510(k) Report

510(k) · Cleared

Cleared

MAVEN™ Patient-Specific Instrumentation

K223227510(k) SpecialCleared Nov 17, 202230-day reviewClass II21 CFR 888.3110

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Paragon 28, Inc. · HSN Prosthesis, Ankle, Semi-Constrained, Cemented, Metal/Polymer

Cleared on Nov 17, 2022 as substantially equivalent to K202019 (Paragon 28, Inc., 2021) after a 30-day review. Its family tree reaches back 10 generations to 1992.

Decided
Nov 17, 2022
Review
30 days
Class
Class II
Product code
HSN
Recalls
None
Predicates
2

Its longest line of descent runs back 10 generations to K920802 (1992). 36 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 10 generations backK920802 Alvine Total AnkleDepuy, Inc. · 1992
  2. 6 generations between
  3. 3 generations backK162795 PROPHECY INVISION Preoperative Navigation Alignment SystemWrightmedicaltechnologyinc · 2017
  4. 2 generations backK170968 PROPHECY INVISION Pre-operative Navigation SystemWrightmedicaltechnologyinc · 2017
  5. 1 generation backK202019 Maven Patient-Specific InstrumentationParagon 28, Inc. · 2021
  6. This deviceK223227 MAVEN™ Patient-Specific InstrumentationParagon 28, Inc. · 2022
Show all 10 generations
  1. Root · 10 generations backK920802 Alvine Total AnkleDepuy, Inc. · 1992
  2. 9 generations backK020541 Agility Ankle Revision ProsthesisDepuy, Inc. · 2002
  3. 8 generations backK051023 Topez Total Ankle ReplacementTopez Orthopedics, Inc. · 2005 · Recalled
  4. 7 generations backK100886 Inbone II Total Ankle ReplacementWrightmedicaltechnologyinc · 2010 · Recalled
  5. 6 generations backK123954 Infinity Total Ankle SystemWrightmedicaltechnologyinc · 2013 · Recalled
  6. 5 generations backK133585 Inbone Total AnkleWrightmedicaltechnologyinc · 2014
  7. 4 generations backK142117 Invision Total Ankle Revision SystemWrightmedicaltechnologyinc · 2015
  8. 3 generations backK162795 PROPHECY INVISION Preoperative Navigation Alignment SystemWrightmedicaltechnologyinc · 2017
  9. 2 generations backK170968 PROPHECY INVISION Pre-operative Navigation SystemWrightmedicaltechnologyinc · 2017
  10. 1 generation backK202019 Maven Patient-Specific InstrumentationParagon 28, Inc. · 2021
  11. This deviceK223227 MAVEN™ Patient-Specific InstrumentationParagon 28, Inc. · 2022
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−10K920802Alvine Total AnkleDepuy, Inc.1992—
−9K020541Agility Ankle Revision ProsthesisDepuy, Inc.2002—
−8K051023Topez Total Ankle ReplacementTopez Orthopedics, Inc.20054
−7K100886Inbone II Total Ankle ReplacementWrightmedicaltechnologyinc20102
−6K123954Infinity Total Ankle SystemWrightmedicaltechnologyinc20132
−5K133585Inbone Total AnkleWrightmedicaltechnologyinc2014—
−4K142117Invision Total Ankle Revision SystemWrightmedicaltechnologyinc2015—
−3K162795PROPHECY INVISION Preoperative Navigation Alignment SystemWrightmedicaltechnologyinc2017—
−2K170968PROPHECY INVISION Pre-operative Navigation SystemWrightmedicaltechnologyinc2017—
−1K202019Maven Patient-Specific InstrumentationParagon 28, Inc.2021—
0 (this device)K223227MAVEN™ Patient-Specific InstrumentationParagon 28, Inc.2022—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199510
199810
199920
200020
200220
200410
200510
200630
200910
201010
201110
201330
201410
201520
201620
201710
202010
FIG. 1 — Lineage of K223227, 1992–2022Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HSN? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new HSN device

  1. #1 K192994 Paragon 28 APEX 3D Total Ankle Replacement…score 16.7 · 8 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary; numbers the summary cites that cannot be its predicate are marked – and kept off the family tree.

TypeNumberDeviceApplicantDecidedRecalls
*K202019Maven Patient-Specific Instrumentation
Summary page 4
…ice is to allow an additional material and supplier to make the subject device. Intended Use The intended use and indication are the same as the main predicate device, K202019. Indications are: The MAVEN™ Patient-Specific Instrumentation System is intended to be used as patient specific…
Paragon 28, Inc.2021—
Kept off the family treeK211076FDA’s K211076 is Patient Specific Marking Guides
Not matched in our reading of the summary (scans can blur digits), so it is kept off the family tree
Additive Orthopaedics, LLC2022—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 30 years and passes through 4 companies; a new generation was cleared every 2.6 years on median.
  • 15 of the 36 ancestors have a recall of any class.

How does its category compare?

All HSN devices

HSN Prosthesis, Ankle, Semi-Constrained, Cemented, Metal/Polymer: FDA decisions, review times, recalls and adverse event reports over 20 years. 2022, this device’s year, is highlighted.

FDA decisions per year · HSN

3in 2025

2009: 12010: 22011: 12012: 22013: 42014: 22015: 32016: 32017: 42018: 42019: 22020: 62021: 42022: 12023: 62024: 72025: 32026 (partial year): 2
2007high 7 (2024) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HSN

58in 2025

2013: 89 days median2015: 233 days median2016: 216 days median2017: 148 days median2018: 89 days median2020: 234 days median2021: 109 days median2023: 112 days median2024: 115 days median2025: 58 days median
2007high 234 (2020) · low 58 (2025)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · HSN

1in 2023

2013: 32016: 12017: 22019: 12021: 32022: 22023: 1
2007high 3 (2013) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · HSN

1,645in 2025

2007: 502008: 662009: 662010: 1202011: 1392012: 1002013: 1062014: 652015: 732016: 1112017: 962018: 1872019: 2772020: 2812021: 2372022: 4532023: 7962024: 1,0952025: 1,645
2007high 1,645 (2025) · low 50 (2007)2025

MAUDE reports naming product code HSN, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—050
20080—066
20091—066
20102—0120
20111—0139
20122—0100
20134893106
20142—065
20153233073
201632161111
20174148296
20184890187
20192—1277
202062340281
202141093237
20221—2453
202361121796
2024711501,095
202535801,645
20262—0—

What is it indicated for?

The MAVEN™ Patient-Specific Instrumentation System is intended to be used as patient specific surgical instrumentation to assist in the positioning of total ankle replacement components intraoperatively and in guiding the marking of bone before cutting. The MAVEN™ Patient-Specific Instrumentation System is intended for use with the Paragon 28® APEX 3D™ Total Ankle Replacement System and its cleared indications for use, provided that anatomic landmarks…

Read the full statement (136 words)

The MAVEN™ Patient-Specific Instrumentation System is intended to be used as patient specific surgical instrumentation to assist in the positioning of total ankle replacement components intraoperatively and in guiding the marking of bone before cutting. The MAVEN™ Patient-Specific Instrumentation System is intended for use with the Paragon 28® APEX 3D™ Total Ankle Replacement System and its cleared indications for use, provided that anatomic landmarks necessary for alignment and positioning of the implant are identifiable on patient imaging CT scans. The MAVEN™ Patient-Specific Instrumentation System is intended for single use only. The Paragon 28® TAR Patient-Specific Case Reports are intended for use with the Paragon 28® APEX 3D™ Total Ankle Replacement System and its cleared indications for use, provided that anatomic landmarks necessary for alignment and positioning of the implant are identifiable on patient imaging CT scans.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K223227: MAVEN™ Patient-Specific Instrumentation.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K223227

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026