510(k) Report

510(k) · Cleared

Cleared

TENS device-HeadaTerm 2 (Model: YF-HT2)

K230782510(k) TraditionalCleared Feb 26, 2024341-day reviewClass II21 CFR 882.5891

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Wat Medical Technology, Inc. · PCC Stimulator, Nerve, Electrical, Transcutaneous, For Migraine

Cleared on Feb 26, 2024 as substantially equivalent to K172450 (Wat Medical Technology (Ningbo) Co., Ltd., 2018) and 1 other predicate after a 341-day review. Its family tree reaches back 5 generations to 2014.

Decided
Feb 26, 2024
Review
341 days
Class
Class II
Product code
PCC
Recalls
None
Predicates
2

Its longest line of descent runs back 5 generations to DEN120019 (2014). 6 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 5 generations backDEN120019 CefalyStx-Med Sprl · 2014
  2. 4 generations backK160237 CefalyCefaly Technology · 2016
  3. 3 generations backK171446 Cefaly AcuteCefaly Technology · 2017
  4. 2 generations backK173006 Cefaly DualCefaly Technology · 2017
  5. 1 generation backK201895 Cefaly DualCefaly Technology · 2020
  6. This deviceK230782 TENS device-HeadaTerm 2 (Model: YF-HT2)Wat Medical Technology, Inc. · 2024
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5DEN120019CefalyStx-Med Sprl2014—
−4K160237CefalyCefaly Technology2016—
−3K171446Cefaly AcuteCefaly Technology2017—
−2K173006Cefaly DualCefaly Technology2017—
−1K201895Cefaly DualCefaly Technology2020—
0 (this device)K230782TENS device-HeadaTerm 2 (Model: YF-HT2)Wat Medical Technology, Inc.2024—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
201810
FIG. 1 — Lineage of K230782, 2014–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in PCC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new PCC device

  1. #1 K201895 Cefaly Dualscore 16.0 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K172450TENS device-HeadaTerm, eEspress
Summary page 4
…Class II Panel: Neurology Product Code: PCC 3. Predicate Device Primary predicate device: 510(K) number: K172450 Device Name: TENS device-HeadaTerm, eEspresso Manufacturer: WAT Medical Technology Inc. Comm…
Wat Medical Technology (Ningbo) Co., Ltd.2018—
*K201895Cefaly Dual
Summary page 5
…Code: PCC 510(k) Summary - 1 of 7 Secondary predicate device: 510(K) number: K201895 Device Name: Cefaly® Dual Manufacturer: CEFALY Technology Common name Stimu…
Cefaly Technology2020—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 10 years and passes through 3 companies; a new generation was cleared every 2.0 years on median.
  • None of the 6 ancestors has a recall.

How does its category compare?

All PCC devices

PCC Stimulator, Nerve, Electrical, Transcutaneous, For Migraine: FDA decisions, review times, recalls and adverse event reports over 20 years. 2024, this device’s year, is highlighted.

FDA decisions per year · PCC

5in 2024

2014: 12016: 12017: 22018: 12019: 12020: 12021: 42022: 12024: 52026 (partial year): 1
2007high 5 (2024) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · PCC

211in 2024

2021: 88 days median2024: 211 days median
2007high 211 (2024) · low 88 (2021)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · PCC

No recall names PCC since 2007.

Adverse event reports per year · PCC

2in 2025

2014: 22016: 22017: 22019: 22020: 12021: 72023: 22024: 62025: 2
2007high 7 (2021) · low 0 (2007)2025

MAUDE reports naming product code PCC, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20141—02
20150—00
20161—02
20172—02
20181—00
20191—02
20201—01
202148807
20221—00
20230—02
2024521106
20250—02
20261—0—

What is it indicated for?

The TENS device-HeadaTerm 2 is indicated for the prophylactic treatment of episodic migraine in patients 18 years of age or older.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K230782: TENS device-HeadaTerm 2 (Model: YF-HT2).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K230782

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026