510(k) Report

510(k) · Cleared

Cleared

Access PCT

K222996510(k) TraditionalCleared Apr 26, 2023210-day reviewClass II21 CFR 866.3215

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Beckman Coulter, Inc. · PTF Assay To Measure Pct To Aid In The Risk Assessment Of Critically Ill Patients On Their First Day Of Icu Admission

Cleared on Apr 26, 2023 as substantially equivalent to K192271 (Beckman Coulter, Inc., 2019) after a 210-day review. Its family tree reaches back 4 generations to 2007.

Decided
Apr 26, 2023
Review
210 days
Class
Class II
Product code
PTF
Recalls
None
Predicates
1

Its longest line of descent runs back 4 generations to K071146 (2007). 5 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 4 generations backK071146 Vidas B.R.a.H.M.S. PCT AssaybioMerieux, Inc. · 2007 · Recalled
  2. 3 generations backK160911 Vidas B.R.a.H.M.S. PCT (PCT)bioMerieux, Inc. · 2016
  3. 2 generations backK162827 Vidas B.R.a.H.M.S. PCT (PCT)bioMerieux, Inc. · 2017
  4. 1 generation backK192271 Access PCT, Access PCT CalibratorsBeckman Coulter, Inc. · 2019 · Recalled
  5. This deviceK222996 Access PCTBeckman Coulter, Inc. · 2023
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K071146Vidas B.R.a.H.M.S. PCT AssaybioMerieux, Inc.20071
−3K160911Vidas B.R.a.H.M.S. PCT (PCT)bioMerieux, Inc.2016—
−2K162827Vidas B.R.a.H.M.S. PCT (PCT)bioMerieux, Inc.2017—
−1K192271Access PCT, Access PCT CalibratorsBeckman Coulter, Inc.20191
0 (this device)K222996Access PCTBeckman Coulter, Inc.2023—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
201610
FIG. 1 — Lineage of K222996, 2007–2023Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in PTF? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new PTF device

  1. #1 K242294 DiaSys Procalcitonin FS; DiaSys TruCal…score 9.3 · 1 generation · no Class I recall
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K192271Access PCT, Access PCT Calibrators
Summary page 5
…y Predicate Device: The Access PCT Assay/Calibrators claims substantial equivalence to previously cleared Access PCT Assay FDA 510(k) Number K192271. Device Description: The Access PCT assay is a paramagnetic, chemiluminescent immunoassay for in vitro quantitative determinat…
Beckman Coulter, Inc.20191

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 16 years and passes through 2 companies; a new generation was cleared every 3.4 years on median.
  • 2 of the 5 ancestors have a recall of any class.

How does its category compare?

All PTF devices

PTF Assay To Measure Pct To Aid In The Risk Assessment Of Critically Ill Patients On Their First Day Of Icu Admission: FDA decisions, review times, recalls and adverse event reports over 20 years. 2023, this device’s year, is highlighted.

FDA decisions per year · PTF

1in 2025

2017: 12019: 12023: 12025: 1
2007high 1 (2017) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · PTF

Too few PTF 510(k)s in any year since 2007 to give a median.

Recalls per year · PTF

No recall names PTF since 2007.

Adverse event reports per year · PTF

No MAUDE report names PTF since 2007.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20171—00
20180—00
20191—00
20200—00
20210—00
20220—00
20231—00
20240—00
20251—00
20260—0—

What is it indicated for?

The Access PCT assay is a paramagnetic, chemiluminescent immunoassay for in vitro quantitative determination of procalcitonin (PCT) levels in human serum and plasma (lithium heparin and EDTA) using the Access Immunoassay Systems. Measurement of PCT in conjunction with other laboratory findings and clinical assessments aids in the risk assessment of critically ill patients on their first day of Intensive Care Unit (ICU) admission for progression to severe sepsis and septic shock.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K222996: Access PCT.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K222996

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026