510(k) Report

510(k) · Cleared

Cleared

PBC Separator with Selux AST System

K223493510(k) TraditionalCleared Feb 15, 2024451-day reviewClass II21 CFR 866.1650

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Selux Diagnostics, Inc. · QZX Positive Blood Culture Processor For Inoculum Preparation Used For Antimicrobial Susceptibility Testing

Cleared on Feb 15, 2024 as substantially equivalent to K231536 (Avails Medical, Inc., 2024) after a 451-day review. Its family tree reaches back 3 generations to 2017. 1 later device descends from it.

Decided
Feb 15, 2024
Review
451 days
Class
Class II
Product code
QZX
Recalls
None
Predicates
1

Its longest line of descent runs back 3 generations to DEN160032 (2017). 1 later device descends from it, 1 citing it directly.

  1. Root · 3 generations backDEN160032 Accelerate Pheno system, Accelerate Phenotest BC KitAccelerate Diagnotics · 2017
  2. 2 generations backK192665 Accelerate Pheno System, Accelerate PhenoTest BC KitAccelerate Diagnostics, Inc. · 2020 · Recalled
  3. 1 generation backK231536 eQUANT SystemAvails Medical, Inc. · 2024
  4. This deviceK223493 PBC Separator with Selux AST SystemSelux Diagnostics, Inc. · 2024
  5. Descendant · cites it directly · 0 of its ownK244044 PBC Separator with Selux AST SystemSelux Diagnostics, Inc. · 2025

Most influential descendants

Showing 1 of 1 · See all
  • K244044PBC Separator with Selux AST SystemSelux Diagnostics, Inc. · 2025 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−3DEN160032Accelerate Pheno system, Accelerate Phenotest BC KitAccelerate Diagnotics2017—
−2K192665Accelerate Pheno System, Accelerate PhenoTest BC KitAccelerate Diagnostics, Inc.20202
−1K231536eQUANT SystemAvails Medical, Inc.2024—
0 (this device)K223493PBC Separator with Selux AST SystemSelux Diagnostics, Inc.2024—
+1K244044PBC Separator with Selux AST SystemSelux Diagnostics, Inc.2025—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202510
FIG. 1 — Lineage of K223493, 2017–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in QZX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new QZX device

  1. #1 K231536 eQUANT Systemscore 10.1 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K231536eQUANT System
Cleared while this submission was under review
Summary page 6
…LTW Classification Panel: 83 (Microbiology) Predicate Device Trade Name: eQUANT System Manufacturer: Avails Medical, Inc. 510(k) Reference: K231536 Common Name: eQUANT System Regulation Number: 21 CFR 866.1650 Regulation Name: Positive Blood Culture Iden…
Avails Medical, Inc.2024—

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K244044PBC Separator with Selux AST SystemSelux Diagnostics, Inc.20250

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 7 years and passes through 4 companies; a new generation was cleared every 3.4 years on median.
  • 1 of the 3 ancestors has a recall of any class.
  • Of its descendants, K244044 (Selux Diagnostics, Inc., 2025) has gone furthest, with 0 descendants of its own.

How does its category compare?

All QZX devices

QZX Positive Blood Culture Processor For Inoculum Preparation Used For Antimicrobial Susceptibility Testing: FDA decisions, review times, recalls and adverse event reports over 20 years. 2024, this device’s year, is highlighted.

FDA decisions per year · QZX

1in 2025

2024: 22025: 1
2007high 2 (2024) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · QZX

Too few QZX 510(k)s in any year since 2007 to give a median.

Recalls per year · QZX

No recall names QZX since 2007.

Adverse event reports per year · QZX

No MAUDE report names QZX since 2007.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20180—00
20190—00
20200—00
20210—00
20220—00
20230—00
20242—00
20251—00
20260—0—

What is it indicated for?

The PBC Separator with Selux AST System is an automated inoculum preparation system that uses lysis, centrifugation and sequential optical density measurements to generate a McFarland-equivalent suspension from positive blood culture samples that can be used for quantitative in vitro antimicrobial susceptibility testing by the Selux AST System. Samples are processed directly from blood culture samples identified as positive by a continuous monitoring…

Read the full statement (480 words)

The PBC Separator with Selux AST System is an automated inoculum preparation system that uses lysis, centrifugation and sequential optical density measurements to generate a McFarland-equivalent suspension from positive blood culture samples that can be used for quantitative in vitro antimicrobial susceptibility testing by the Selux AST System. Samples are processed directly from blood culture samples identified as positive by a continuous monitoring blood culture system. Samples should be confirmed as monomicrobial, gram negative rods by Gram stain. Organism identification is required for AST result interpretation and reporting, per the Selux AST System instructions for use.

Inoculum preparation by the PBC Separator was evaluated for use with the Selux AST System. Performance was demonstrated for the antimicrobial agents and organisms identified below:

Amikacin: Acinetobacter baumannii complex, Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa

Amoxicillin-Clavulanate: Escherichia coli, Klebsiella species (including K. oxytoca, K. pneumoniae), Proteus mirabilis, Proteus vulgaris

Ampicillin: Escherichia coli, Proteus mirabilis

Ampicillin-Sulbactam: Acinetobacter baumannii complex, Citrobacter koseri, Escherichia coli, Klebsiella pneumoniae, Proteus mirabilis

Cefazolin: Escherichia coli, Klebsiella pneumoniae

Cefepime: Citrobacter freundii complex, Citrobacter koseri, Enterobacter cloacae complex, Escherichia coli, Klebsiella aerogenes, Klebsiella oxytoca, Klebsiella pneumoniae, Morganella morganii, Proteus mirabilis, Proteus vulgaris, Serratia marcescens, Pseudomonas aeruginosa

Ceftazidime: Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa

Ceftazidime-Avibactam: Citrobacter freundii complex, Citrobacter koseri, Enterobacter cloacae complex, Escherichia coli, Klebsiella aerogenes, Klebsiella oxytoca, Klebsiella pneumoniae, Morganella morganii, Proteus mirabilis, Proteus vulgaris, Serratia marcescens, Pseudomonas aeruginosa

Ceftriaxone: Citrobacter freundii complex, Citrobacter koseri, Enterobacter cloacae complex, Escherichia coli, Klebsiella aerogenes, Klebsiella oxytoca, Klebsiella pneumoniae, Proteus mirabilis, Serratia marcescens

Ciprofloxacin: Citrobacter freundii complex, Citrobacter koseri, Enterobacter cloacae complex, Escherichia coli, Klebsiella aerogenes, Klebsiella oxytoca, Klebsiella pneumoniae, Morganella morganii, Proteus mirabilis, Proteus vulgaris, Serratia marcescens, Pseudomonas aeruginosa

Ertapenem: Citrobacter freundii complex, Citrobacter koseri, Enterobacter cloacae complex, Escherichia coli, Klebsiella aerogenes, Klebsiella oxytoca, Klebsiella pneumoniae, Morganella morganii, Proteus mirabilis, Proteus vulgaris, Serratia marcescens

Gentamicin: Citrobacter freundii complex, Citrobacter koseri, Enterobacter cloacae complex, Escherichia coli, Klebsiella aerogenes, Klebsiella oxytoca, Klebsiella pneumoniae, Morganella morganii, Proteus mirabilis, Proteus vulgaris, Serratia marcescens, Pseudomonas aeruginosa

Imipenem: Acinetobacter baumannii complex, Escherichia coli, Klebsiella pneumoniae

Meropenem: Acinetobacter baumannii complex, Citrobacter freundii complex, Citrobacter koseri, Enterobacter cloacae complex, Escherichia coli, Klebsiella oxytoca, Klebsiella pneumoniae, Morganella morganii, Proteus mirabilis, Proteus vulgaris, Serratia marcescens, Pseudomonas aeruginosa

Minocycline: Acinetobacter baumannii complex, Escherichia coli, Klebsiella pneumoniae

Piperacillin-Tazobactam: Acinetobacter baumannii complex, Citrobacter koseri, Escherichia coli, Klebsiella pneumoniae, Morganella morganii, Proteus mirabilis, Proteus vulgaris, Serratia marcescens, Pseudomonas aeruginosa

Tobramycin: Escherichia coli, Klebsiella pneumoniae, Pseudomonas aeruginosa

Susceptibility test results are intended to be used in conjunction with other clinical and laboratory findings. Standard laboratory protocols for processing positive blood cultures should be followed to ensure availability of isolates for supplemental testing as needed. Additionally, subculture of positive blood culture is necessary for the susceptibility testing of organisms present in polymicrobial samples, for testing antimicrobial agents and species not indicated for testing with the device, for epidemiologic testing, and for recovery of organisms present in microbial samples.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K223493: PBC Separator with Selux AST System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K223493

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026