Sonoclot Coagulation & Platelet Function Analyzer System with Sonoclot Viewer

K223635510(k) SpecialCleared Jan 4, 202330-day reviewClass II21 CFR 864.7140

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Sienco, Inc. · JBP Activated Whole Blood Clotting Time

Cleared on Jan 4, 2023 as substantially equivalent to K002528 (Sienco, Inc., 2000) and 1 other predicate after a 30-day review. Its family tree reaches back 1 generation to 1995.

Decided
Jan 4, 2023
Review
30 days
Class
Class II
Product code
JBP
Recalls
None
Predicates
2

Its longest line of descent runs back 1 generation to K952560 (1995). 2 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 2000: 1 other ancestorK952560 · Sonoclot Coagulation & Platelet Function Analyzer · Sienco, Inc. · 19951995200020052010201520202025
Other ancestors, by generation 1 generation back: 1 other ancestor K952560 · Sonoclot Coagulation & Platelet Function Analyzer · Sienco, Inc. · 19950
  1. Root · 1 generation backK952560 Sonoclot Coagulation & Platelet Function AnalyzerSienco, Inc. · 1995
  2. This deviceK223635 Sonoclot Coagulation & Platelet Function Analyzer System with…Sienco, Inc. · 2023
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K952560Sonoclot Coagulation & Platelet Function AnalyzerSienco, Inc.1995—
0 (this device)K223635Sonoclot Coagulation & Platelet Function Analyzer System with Sonoclot ViewerSienco, Inc.2023—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200010
FIG. 1 — Lineage of K223635, 1995–2023Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in JBP? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K002528Sonoclot Coagulation & Platelet Function Analyzer System with Signature Viewer Option
Summary page 4
…Predicate Trade Name (Primary predicate is listed first) Product Code Sonoclot Coagulation & Platelet Function Analyzer System with Signature K002528 JBP Viewer Option K952560…
Sienco, Inc.2000—
*K952560Sonoclot Coagulation & Platelet Function Analyzer
Summary page 4
…atelet Function Analyzer System with Signature K002528 JBP Viewer Option K952560 Sonoclot Coagulation & Platelet Function Analyzer JPA Device Description Summary…
Sienco, Inc.1995—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • None of the 2 ancestors has a recall.

How does its category compare?

All JBP devices

JBP Activated Whole Blood Clotting Time: FDA decisions, review times, recalls and adverse event reports over 20 years. 2023, this device’s year, is highlighted.

FDA decisions per year · JBP

1in 2023

2007: 12023: 1
2007high 1 (2007) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · JBP

Too few JBP 510(k)s in any year since 2007 to give a median.

Recalls per year · JBP

2in 2025

2009: 32010: 32025: 2
2007high 3 (2009) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · JBP

18in 2025

2007: 52008: 62009: 292010: 242011: 112012: 252013: 322014: 32015: 262016: 42017: 162018: 12019: 152020: 102021: 92022: 72023: 162024: 232025: 18
2007high 32 (2013) · low 1 (2018)2025

MAUDE reports naming product code JBP, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—05
20080—06
20090—329
20100—324
20110—011
20120—025
20130—032
20140—03
20150—026
20160—04
20170—016
20180—01
20190—015
20200—010
20210—09
20220—07
20231—016
20240—023
20250—218
20260—0—

What is it indicated for?

The Sonoclot Coagulation & Platelet Function Analyzer System is an in vitro diagnostic device for measuring coagulation and platelet function. This system has two configurations. The historic configuration is a Sonoclot Analyzer connected to a thermal graphics printer. The standard configuration is a Sonoclot Analyzer connected to a computer running Sonoclot Viewer data collection software. The Sonoclot Analyzer System rapidly provides information on the…

Read the full statement (149 words)

The Sonoclot Coagulation & Platelet Function Analyzer System is an in vitro diagnostic device for measuring coagulation and platelet function. This system has two configurations. The historic configuration is a Sonoclot Analyzer connected to a thermal graphics printer. The standard configuration is a Sonoclot Analyzer connected to a computer running Sonoclot Viewer data collection software.

The Sonoclot Analyzer System rapidly provides information on the entire hemostasis process including coagulation, fibrin gel formation, clot retraction (platelet function) and fibrinolysis.

The Sonoclot Analyzer System generates a qualitative graph, known a the Sonoclot Signature, and quantitative results on the clot formation time (Activated Clotting Time-Onset), the rate of fibrin polymerization (Clot Rate), and clot retraction (Platelet Function). This information can be used to identify numerous coagulopathies including platelet dysfunction, factor deficiencies, anticoagulant effect, hypercoagulable tendencies and hyperfibrinolysis. Different disposable tests are available for use with the Sonoclot Analyzer System for different applications.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K223635: Sonoclot Coagulation & Platelet Function Analyzer System with Sonoclot Viewer.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K223635

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026