ViewFlex™ Eco Reprocessed ICE Catheter

K231588510(k) SpecialCleared Jun 30, 202329-day reviewClass II21 CFR 870.1200

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Abbott Medical · OWQ Reprocessed Intravascular Ultrasound Catheter

Cleared on Jun 30, 2023 as substantially equivalent to K230934 (Abbott Medical, 2023) after a 29-day review. Its family tree reaches back 5 generations to 2010. 3 later devices descend from it.

Decided
Jun 30, 2023
Review
29 days
Class
Class II
Product code
OWQ
Recalls
None
Predicates
1

Its longest line of descent runs back 5 generations to K101239 (2010). 6 ancestors in all, the oldest K071234 (2007). 3 later devices descend from it, 1 citing it directly.

  1. Root · 5 generations backK101239 Viewflex Plus Ice CatheterSt Jude Medical · 2010
  2. 4 generations backK121381 Viewflex Xtra Ice CatheterSt Jude Medical · 2012
  3. 3 generations backK133853 Viewflex Xtra Ice CatheterIrvine Biomedical, Inc., A St. Jude Medical Company · 2014
  4. 2 generations backK222217 ViewFlex Xtra Reprocessed ICE CatheterAbbott Medical · 2022
  5. 1 generation backK230934 ViewFlex™ Eco Reprocessed ICE CatheterAbbott Medical · 2023
  6. This deviceK231588 ViewFlex™ Eco Reprocessed ICE CatheterAbbott Medical · 2023
  7. Descendant · cites it directly · 2 of its ownK251211 ViewFlex™ Xtra ICE Catheter; ViewFlex™ Eco Reprocessed ICE Catheter…Abbott Medical · 2025
  8. Descendant · 2 generations on · 0 of its ownK250305 Reprocessed Agilis NxT Steerable IntroducerInnovative Health · 2026
  9. Descendant · 2 generations on · 0 of its ownK250314 Medline ReNewal Reprocessed Abbott Agilis Nxt Steerable IntroducerSurgical Instrument Service and Savings, Inc. · 2025

Most influential descendants

Showing 3 of 3 · See all
  • K251211ViewFlex™ Xtra ICE Catheter; ViewFlex™ Eco Reprocessed ICE Catheter; Advisor™ HD Grid…Abbott Medical · 2025 · cites it directly2descendants
  • K250305Reprocessed Agilis NxT Steerable IntroducerInnovative Health · 2026 · 2 generations on0descendants
  • K250314Medline ReNewal Reprocessed Abbott Agilis Nxt Steerable IntroducerSurgical Instrument Service and Savings, Inc. · 2025 · 2 generations on0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−5K101239Viewflex Plus Ice CatheterSt Jude Medical2010—
−4K121381Viewflex Xtra Ice CatheterSt Jude Medical2012—
−3K133853Viewflex Xtra Ice CatheterIrvine Biomedical, Inc., A St. Jude Medical Company2014—
−2K222217ViewFlex Xtra Reprocessed ICE CatheterAbbott Medical2022—
−1K230934ViewFlex™ Eco Reprocessed ICE CatheterAbbott Medical2023—
0 (this device)K231588ViewFlex™ Eco Reprocessed ICE CatheterAbbott Medical2023—
+1K251211ViewFlex™ Xtra ICE Catheter; ViewFlex™ Eco Reprocessed ICE Catheter; Advisor™…Abbott Medical2025—
+2K250305Reprocessed Agilis NxT Steerable IntroducerInnovative Health2026—
+2K250314Medline ReNewal Reprocessed Abbott Agilis Nxt Steerable IntroducerSurgical Instrument Service and Savings, Inc.2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200710

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202520
202610
FIG. 1 — Lineage of K231588, 2010–2026Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in OWQ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new OWQ device

  1. #1 K254149 Reprocessed AcuNav CRYSTAL™ Ultrasound…score 13.4 · 7 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K230934ViewFlex™ Eco Reprocessed ICE Catheter
Summary page 5
…ascular Catheter Product Code OWQ Subsequent Product Code OBJ Predicate Device ViewFlex™ Eco Reprocessed ICE Catheter (K230934) Device Description The ViewFlex™ Eco Reprocessed ICE Catheter is a temporary…
Abbott Medical2023—

What descends from it? (3)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K251211ViewFlex™ Xtra ICE Catheter; ViewFlex™ Eco Reprocessed ICE Catheter; Advisor™ HD Grid…Abbott Medical20252

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 13 years and passes through 3 companies; a new generation was cleared every 1.9 years on median.
  • 1 of the 6 ancestors has a recall of any class.
  • Of its descendants, K251211 (Abbott Medical, 2025) has gone furthest, with 2 descendants of its own.

How does its category compare?

All OWQ devices

OWQ Reprocessed Intravascular Ultrasound Catheter: FDA decisions, review times, recalls and adverse event reports over 20 years. 2023, this device’s year, is highlighted.

FDA decisions per year · OWQ

3in 2025

2007: 12009: 12011: 12012: 12016: 22017: 22018: 12019: 32020: 12022: 22023: 82024: 12025: 32026 (partial year): 1
2007high 8 (2023) · low 0 (2008)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · OWQ

100in 2025

2019: 261 days median2023: 78 days median2025: 100 days median
2007high 261 (2019) · low 78 (2023)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · OWQ

2in 2025

2014: 12025: 2
2007high 2 (2025) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · OWQ

42in 2025

2013: 42014: 22015: 62016: 52017: 22018: 22019: 92020: 292021: 382022: 242023: 292024: 372025: 42
2007high 42 (2025) · low 0 (2007)2025

MAUDE reports naming product code OWQ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071—00
20080—00
20091—00
20100—00
20111—00
20121—00
20130—04
20140—12
20150—06
20162—05
20172—02
20181—02
2019326109
20201—029
20210—038
20222—024
2023878029
20241—037
20253100242
20261—0—

What is it indicated for?

The ViewFlex™ Eco Reprocessed ICE Catheter is indicated for use in adult and adolescent pediatric patients to visualize cardiac structures, blood flow and other devices within the heart.

Indications for use read by OCR from a scanned FDA summary, so letters may be misread. Check the PDF before quoting it.

Cite this page

510(k) Report. “K231588: ViewFlex™ Eco Reprocessed ICE Catheter.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K231588

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026