510(k) · Cleared
ClearediExaminer System with Panoptic Plus
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Welch Allyn, Inc. · HKI Camera, Ophthalmic, Ac-Powered
Cleared on Mar 15, 2023 as substantially equivalent to K121405 (Welch Allyn, Inc., 2012) after a 128-day review. Its family tree reaches back 4 generations to 2001.
- Decided
- Mar 15, 2023
- Review
- 128 days
- Class
- Class II
- Product code
- HKI
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 4 generations to K003376 (2001). 15 ancestors in all, the oldest K912891 (1991). No later device cites it as a predicate yet.
- Root · 4 generations backK003376 Welch Allyn 11800 OpthalmoscopeWelch Allyn, Inc. · 2001
- 3 generations backK092056 Optomed Smartscope, Model M3-1 EY1Optomed OY · 2009
- 2 generations backK110986 Optomed Smartscope M5 EY3 and M5 ES1Optomed OY · 2011
- 1 generation backK121405 PanopticWelch Allyn, Inc. · 2012
- This deviceK223381 iExaminer System with Panoptic PlusWelch Allyn, Inc. · 2023
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −4 | K003376 | Welch Allyn 11800 Opthalmoscope | Welch Allyn, Inc. | 2001 | — |
| −3 | K092056 | Optomed Smartscope, Model M3-1 EY1 | Optomed OY | 2009 | — |
| −2 | K110986 | Optomed Smartscope M5 EY3 and M5 ES1 | Optomed OY | 2011 | — |
| −1 | K121405 | Panoptic | Welch Allyn, Inc. | 2012 | — |
| 0 (this device) | K223381 | iExaminer System with Panoptic Plus | Welch Allyn, Inc. | 2023 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1991 | 2 | 0 |
| 1993 | 1 | 0 |
| 1995 | 3 | 0 |
| 1998 | 1 | 0 |
| 2005 | 1 | 0 |
| 2006 | 1 | 0 |
| 2008 | 1 | 0 |
| 2011 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in HKI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new HKI device
- #1 K253176 TearViewscore 12.7 · 5 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K121405 | PanopticSummary page 5…Table 2. Predicate Device Device Company Predicate 510(k) Clearance Date iExaminer with Welch Allyn, Inc. K121405 December 20, 2012 PanOptic Description of the Device The iExaminer System with PanOptic Plus is a medical device… | 2012 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 22 years and passes through 2 companies; a new generation was cleared every 8.7 years on median.
- 1 of the 15 ancestors has a recall of any class.
How does its category compare?
All HKI devicesHKI Camera, Ophthalmic, Ac-Powered: FDA decisions, review times, recalls and adverse event reports over 20 years. 2023, this device’s year, is highlighted.
FDA decisions per year · HKI
4in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · HKI
167in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · HKI
1in 2018
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · HKI
1in 2023
MAUDE reports naming product code HKI, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 2 | — | 0 | 3 |
| 2008 | 5 | 29 | 0 | 1 |
| 2009 | 11 | 104 | 0 | 1 |
| 2010 | 6 | 140 | 0 | 0 |
| 2011 | 7 | 160 | 0 | 0 |
| 2012 | 5 | 179 | 1 | 2 |
| 2013 | 7 | 141 | 0 | 22 |
| 2014 | 4 | 135 | 0 | 3 |
| 2015 | 0 | — | 0 | 3 |
| 2016 | 4 | 146 | 1 | 66 |
| 2017 | 2 | — | 1 | 20 |
| 2018 | 6 | 71 | 1 | 14 |
| 2019 | 4 | 73 | 0 | 0 |
| 2020 | 5 | 182 | 0 | 5 |
| 2021 | 4 | 155 | 0 | 3 |
| 2022 | 1 | — | 0 | 1 |
| 2023 | 5 | 259 | 0 | 1 |
| 2024 | 3 | 28 | 0 | 0 |
| 2025 | 4 | 167 | 0 | 0 |
| 2026 | 2 | — | 0 | — |
What is it indicated for?
The iExaminer system with PanOptic Plus, consisting of PanOptic Plus, SmartBracket, SmartClip, iExaminer application, and one of the following: iPhone X, iPhone 11 Pro, iPhone 11 Pro Max, iPhone 12 Pro, is intended to be used to capture images as an aid to clinicians in the evaluation, and documentation of ocular health. The images from the iExaminer System with PanOptic Plus are not intended to be used as a sole means of diagnosis.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K223381 · printed Nov 6, 2026
Cite this page
510(k) Report. “K223381: iExaminer System with Panoptic Plus.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K223381
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026