510(k) Report

510(k) · Cleared

Cleared

SafeLan® (2 models/SafeLan 26G, SafeLan 30G), SafeLan®-Pro (1 model/SafeLan®-Pro)

K230759510(k) TraditionalCleared Jun 13, 202385-day reviewClass II21 CFR 878.4850

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Bosungmeditech Co., Ltd. · QRK Single Use Only Blood Lancet Without An Integral Sharps Injury Prevention Feature

Cleared on Jun 13, 2023 after an 85-day review. The summary cites one number, which could not be confirmed as its predicate (see the table below).

Decided
Jun 13, 2023
Review
85 days
Class
Class II
Product code
QRK
Recalls
None
Predicates
1

The summary cites one number, which could not be confirmed as its predicate (see the table below).

FIG. 1 — Lineage of K230759Source: FDA 510(k) database · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in QRK? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new QRK device

  1. #1 K221507 Disposable Blood Lancetscore 16.5 · 3 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary; numbers the summary cites that cannot be its predicate are marked – and kept off the family tree.

TypeNumberDeviceApplicantDecidedRecalls
Kept off the family treeK042422FDA’s K042422 is D3 Chroma
Not matched in our reading of the summary (scans can blur digits), so it is kept off the family tree
Sybron Dental Specialties, Inc.2004—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

How does its category compare?

All QRK devices

QRK Single Use Only Blood Lancet Without An Integral Sharps Injury Prevention Feature: FDA decisions, review times, recalls and adverse event reports over 20 years. 2023, this device’s year, is highlighted.

FDA decisions per year · QRK

2in 2025

2022: 32023: 72024: 32025: 22026 (partial year): 2
2007high 7 (2023) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · QRK

55in 2024

2022: 100 days median2023: 89 days median2024: 55 days median
2007high 100 (2022) · low 55 (2024)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · QRK

No recall names QRK since 2007.

Adverse event reports per year · QRK

9in 2025

2022: 22023: 122024: 102025: 9
2007high 12 (2023) · low 0 (2007)2025

MAUDE reports naming product code QRK, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20180—00
20190—00
20200—00
20210—00
2022310002
2023789012
2024355010
20252—09
20262—0—

What is it indicated for?

SafeLan® is sterile, single use device that has been designed for single patient use by lay users in a home. Their intended use is for performing skin punctures on patients for the purpose of obtaining capillary blood samples.

SafeLan®-Pro: Use with SafeLan® for capillary blood sampling and the SafeLan®-Pro as the multiple use execution device which the SafeLan® lancet attaches.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K230759: SafeLan® (2 models/SafeLan 26G, SafeLan 30G), SafeLan®-Pro (1 model/SafeLan®-Pro).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K230759

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Page last updated Nov 3, 2026