510(k) Report

510(k) · Cleared

Cleared

3M V.A.C. Peel and Place Dressing Kit, Small (EZ10SML), 3M V.A.C. Peel and Place Dressing Kit, Medium (EZ10MED), 3M V.A.C. Peel and Place Dressing Kit, Large (EZ10LRG)

K222859510(k) TraditionalCleared Mar 23, 2023182-day reviewClass II21 CFR 878.4780

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

3M · OMP Negative Pressure Wound Therapy Powered Suction Pump

Cleared on Mar 23, 2023 as substantially equivalent to K212320 (3M Healthcare Business Group, 2021) after a 182-day review. Its family tree reaches back 5 generations to 2010.

Decided
Mar 23, 2023
Review
182 days
Class
Class II
Product code
OMP
Recalls
None
Predicates
1

Its longest line of descent runs back 5 generations to K100821 (2010). No later device cites it as a predicate yet.

  1. Root · 5 generations backK100821 Prevena Incision Management SystemKci USA, Inc. · 2010 · Recalled
  2. 4 generations backK120033 Activac Therapy Unit and Infovac Therapy Unit, Vac Ats Therapy Unit…Kci USA, Inc. · 2012
  3. 3 generations backK133276 V.a.C. Granufoam Dressing, Granufoam Thin Dressing, Granufoam Round…Kci USA, Inc. · 2013
  4. 2 generations backK181505 V.A.C. DERMATAC DrapeKci USA, Inc. · 2019
  5. 1 generation backK212320 Dermatac™ Drape and V.A.C. Granufoam Dressings Featuring…3M Healthcare Business Group · 2021
  6. This deviceK222859 3M V.A.C. Peel and Place Dressing Kit, Small (EZ10SML), 3M V.A.C.…3M · 2023
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K100821Prevena Incision Management SystemKci USA, Inc.20108
−4K120033Activac Therapy Unit and Infovac Therapy Unit, Vac Ats Therapy Unit and Vac…Kci USA, Inc.2012—
−3K133276V.a.C. Granufoam Dressing, Granufoam Thin Dressing, Granufoam Round Dressing…Kci USA, Inc.2013—
−2K181505V.A.C. DERMATAC DrapeKci USA, Inc.2019—
−1K212320Dermatac™ Drape and V.A.C. Granufoam Dressings Featuring SensaT.R.A.C.…3M Healthcare Business Group2021—
0 (this device)K2228593M V.A.C. Peel and Place Dressing Kit, Small (EZ10SML), 3M V.A.C. Peel and…3M2023—
FIG. 1 — Lineage of K222859, 2010–2023Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in OMP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new OMP device

  1. #1 K260646 Renasys Edge (66803126)score 15.3 · 14 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K212320Dermatac™ Drape and V.A.C. Granufoam Dressings Featuring SensaT.R.A.C. Technology-Small…
Summary page 4
…5038 Date Prepared: March 15, 2023 Name of Subject Device: 3M™ V.A.C. ® Peel and Place Dressing Predicate Device: V.A.C. DERMATAC™ Drape and V.A.C. Granufoam Dressing (K212320 Reference Device: Pico Single Use NPWT System (K180698) Common or Usual Name: Dressing component of Negative Pressure Wound Thera…
3M Healthcare Business Group2021—
†K180698PICO 7 Single Use Negative Pressure Wound Therapy SystemSmith & Nephew Medical Limited2018—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 13 years and passes through 3 companies; a new generation was cleared every 2.0 years on median.
  • 1 of the 5 ancestors has a recall of any class.

How does its category compare?

All OMP devices

OMP Negative Pressure Wound Therapy Powered Suction Pump: FDA decisions, review times, recalls and adverse event reports over 20 years. 2023, this device’s year, is highlighted.

FDA decisions per year · OMP

5in 2025

2007: 62008: 82009: 82010: 62011: 62012: 112013: 112014: 102015: 202016: 192017: 112018: 132019: 152020: 62021: 92022: 102023: 82024: 92025: 52026 (partial year): 9
2007high 20 (2015) · low 5 (2025)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · OMP

127in 2025

2007: 113 days median2008: 98 days median2009: 87 days median2010: 97 days median2011: 123 days median2012: 292 days median2013: 84 days median2014: 179 days median2015: 189 days median2016: 146 days median2017: 137 days median2018: 214 days median2019: 249 days median2020: 179 days median2021: 238 days median2022: 229 days median2023: 291 days median2024: 181 days median2025: 127 days median2026 (partial year): 141 days median
2007high 292 (2012) · low 84 (2013)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · OMP

2in 2024

2009: 72010: 32012: 12013: 22014: 42015: 12016: 22019: 12024: 2
2007high 7 (2009) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · OMP

140in 2025

2007: 12008: 12009: 792010: 802011: 1302012: 972013: 1692014: 2292015: 3782016: 3982017: 3682018: 4222019: 9942020: 3,6642021: 1,4222022: 2582023: 1432024: 1352025: 140
2007high 3,664 (2020) · low 1 (2007)2025

MAUDE reports naming product code OMP, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007611301
200889801
2009887779
2010697380
201161230130
201211292197
201311842169
2014101794229
2015201891378
2016191462398
2017111370368
2018132140422
2019152491994
2020617903,664
2021923801,422
2022102290258
202382910143
202491812135
202551270140
202691410—

What is it indicated for?

The 3M™ V.A.C.® Peel and Place Dressing is intended to be applied in an acute, extended, or home care setting where product application is conducted by or under the supervision of a qualified healthcare professional. It is an accessory to the 3M™ Negative Pressure Wound Therapy System. When used on open wounds, the system is intended to create an environment that promotes wound healing by secondary or tertiary (delayed primary) intention by preparing the…

Read the full statement (158 words)

The 3M™ V.A.C.® Peel and Place Dressing is intended to be applied in an acute, extended, or home care setting where product application is conducted by or under the supervision of a qualified healthcare professional. It is an accessory to the 3M™ Negative Pressure Wound Therapy System.

When used on open wounds, the system is intended to create an environment that promotes wound healing by secondary or tertiary (delayed primary) intention by preparing the wound bed for closure, reducing edema, promoting granulation tissue formation and perfusion, and by removing exudate and infectious material. Open wound types include: chronic, acute, traumatic, subacute and dehisced wounds, partial-thickness burns, ulcers (such as diabetic, pressure or venous insufficiency), flaps and grafts.

When used on closed surgical incisions, they are intended to manage the environment of surgical incisions that continue to drain following sutured or stapled closure by maintaining a closed environment and removing exudates via the application of negative pressure wound therapy.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K222859: 3M V.A.C. Peel and Place Dressing Kit, Small (EZ10SML), 3M V.A.C. Peel and Place Dressing Kit, Medium (EZ10MED), 3M V.A.C. Peel and Place Dressing Kit, Large (EZ10LRG).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K222859

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026