510(k) Report

510(k) · Cleared

Cleared

Saranas Early Bird Bleed Monitoring System

K230273510(k) TraditionalCleared May 25, 2023114-day reviewClass II21 CFR 870.1345

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Saranas, Inc. · QFJ Intravascular Bleed Monitor

Cleared on May 25, 2023 as substantially equivalent to DEN180021 (Saranas, Inc., 2019) after a 114-day review. Its family tree reaches back 1 generation to 2019.

Decided
May 25, 2023
Review
114 days
Class
Class II
Product code
QFJ
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to DEN180021 (2019). No later device cites it as a predicate yet.

DEN180021 · Early Bird Bleed Monitoring System · Saranas, Inc. · 201920162018202020222024
DEN180021 · Early Bird Bleed Monitoring System · Saranas, Inc. · 20190
  1. Root · 1 generation backDEN180021 Early Bird Bleed Monitoring SystemSaranas, Inc. · 2019
  2. This deviceK230273 Saranas Early Bird Bleed Monitoring SystemSaranas, Inc. · 2023
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1DEN180021Early Bird Bleed Monitoring SystemSaranas, Inc.2019—
0 (this device)K230273Saranas Early Bird Bleed Monitoring SystemSaranas, Inc.2023—
FIG. 1 — Lineage of K230273, 2019–2023Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in QFJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

  • Candidate predicates for a device like this, rankedin the report
  • Recall history across each candidate’s familyin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*DEN180021Early Bird Bleed Monitoring System
Summary page 4
…lence Traditional 510(k) claiming equivalence to legally marketed device of same name: Saranas® Early Bird® Bleed Monitoring System DE NOVO Submission Number: DEN180021 Date DE NOVO Classification Granted: March 1, 2019 Device Description The Saranas Early Bird Bleed Monitoring System…
Saranas, Inc.2019—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.

How does its category compare?

All QFJ devices

QFJ Intravascular Bleed Monitor: FDA decisions, review times, recalls and adverse event reports over 20 years. 2023, this device’s year, is highlighted.

FDA decisions per year · QFJ

1in 2023

2019: 12023: 1
2007high 1 (2019) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · QFJ

Too few QFJ 510(k)s in any year since 2007 to give a median.

Recalls per year · QFJ

No recall names QFJ since 2007.

Adverse event reports per year · QFJ

3in 2023

2023: 3
2007high 3 (2023) · low 0 (2007)2025

MAUDE reports naming product code QFJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20180—00
20191—00
20200—00
20210—00
20220—00
20231—03
20240—00
20250—00
20260—0—

What is it indicated for?

The Early Bird is indicated for the introduction of catheters, catheter balloons, and other diagnostic and interventional devices into the femoral artery or femoral vein while maintaining hemostasis during diagnostic and interventional endovascular procedures.

The Early Bird provides physicians with an early indication of a potential internal bleeding complication by initial detection and monitoring of extravascular fluid accumulation.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K230273: Saranas Early Bird Bleed Monitoring System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K230273

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026