510(k) · Cleared
ClearedMenix®; Menix® Duo
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
S.B.M. Sas (Science & Bio Materials) · GAT Suture, Nonabsorbable, Synthetic, Polyethylene
Cleared on Aug 3, 2023 as substantially equivalent to K121861 (Smith & Nephew, Inc., 2012) after a 304-day review. Its family tree reaches back 4 generations to 2005.
- Decided
- Aug 3, 2023
- Review
- 304 days
- Class
- Class II
- Product code
- GAT
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 4 generations to K050021 (2005). 11 ancestors in all, the oldest K925573 (1993). No later device cites it as a predicate yet.
- Root · 4 generations backK050021 Vascular Solutions Vari-Lase Endovenous Laser Procedure KitVascular Solutions, Inc. · 2005
- 3 generations backK070216 Vari-Lase Bright Tip FiberVascular Solutions, Inc. · 2007
- 2 generations backK072332 Vari-Lase Wire FiberVascular Solutions, Inc. · 2008 · Recalled
- 1 generation backK121861 Smith & Nephew Ultra Fast-Fix Meniscal Repair System, Smith & Nephew…Smith & Nephew, Inc. · 2012
- This deviceK223122 Menix®; Menix® DuoS.B.M. Sas (Science & Bio Materials) · 2023
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −4 | K050021 | Vascular Solutions Vari-Lase Endovenous Laser Procedure Kit | Vascular Solutions, Inc. | 2005 | — |
| −3 | K070216 | Vari-Lase Bright Tip Fiber | Vascular Solutions, Inc. | 2007 | — |
| −2 | K072332 | Vari-Lase Wire Fiber | Vascular Solutions, Inc. | 2008 | 1 |
| −1 | K121861 | Smith & Nephew Ultra Fast-Fix Meniscal Repair System, Smith & Nephew Ultra… | Smith & Nephew, Inc. | 2012 | — |
| 0 (this device) | K223122 | Menix®; Menix® Duo | S.B.M. Sas (Science & Bio Materials) | 2023 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1993 | 1 | 0 |
| 1994 | 1 | 0 |
| 2000 | 1 | 0 |
| 2004 | 3 | 0 |
| 2010 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in GAT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new GAT device
- #1 K230311 HyperSuturescore 20.2 · 7 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K121861 | Smith & Nephew Ultra Fast-Fix Meniscal Repair System, Smith & Nephew Ultra Fast-Fix AB…Summary page 4…GAT 3. PREDICATE DEVICES (legally marketed devices to which equivalence is claimed) - FAST-FIX 360 Meniscal Repair System (K121861) Page 1 of 4 Traditional 510(k) MENIX® / MENIX® DUO K223122… | 2012 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 18 years and passes through 3 companies; a new generation was cleared every 4.8 years on median.
- 3 of the 11 ancestors have a recall of any class.
- 7 other devices also cite its predicate K121861.
How does its category compare?
All GAT devicesGAT Suture, Nonabsorbable, Synthetic, Polyethylene: FDA decisions, review times, recalls and adverse event reports over 20 years. 2023, this device’s year, is highlighted.
FDA decisions per year · GAT
5in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · GAT
30in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · GAT
1in 2011
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · GAT
2,956in 2025
MAUDE reports naming product code GAT, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 6 | 40 | 1 | 15 |
| 2008 | 4 | 93 | 0 | 15 |
| 2009 | 9 | 57 | 0 | 55 |
| 2010 | 11 | 27 | 3 | 79 |
| 2011 | 1 | — | 1 | 97 |
| 2012 | 6 | 61 | 0 | 253 |
| 2013 | 4 | 123 | 0 | 210 |
| 2014 | 4 | 45 | 0 | 165 |
| 2015 | 7 | 125 | 0 | 626 |
| 2016 | 10 | 139 | 0 | 688 |
| 2017 | 6 | 57 | 0 | 1,104 |
| 2018 | 6 | 95 | 0 | 1,453 |
| 2019 | 4 | 79 | 0 | 1,251 |
| 2020 | 5 | 201 | 0 | 1,220 |
| 2021 | 4 | 92 | 0 | 1,643 |
| 2022 | 5 | 109 | 0 | 1,419 |
| 2023 | 8 | 220 | 0 | 2,038 |
| 2024 | 3 | 140 | 0 | 2,597 |
| 2025 | 5 | 30 | 0 | 2,956 |
| 2026 | 5 | 83 | 0 | — |
What is it indicated for?
The MENIX® / MENIX® DUO Meniscal Suture Systems are indicated for use as suture retention devices to facilitate percutaneous or endoscopic soft tissue procedures. The MENIX® / MENIX® DUO systems are indicated for use in meniscal repairs and allograft transplant procedures. The MENIX® / MENIX® DUO systems are intended to be used for anchoring the allograft to the meniscal rim during allograft transplant procedures.
The MENIX ® / MENIX® DUO devices are intended for single use only.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K223122 · printed Nov 4, 2026
Cite this page
510(k) Report. “K223122: Menix®; Menix® Duo.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K223122
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026