# K223476: V-PRO maX 2 Low Temperature Sterilization System

- Pathway: 510(k) (Traditional)
- Applicant: STERIS Corporation
- Decided: Aug 7, 2023 after 262 days
- Product code: MLR (Sterilizer, Chemical)
- Device class: 2
- Regulation: 21 CFR 880.6860
- Recalls of this device: none
- Data: FDA decisions to Oct 25, 2026; recalls to Oct 12, 2026

## Lineage
Longest line of descent: 2 generations back to K190103 (2019). 2 ancestors in all.
1 later device descends from it; 1 cites it directly.
0 of 4 devices in its family (counting itself) have a Class I recall.

## Predicates on the family tree (from the FDA summary)
- K222093: V-PRO maX 2 Low Temperature Sterilization System, V-PRO maX Low Temperature Sterilization System, Steris (2022) Summary page 6.

## Most influential descendants
- K233065: V-PRO maX 2 Low Temperature Sterilization System (2023), 0 descendants of its own

## Indications for use
The V-PRO maX 2 Low Temperature Sterilization System using VAPROX HC Sterilant is intended for use in the terminal sterilization of properly prepared (cleaned, rinsed and dried) medical devices in Healthcare Facilities. The preprogrammed sterilization cycles operate at low pressure and temperature, suitable for processing medical devices without leaving toxic residues. Each Cycle can sterilize non-lumened instruments with diffusion-restricted spaces such as the hinged portion of forceps and scissors. The Non Lumen Cycle can sterilize: ‡ Non-lumened instruments including non-lumened general medical instruments, non-lumened rigid, semi-rigid and flexible endoscopes. ‡ The validation studies were conducted using a validation load consisting of two instrument trays for a total weight of 50 lbs (22.7 kg). The Fast Non Lumen Cycle can sterilize:* Non-lumened instruments including non-lumened general medical instruments, non-lumened rigid, semi-rigid and flexible endoscopes. * The validation studies were conducted using a validation load consisting of one pouched instrument tray for a total weight of 11 lbs (5 kg). The Flexible Cycle can sterilize: Single or dual lumen surgical flexible endoscopes (such as those used in ENT, Urology and Surgical Care) and bronchoscopes in either of the two configurations: 1. Two flexible endoscopes with a light cord (if not integral to endoscope) and mat with no additional load.* The flexible endoscopes may contain single or dual channel lumens that are ≥ 1 mm internal diameter (ID) and ≤ 1050 mm in length. * The validation studies were conducted with two flexible endoscopes, each packaged into a tray with silicone mat and light cord (if not integral to endoscope). 2. One flexible endoscope with a light cord (if not integral to endoscope) and mat and additional non-lumened instruments. †† The flexible endoscope may contain single or dual channel lumens that are ≥ 1 mm ID and ≤ 1050 mm in length Additional instruments may include non-lumened or lumened medical devices with the following configurations: Single, dual or triple channel stainless steel lumen that is ≥ 0.48 mm ID and ≤ 100 mm in length †† The validation studies were conducted with a flexible endoscope in a tray with endoscope accessories, silicone mat, light cord (if not integral to endoscope) and 5 stainless steel lumens. Also included in the load was a tray with additional instruments, and silicone mat for a total weight of 24 lbs (11 kg). The Lumen Cycle can sterilize: † Medical devices with the following configurations: • Single, dual or triple channeled stainless steel lumen that are: • ≥ 0.77 mm ID and ≤ 527 mm in length • ≥ 0.8 mm ID and ≤ 542 mm in length • ≥ 0.48 mm ID and ≤ 100 mm in length • Dead end lumen that is ≥ 1.3 mm ID and ≤ 73 mm in length • Rigid non-metallic lumen (such as those used in endoscope sheaths, take-apart forceps and trocars) that are: • ≥ 3 mm ID and ≤ 298 mm in length • ≥ 4 mm ID and ≤ 424 mm in length † Validation testing for all lumen sizes was conducted using a maximum of 20 lumens per load. Hospital loads should not exceed the maximum number of lumens validated by this testing. The validation studies were performed using a validation load consisting of two instrument trays and two pouches for a total weight of 19.65 lbs (8.9 kg). The Specialty Cycle can sterilize: Non-lumened instruments including non-lumened general medical instruments, non-lumened rigid, semi-rigid and flexible endoscopes.* * The validation studies were conducted using a validation load consisting of one pouched instrument tray or one pouch with guide(s)/model(s) (with or without tray) for a total weight of 11 lbs (5 kg). or Patient-specific surgical guides (e.g. osteotomy, shoulder, hip, knee, spine) or anatomical models fabricated via additive manufacturing (3D printing) processes and intended for single-use during operative procedures.** ** The validation studies were conducted using a validation load consisting of pouched guide(s)/model(s) (with or without tray) for a total weight of 5 lbs (2.3 kg) 3D printed material. Devices used in validation studies were prepared in accordance with printer manufacturers’ instructions for use, to include printing, curing, removal of support material and cleaning. Material Manufacturer Specialty Cycle Lumens Surgical Guide Resin Formlabs F ≥3 mm ID x ≤30 mm L BioMed Amber Resin Formlabs F ≥3 mm ID x ≤30 mm L Dental LT Clear V2 Resin Formlabs D ≥3 mm ID x ≤30 mm L BioMed Clear Resin Formlabs D ≥3 mm ID x ≤30 mm L Biocompatible Clear MED610 Stratasys E ≥3 mm ID x ≤20 mm L Biocompatible Opaque MED615RGD Stratasys E ≥3 mm ID x ≤20 mm L VeroGlaze™ MED620 Stratasys E ≥3 mm ID x ≤20 mm L