510(k) Report

510(k) · Cleared

Cleared

Mix2Vial® Transfer Device

K231071510(k) TraditionalCleared Jan 19, 2024280-day reviewClass II21 CFR 880.5440

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

West Pharma. Services IL, Ltd. · LHI Set, I.V. Fluid Transfer

Cleared on Jan 19, 2024 as substantially equivalent to K031861 (Medimop Medical Projects, Ltd., 2003) after a 280-day review. Its family tree reaches back 1 generation to 2003.

Decided
Jan 19, 2024
Review
280 days
Class
Class II
Product code
LHI
Recalls
None
Predicates
1

Its longest line of descent runs back 1 generation to K031861 (2003). No later device cites it as a predicate yet.

K031861 · MIX2VIAL Transfer Device · Medimop Medical Projects, Ltd. · 2003200020052010201520202025
  1. Root · 1 generation backK031861 MIX2VIAL Transfer DeviceMedimop Medical Projects, Ltd. · 2003
  2. This deviceK231071 Mix2Vial® Transfer DeviceWest Pharma. Services IL, Ltd. · 2024
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−1K031861MIX2VIAL Transfer DeviceMedimop Medical Projects, Ltd.2003—
0 (this device)K231071Mix2Vial® Transfer DeviceWest Pharma. Services IL, Ltd.2024—
FIG. 1 — Lineage of K231071, 2003–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in LHI? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new LHI device

  1. #1 K252987 ADRx™ Admixture Devicescore 12.4 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K031861MIX2VIAL Transfer Device
Summary page 4
…ar Administration Set Product Code: LHI Regulation No.: 880.5440 Class: II Panel Identification: General Hospital Panel Predicate Device: Mix2vial Transfer Device – K031861 Page 1 of 10 Mix2Vial® Transfer Device…
Medimop Medical Projects, Ltd.2003—

Also cleared against K031861: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • Its one ancestor has no recall.
  • 2 other devices also cite its predicate K031861.

How does its category compare?

All LHI devices

LHI Set, I.V. Fluid Transfer: FDA decisions, review times, recalls and adverse event reports over 20 years. 2024, this device’s year, is highlighted.

FDA decisions per year · LHI

6in 2025

2007: 32008: 42009: 82010: 52011: 32012: 52013: 42014: 62015: 32016: 32017: 52018: 12019: 42020: 32021: 32022: 62023: 52024: 92025: 62026 (partial year): 2
2007high 9 (2024) · low 1 (2018)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · LHI

196in 2025

2007: 89 days median2008: 154 days median2009: 95 days median2010: 139 days median2011: 99 days median2012: 127 days median2013: 102 days median2014: 63 days median2015: 99 days median2016: 159 days median2017: 56 days median2019: 247 days median2020: 189 days median2021: 396 days median2022: 278 days median2023: 90 days median2024: 166 days median2025: 196 days median
2007high 396 (2021) · low 56 (2017)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · LHI

1in 2024

2007: 12008: 32009: 12010: 32011: 122013: 32016: 1, 1 Class I2017: 12018: 3, 3 Class I2019: 12022: 22023: 2, 2 Class I2024: 12026 (partial year): 1
2007high 12 (2011) · low 0 (2012)2026

Class I (6 since 2007) Class II/III not classified

Adverse event reports per year · LHI

1,334in 2025

2007: 182008: 272009: 372010: 492011: 1552012: 5292013: 1542014: 1552015: 1282016: 2192017: 5362018: 1,4992019: 1,6342020: 1,1712021: 9332022: 1,8342023: 1,0472024: 1,2702025: 1,334
2007high 1,834 (2022) · low 18 (2007)2025

MAUDE reports naming product code LHI, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
2007389118
20084154327
2009895137
20105139349
201139912155
201251270529
201341023154
20146630155
20153990128
201631591 (1)219
20175561536
20181—3 (3)1,499
2019424711,634
2020318901,171
202133960933
2022627821,834
20235902 (2)1,047
2024916611,270
2025619601,334
20262—1—

What is it indicated for?

The Mix2Vial® Transfer Device is intended for transferring drugs contained in two vials.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K231071: Mix2Vial® Transfer Device.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 4, 2026. https://510kreport.com/device/K231071

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026