Varian Medical Systems, Inc. · JAQ System, Applicator, Radionuclide, Remote-Controlled

Cleared on Mar 13, 2023 as substantially equivalent to K150839 (Varian Medical Systems, Inc., 2015) after a 180-day review. Its family tree reaches back 5 generations to 1986. 1 later device descends from it.

Decided
Mar 13, 2023
Review
180 days
Class
Class II
Product code
JAQ
Recalls
None
Predicates
1

Its longest line of descent runs back 5 generations to K864210 (1986). 6 ancestors in all. 1 later device descends from it, 1 citing it directly.

  1. Root · 5 generations backK864210 Microselectron-HDR (High Dose Rate)Nucletron-Oldelft Corp. · 1986
  2. 4 generations backK953946 Microselectron-HDR Version 2Nucletron-Oldelft Corp. · 1996
  3. 3 generations backK011657 HDR Tandem/Ring Applicator with Rectal RetractorMick Radio-Nuclear Instruments, Inc. · 2001 · Recalled
  4. 2 generations backK030110 CT HDR Tandem/Ring Applicator with Rectal RetractorMick Radio-Nuclear Instruments, Inc. · 2003 · Recalled
  5. 1 generation backK150839 3D Interstitial Ring Applicator Set 60, 3D Interstitial Ring…Varian Medical Systems, Inc. · 2015
  6. This deviceK222775 Aarhus Applicator SetVarian Medical Systems, Inc. · 2023
  7. Descendant · cites it directly · 0 of its ownK252884 Guided Aarhus Applicator SetVarian Medical Systems · 2025

Most influential descendants

Showing 1 of 1 · See all
  • K252884Guided Aarhus Applicator SetVarian Medical Systems · 2025 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K864210Microselectron-HDR (High Dose Rate)Nucletron-Oldelft Corp.1986—
−4K953946Microselectron-HDR Version 2Nucletron-Oldelft Corp.1996—
−3K011657HDR Tandem/Ring Applicator with Rectal RetractorMick Radio-Nuclear Instruments, Inc.20012
−2K030110CT HDR Tandem/Ring Applicator with Rectal RetractorMick Radio-Nuclear Instruments, Inc.20031
−1K1508393D Interstitial Ring Applicator Set 60, 3D Interstitial Ring Applicator Set…Varian Medical Systems, Inc.2015—
0 (this device)K222775Aarhus Applicator SetVarian Medical Systems, Inc.2023—
+1K252884Guided Aarhus Applicator SetVarian Medical Systems2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199310

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202510
FIG. 1 — Lineage of K222775, 1986–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JAQ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new JAQ device

  1. #1 K241853 Titanium Fletcher-Style Applicator Set Defined…score 14.9 · 3 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K1508393D Interstitial Ring Applicator Set 60, 3D Interstitial Ring Applicator Set 90, Ring…
Summary page 4
…Ring Applicator Set 45, Set 60, Set 90 Common/Usual Name: (K150839) Afterloader System Source Guide Tubes Brachytherapy Accessory Re…
Varian Medical Systems, Inc.2015—

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K252884Guided Aarhus Applicator SetVarian Medical Systems20250

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 37 years and passes through 3 companies; a new generation was cleared every 7.7 years on median.
  • 2 of the 6 ancestors have a recall of any class.
  • Of its descendants, K252884 (Varian Medical Systems, 2025) has gone furthest, with 0 descendants of its own.

How does its category compare?

All JAQ devices

JAQ System, Applicator, Radionuclide, Remote-Controlled: FDA decisions, review times, recalls and adverse event reports over 20 years. 2023, this device’s year, is highlighted.

FDA decisions per year · JAQ

6in 2025

2007: 112008: 102009: 102010: 22011: 22012: 72013: 62014: 72015: 112016: 62017: 72018: 72019: 22020: 42022: 12023: 22024: 102025: 62026 (partial year): 2
2007high 11 (2007) · low 0 (2021)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JAQ

91in 2025

2007: 48 days median2008: 34 days median2009: 27 days median2012: 89 days median2013: 100 days median2014: 116 days median2015: 183 days median2016: 154 days median2017: 229 days median2018: 252 days median2020: 62 days median2024: 126 days median2025: 91 days median
2007high 252 (2018) · low 27 (2009)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · JAQ

1in 2019

2008: 52009: 12010: 22011: 132012: 52013: 12019: 12026 (partial year): 3
2007high 13 (2011) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JAQ

3in 2025

2007: 132008: 322009: 352010: 362011: 422012: 342013: 432014: 182015: 72016: 32017: 52018: 22019: 82020: 82021: 52022: 52023: 32024: 12025: 3
2007high 43 (2013) · low 1 (2024)2025

MAUDE reports naming product code JAQ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071148013
20081034532
20091027135
20102—236
20112—1342
2012789534
20136100143
20147116018
20151118307
2016615403
2017722905
2018725202
20192—18
202046208
20210—05
20221—05
20232—03
20241012601
202569103
20262—3—

What is it indicated for?

The Aarhus Applicator Set is indicated for cancer treatment of the vagina, cervix, and uterus using HDR or PDR brachytherapy within a hospital CT or MRI environment.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K222775: Aarhus Applicator Set.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K222775

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026