510(k) Report

510(k) · Cleared

Cleared

Traumatic brain injury (TBI) test

K223602510(k) TraditionalCleared Mar 2, 202390-day reviewClass II21 CFR 866.5830

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Abbott Laboratories · QAT Brain Trauma Assessment Test

Cleared on Mar 2, 2023 as substantially equivalent to DEN170045 (Banyan Biomarkers, Inc., 2018) after a 90-day review. Its family tree reaches back 1 generation to 2018. 1 later device descends from it.

Decided
Mar 2, 2023
Review
90 days
Class
Class II
Product code
QAT
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to DEN170045 (2018). 1 later device descends from it, 1 citing it directly.

Descendants, by year cleared 2023: 1 descendant clearedDEN170045 · Banyan BTI · Banyan Biomarkers, Inc. · 2018201620182020202220242026
Descendants, by generation 1 generation forward: 1 descendant DEN170045 · Banyan BTI · Banyan Biomarkers, Inc. · 20180
  1. Root · 1 generation backDEN170045 Banyan BTIBanyan Biomarkers, Inc. · 2018
  2. This deviceK223602 Traumatic brain injury (TBI) testAbbott Laboratories · 2023
  3. Descendant · cites it directly · 0 of its ownK232669 TBIAbbott Laboratories · 2023

Most influential descendants

Showing 1 of 1 · See all
  • K232669TBIAbbott Laboratories · 2023 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1DEN170045Banyan BTIBanyan Biomarkers, Inc.2018—
0 (this device)K223602Traumatic brain injury (TBI) testAbbott Laboratories2023—
+1K232669TBIAbbott Laboratories2023—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202310
FIG. 1 — Lineage of K223602, 2018–2023Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in QAT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new QAT device

  1. #1 K234143 i-STAT TBI Cartridge with the i-STAT Alinity…score 7.4 · 2 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*DEN170045Banyan BTI
Summary page 5
…5 === Attachment B III. Predicate Device Banyan Brain Trauma Indicator (BTI) (DEN170045) IV. Description of Device Reagents The kit configurations of the GFAP and UCH-L1 reagent kits are described b…
Banyan Biomarkers, Inc.2018—

Also cleared against DEN170045: 2 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K232669TBIAbbott Laboratories20230

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • Of its descendants, K232669 (Abbott Laboratories, 2023) has gone furthest, with 0 descendants of its own.
  • 2 other devices also cite its predicate DEN170045.

How does its category compare?

All QAT devices

QAT Brain Trauma Assessment Test: FDA decisions, review times, recalls and adverse event reports over 20 years. 2023, this device’s year, is highlighted.

FDA decisions per year · QAT

2in 2024

2018: 12021: 12023: 22024: 2
2007high 2 (2023) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · QAT

Too few QAT 510(k)s in any year since 2007 to give a median.

Recalls per year · QAT

No recall names QAT since 2007.

Adverse event reports per year · QAT

No MAUDE report names QAT since 2007.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20181—00
20190—00
20200—00
20211—00
20220—00
20232—00
20242—00
20250—00
20260—0—

What is it indicated for?

The TBI test is a panel of in vitro diagnostic chemiluminescent microparticle immunoassays (CMIA) used for the quantitative measurements of glial fibrillary acidic protein (GFAP) and ubiquitin carboxyl-terminal hydrolase L1 (UCH-L1) in human plasma and serum and provides a semi-quantitative interpretation of test results derived from these measurements using the Alinity i system. The interpretation of test results is used, in conjunction with other…

Read the full statement (144 words)

The TBI test is a panel of in vitro diagnostic chemiluminescent microparticle immunoassays (CMIA) used for the quantitative measurements of glial fibrillary acidic protein (GFAP) and ubiquitin carboxyl-terminal hydrolase L1 (UCH-L1) in human plasma and serum and provides a semi-quantitative interpretation of test results derived from these measurements using the Alinity i system.

The interpretation of test results is used, in conjunction with other clinical information, to aid in the evaluation of patients, 18 years of age or older, presenting with suspected mild traumatic brain injury (Glasgow Coma Scale score 13-15) within 12 hours of injury, to assist in determining the need for a CT (computed tomography) scan of the head. A negative test result is associated with the absence of acute intracranial lesions visualized on a head CT scan.

The TBI test is intended for use in clinical laboratory settings by healthcare professionals.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K223602: Traumatic brain injury (TBI) test.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K223602

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026