510(k) · Cleared
ClearedArise™ UHP Dilatation Catheter
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Creagh Medical, Ltd. · LIT Catheter, Angioplasty, Peripheral, Transluminal
Cleared on Mar 22, 2023 as substantially equivalent to K102645 (Creagh Medical, Ltd., 2010) after a 57-day review. Its family tree reaches back 4 generations to 2004.
- Decided
- Mar 22, 2023
- Review
- 57 days
- Class
- Class II
- Product code
- LIT
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 4 generations to K042537 (2004). 9 ancestors in all, the oldest K014212 (2002). No later device cites it as a predicate yet.
- Root · 4 generations backK042537 Submarine Plus Percutaneous Transluminal Angioplasty (Pta) Catheter…Invatec Innovative Technologies · 2004
- 3 generations backK072947 Savvy Long and Sleek Peripheral Transluminal Angioplasty (Pta)…ClearStream Technologies, Ltd. · 2008
- 2 generations backK083919 Amphirion Deep 0.014 Otw Pta Balloon CatheterInvatec Innovative Technologies, S.R.L. · 2009 · Recalled
- 1 generation backK102645 Willow/Elm Pta Balloon Dilatation CatheterCreagh Medical, Ltd. · 2010
- This deviceK230191 Arise™ UHP Dilatation CatheterCreagh Medical, Ltd. · 2023
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −4 | K042537 | Submarine Plus Percutaneous Transluminal Angioplasty (Pta) Catheter, Model… | Invatec Innovative Technologies | 2004 | — |
| −3 | K072947 | Savvy Long and Sleek Peripheral Transluminal Angioplasty (Pta) Catheters | ClearStream Technologies, Ltd. | 2008 | — |
| −2 | K083919 | Amphirion Deep 0.014 Otw Pta Balloon Catheter | Invatec Innovative Technologies, S.R.L. | 2009 | 1 |
| −1 | K102645 | Willow/Elm Pta Balloon Dilatation Catheter | Creagh Medical, Ltd. | 2010 | — |
| 0 (this device) | K230191 | Arise™ UHP Dilatation Catheter | Creagh Medical, Ltd. | 2023 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 2002 | 1 | 0 |
| 2005 | 3 | 0 |
| 2008 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in LIT? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new LIT device
- #1 K241040 Amethyst HP PTA OTW 0.035 Catheterscore 13.9 · 9 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K102645 | Willow/Elm Pta Balloon Dilatation CatheterSummary page 4…sification: Product Code: LIT Predicate Device: ELM High Pressure Balloon Dilatation Catheter 510(k)#: K102645 Device Description The Surmodics™ Arise™ UHP Dilatation Catheter is a coaxial Over the Wire (OTW) 0.035” PTA Balloon Dilatation… | 2010 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 19 years and passes through 4 companies; a new generation was cleared every 3.2 years on median.
- 5 of the 9 ancestors have a recall of any class.
- 3 other devices also cite its predicate K102645.
How does its category compare?
All LIT devicesLIT Catheter, Angioplasty, Peripheral, Transluminal: FDA decisions, review times, recalls and adverse event reports over 20 years. 2023, this device’s year, is highlighted.
FDA decisions per year · LIT
3in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · LIT
90in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · LIT
1in 2025
Class I (2 since 2007) Class II/III not classified
Adverse event reports per year · LIT
2,073in 2025
MAUDE reports naming product code LIT, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 6 | 64 | 0 | 577 |
| 2008 | 8 | 53 | 0 | 513 |
| 2009 | 7 | 29 | 2 | 623 |
| 2010 | 13 | 78 | 1 | 809 |
| 2011 | 10 | 82 | 0 | 857 |
| 2012 | 19 | 29 | 0 | 1,277 |
| 2013 | 14 | 79 | 2 (2) | 1,242 |
| 2014 | 12 | 90 | 3 | 1,178 |
| 2015 | 19 | 112 | 0 | 1,279 |
| 2016 | 11 | 116 | 1 | 1,529 |
| 2017 | 9 | 57 | 0 | 2,081 |
| 2018 | 6 | 118 | 2 | 2,188 |
| 2019 | 4 | 40 | 3 | 2,405 |
| 2020 | 9 | 125 | 0 | 2,443 |
| 2021 | 4 | 61 | 1 | 2,492 |
| 2022 | 8 | 122 | 0 | 2,155 |
| 2023 | 6 | 167 | 0 | 1,807 |
| 2024 | 6 | 43 | 2 | 1,913 |
| 2025 | 3 | 90 | 1 | 2,073 |
| 2026 | 4 | 205 | 0 | — |
What is it indicated for?
The UHP Dilatation Catheter is indicated for use in Percutaneous Transluminal Angioplasty of the femoral, iliac and renal arteries, and for the treatment of obstructive lesions of native or synthetic arteriovenous dialysis fistulae.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K230191 · printed Nov 4, 2026
Cite this page
510(k) Report. “K230191: Arise™ UHP Dilatation Catheter.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K230191
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026