synchro 0.010 Guide WiresPrecision Vascular Systems, Inc.20031
−3K050964PV 1900 Synchro 0.016 GuidewireBoston Scientific - Precision Vascular20056
−2K053268PVS 2000 SYNCHRO2 GuidewireBoston Scientific - Precision Vascular200613
−1K190843Synchro2 Support GuidewireStryker20198
0 (this device)K222690SmartGUIDE deflectable hydrophilic guidewireArtiria Medical SA2023—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199110
199710
FIG. 1 — Lineage of K222690, 2000–2023Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in MOF? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new MOF device

  1. #1 K253168 0.014” Willow Guidewirescore 17.9 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K190843Synchro2 Support Guidewire
Summary page 4
…21 CFR 870.1330 Product Code: MOF, DQX Device Class: II Predicate Device(s): Primary predicate: Synchro2 Support Guidewire (K190843, product code MOF, DQX) Predicate: PV 2000 Synchro2 Guidewire (K053268, product code DQX) Reference: Columbus…
Stryker20198
*K053268PVS 2000 SYNCHRO2 Guidewire
Summary page 4
…II Predicate Device(s): Primary predicate: Synchro2 Support Guidewire (K190843, product code MOF, DQX) Predicate: PV 2000 Synchro2 Guidewire (K053268, product code DQX) Reference: Columbus Guidewire (K200374, product code MOF, DQX) Indications for Use Statement The I…
Boston Scientific - Precision Vascular200613
†K200374Columbus GuidewireRapid-Medical, Ltd.2020—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 23 years and passes through 5 companies; a new generation was cleared every 3.0 years on median.
  • 4 of the 7 ancestors have a recall of any class.

How does its category compare?

All MOF devices

MOF Guide, Wire, Catheter, Neurovasculature: FDA decisions, review times, recalls and adverse event reports over 20 years. 2023, this device’s year, is highlighted.

FDA decisions per year · MOF

11so far in 2026, the most since 2007

2011: 22014: 22015: 32016: 42017: 12018: 22019: 42020: 42022: 12023: 42024: 22025: 52026 (partial year): 11
2007high 11 (2026) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · MOF

172in 2025

2015: 133 days median2016: 61 days median2019: 58 days median2020: 36 days median2023: 199 days median2025: 172 days median2026 (partial year): 192 days median
2007high 199 (2023) · low 36 (2020)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · MOF

No recall names MOF since 2007.

Adverse event reports per year · MOF

135in 2025

2008: 12012: 22013: 22015: 52016: 32017: 152018: 112019: 122020: 182021: 392022: 922023: 912024: 952025: 135
2007high 135 (2025) · low 0 (2007)2025

MAUDE reports naming product code MOF, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—01
20090—00
20100—00
20112—00
20120—02
20130—02
20142—00
2015313305
201646103
20171—015
20182—011
2019458012
2020436018
20210—039
20221—092
20234199091
20242—095
202551720135
2026111920—

What is it indicated for?

SmartGUIDE guidewire is intended for general intravascular use, including neurovascular and peripheral vasculatures. It can be used to selectively introduce and position catheters and other interventional devices within the peripheral and neurovasculature. SmartGUIDE is intended to be used only by physicians trained in percutaneous, intravascular techniques and procedures.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K222690: SmartGUIDE deflectable hydrophilic guidewire.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K222690

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026