Disposable Needle Guides and Grids

K223689510(k) TraditionalCleared Aug 2, 2023236-day reviewClass II21 CFR 892.1570

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Advance Medical Designs, Inc. · ITX Transducer, Ultrasonic, Diagnostic

Cleared on Aug 2, 2023 as substantially equivalent to K970514 (CIVCO Medical Instruments Co., Inc., 1997) after a 236-day review. Its family tree reaches back 2 generations to 1988. 1 later device descends from it.

Decided
Aug 2, 2023
Review
236 days
Class
Class II
Product code
ITX
Recalls
None
Predicates
1

Its longest line of descent runs back 2 generations to K875128 (1988). 3 ancestors in all. 1 later device descends from it, 1 citing it directly.

Other ancestors, by generationDescendants, by generation 2 generations back: 1 other ancestor 1 generation forward: 1 descendant K970514 · Disposable Transrectal/Transvaginal/Endocavity Ultrasound Needle Instrument Guide · CIVCO Medical Instruments Co., Inc. · 1997 · recalledK875128 · Trans/R Needle Guide · CIVCO Medical Instruments Co., Inc. · 19880
  1. Root · 2 generations backK875128 Trans/R Needle GuideCIVCO Medical Instruments Co., Inc. · 1988
  2. 1 generation backK970514 Disposable Transrectal/Transvaginal/Endocavity Ultrasound Needle…CIVCO Medical Instruments Co., Inc. · 1997 · Recalled
  3. This deviceK223689 Disposable Needle Guides and GridsAdvance Medical Designs, Inc. · 2023
  4. Descendant · cites it directly · 0 of its ownK260161 SmartGuide Disposable Guides and GridsUC-CARE, Ltd. · 2026

Most influential descendants

Showing 1 of 1 · See all
  • K260161SmartGuide Disposable Guides and GridsUC-CARE, Ltd. · 2026 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−2K875128Trans/R Needle GuideCIVCO Medical Instruments Co., Inc.1988—
−1K970514Disposable Transrectal/Transvaginal/Endocavity Ultrasound Needle Instrument…CIVCO Medical Instruments Co., Inc.19973
0 (this device)K223689Disposable Needle Guides and GridsAdvance Medical Designs, Inc.2023—
+1K260161SmartGuide Disposable Guides and GridsUC-CARE, Ltd.2026—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198810

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202610
FIG. 1 — Lineage of K223689, 1988–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in ITX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new ITX device

  1. #1 K260114 Align® Cover and Pad Guidance Toolscore 13.6 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K970514Disposable Transrectal/Transvaginal/Endocavity Ultrasound Needle Instrument Guide
Our reading of the summary gave K972514, FDA’s number for Laserex LP1532 Photocoagulator (Ellex Medical Pty, Ltd.). Corrected to the number one digit away whose FDA name carries the summary’s words for the device, “Disposable Endocavity Needle / Biopsy Guide”.
CIVCO Medical Instruments Co., Inc.19973
†K180970Disposable guides KDNG00Koelis2018—
†K222052VitroPROCIVCO Medical Instruments Co., Inc.2022—
†K141334Reusable GuideKoelis2014—

Also cleared against K970514: 3 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K260161SmartGuide Disposable Guides and GridsUC-CARE, Ltd.20260

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 35 years and passes through 2 companies; a new generation was cleared every 26.1 years on median.
  • 1 of the 3 ancestors has a recall of any class.
  • Of its descendants, K260161 (UC-CARE, Ltd., 2026) has gone furthest, with 0 descendants of its own.
  • 3 other devices also cite its predicate K970514.

How does its category compare?

All ITX devices

ITX Transducer, Ultrasonic, Diagnostic: FDA decisions, review times, recalls and adverse event reports over 20 years. 2023, this device’s year, is highlighted.

FDA decisions per year · ITX

4in 2025

2007: 102008: 122009: 172010: 102011: 102012: 72013: 32014: 42015: 12016: 42017: 62018: 22019: 12020: 32021: 32022: 22023: 62024: 32025: 42026 (partial year): 6
2007high 17 (2009) · low 1 (2015)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · ITX

126in 2025

2007: 26 days median2008: 73 days median2009: 28 days median2010: 42 days median2011: 16 days median2012: 25 days median2013: 105 days median2014: 41 days median2016: 151 days median2017: 110 days median2020: 120 days median2021: 139 days median2023: 213 days median2024: 81 days median2025: 126 days median2026 (partial year): 158 days median
2007high 213 (2023) · low 16 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · ITX

2in 2025

2008: 42009: 42010: 42011: 12012: 12014: 12015: 52017: 12018: 152020: 32021: 10, 10 Class I2022: 62023: 12024: 12025: 2
2007high 15 (2018) · low 0 (2007)2026

Class I (10 since 2007) Class II/III not classified

Adverse event reports per year · ITX

571in 2025

2007: 162008: 392009: 232010: 302011: 342012: 292013: 382014: 432015: 1832016: 2692017: 4122018: 1302019: 1192020: 1162021: 1462022: 872023: 1382024: 9882025: 571
2007high 988 (2024) · low 16 (2007)2025

MAUDE reports naming product code ITX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071026016
20081273439
20091728423
20101042430
20111016134
2012725129
20133105038
2014441143
20151—5183
201641510269
201761101412
20182—15130
20191—0119
202031203116
2021313910 (10)146
20222—687
202362131138
20243811988
202541262571
202661580—

What is it indicated for?

"Disposable Needle Guides and Grids are used to assist and aid physicians in performing an endocavity diagnosis ultrasound needle guided procedure using guided intervention by providing fixed guiding for the precise insertion of linear instruments, such as needles. The Needle Guides and Grids are designed to aid adult patient population, in need of a biopsy of an internal organ, or internal delivery or removal of fluid within the body cavity, via the use of a needle, during an ultrasound procedure by retaining the needle tip and barrel within the ultrasound beam."

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K223689: Disposable Needle Guides and Grids.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K223689

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026