510(k) Report

510(k) · Cleared

Cleared

Endoscopic Ultrasonic Probe (P2612S-L); Endoscopic Ultrasonic Probe (P2620S-L)

K231666510(k) TraditionalCleared Dec 13, 2023189-day reviewClass II21 CFR 892.1570

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

FUJIFILM Healthcare Americas Corporation · ITX Transducer, Ultrasonic, Diagnostic

Cleared on Dec 13, 2023 as substantially equivalent to K994103 (Olympus America, Inc., 2000) after a 189-day review. Its family tree reaches back 4 generations to 1993. 2 later devices descend from it.

Decided
Dec 13, 2023
Review
189 days
Class
Class II
Product code
ITX
Recalls
None
Predicates
1

Its longest line of descent runs back 4 generations to K926514 (1993). 7 ancestors in all, the oldest K882061 (1988). 2 later devices descend from it, 2 citing it directly.

  1. Root · 4 generations backK926514 Endoscopic Ultrasound System Type 20Olympus Corp. · 1993 · Recalled
  2. 3 generations backK951994 Olympus EU-M30 Endoscopic Ultrasound CenterOlympus America, Inc. · 1996
  3. 2 generations backK982610 Olympus UM-2R/3R Ultrasonic Probes and Associated Ancillary…Olympus Optical, Co. · 1998
  4. 1 generation backK994103 Olympus UM-S30-25R Ultrasonic Probe and Associated Ancillary…Olympus America, Inc. · 2000
  5. This deviceK231666 Endoscopic Ultrasonic Probe (P2612S-L); Endoscopic Ultrasonic Probe…FUJIFILM Healthcare Americas Corporation · 2023
  6. Descendant · cites it directly · 0 of its ownK250883 Ultrasonic Probe UM-3R (UM-3R); Ultrasonic Probe UM-G20-29R…Olympus Medical Systems Corporation · 2025
  7. Descendant · cites it directly · 0 of its ownK250762 Ultrasonic Probe UM-S20-17S (UM-S20-17S); Ultrasonic Probe…Olympus Medical Systems Corporation · 2025

Most influential descendants

Showing 2 of 2 · See all
  • K250883Ultrasonic Probe UM-3R (UM-3R); Ultrasonic Probe UM-G20-29R (UM-G20-29R)Olympus Medical Systems Corporation · 2025 · cites it directly0descendants
  • K250762Ultrasonic Probe UM-S20-17S (UM-S20-17S); Ultrasonic Probe UM-S20-20R (UM-S20-20R)Olympus Medical Systems Corporation · 2025 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K926514Endoscopic Ultrasound System Type 20Olympus Corp.19931
−3K951994Olympus EU-M30 Endoscopic Ultrasound CenterOlympus America, Inc.1996—
−2K982610Olympus UM-2R/3R Ultrasonic Probes and Associated Ancillary Equipment (Urinary…Olympus Optical, Co.1998—
−1K994103Olympus UM-S30-25R Ultrasonic Probe and Associated Ancillary Equipment for…Olympus America, Inc.2000—
0 (this device)K231666Endoscopic Ultrasonic Probe (P2612S-L); Endoscopic Ultrasonic Probe (P2620S-L)FUJIFILM Healthcare Americas Corporation2023—
+1K250883Ultrasonic Probe UM-3R (UM-3R); Ultrasonic Probe UM-G20-29R (UM-G20-29R)Olympus Medical Systems Corporation2025—
+1K250762Ultrasonic Probe UM-S20-17S (UM-S20-17S); Ultrasonic Probe UM-S20-20R…Olympus Medical Systems Corporation2025—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
198810
199510
199810

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202520
FIG. 1 — Lineage of K231666, 1993–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in ITX? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new ITX device

  1. #1 K260114 Align® Cover and Pad Guidance Toolscore 13.6 · 6 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K994103Olympus UM-S30-25R Ultrasonic Probe and Associated Ancillary Equipment for…
Summary page 4
…Review Panel Predicate Device: • OLYMPUS UM-S30-25R ULTRASONIC PROBE AND ASSOCIATED ANCILLARY EQUIPMENT FOR GASTROINTESTINAL TRACT (K994103) Reference Device: • Modifications to EUB-525 Diagnostic Ultrasound Scanner; EUB-2000 Diagnostic Ultrasound Scanner;…
Olympus America, Inc.2000—
†K012239Modifications to Eub-525 Diagnostic Ultrasound Scanner; Eub-2000 Diagnostic Ultrasound…Hitachi Medical Corp.2001—

What descends from it? (2)

2 later devices cite it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K250883Ultrasonic Probe UM-3R (UM-3R); Ultrasonic Probe UM-G20-29R (UM-G20-29R)Olympus Medical Systems Corporation20250
K250762Ultrasonic Probe UM-S20-17S (UM-S20-17S); Ultrasonic Probe UM-S20-20R (UM-S20-20R)Olympus Medical Systems Corporation20250

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 30 years and passes through 4 companies; a new generation was cleared every 2.7 years on median.
  • 1 of the 7 ancestors has a recall of any class.
  • Of its descendants, K250883 (Olympus Medical Systems Corporation, 2025) has gone furthest, with 0 descendants of its own.

How does its category compare?

All ITX devices

ITX Transducer, Ultrasonic, Diagnostic: FDA decisions, review times, recalls and adverse event reports over 20 years. 2023, this device’s year, is highlighted.

FDA decisions per year · ITX

4in 2025

2007: 102008: 122009: 172010: 102011: 102012: 72013: 32014: 42015: 12016: 42017: 62018: 22019: 12020: 32021: 32022: 22023: 62024: 32025: 42026 (partial year): 6
2007high 17 (2009) · low 1 (2015)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · ITX

126in 2025

2007: 26 days median2008: 73 days median2009: 28 days median2010: 42 days median2011: 16 days median2012: 25 days median2013: 105 days median2014: 41 days median2016: 151 days median2017: 110 days median2020: 120 days median2021: 139 days median2023: 213 days median2024: 81 days median2025: 126 days median2026 (partial year): 158 days median
2007high 213 (2023) · low 16 (2011)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · ITX

2in 2025

2008: 42009: 42010: 42011: 12012: 12014: 12015: 52017: 12018: 152020: 32021: 10, 10 Class I2022: 62023: 12024: 12025: 2
2007high 15 (2018) · low 0 (2007)2026

Class I (10 since 2007) Class II/III not classified

Adverse event reports per year · ITX

571in 2025

2007: 162008: 392009: 232010: 302011: 342012: 292013: 382014: 432015: 1832016: 2692017: 4122018: 1302019: 1192020: 1162021: 1462022: 872023: 1382024: 9882025: 571
2007high 988 (2024) · low 16 (2007)2025

MAUDE reports naming product code ITX, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20071026016
20081273439
20091728423
20101042430
20111016134
2012725129
20133105038
2014441143
20151—5183
201641510269
201761101412
20182—15130
20191—0119
202031203116
2021313910 (10)146
20222—687
202362131138
20243811988
202541262571
202661580—

What is it indicated for?

This product is a medical ultrasonic probe. It is intended for the observation and diagnosis of the gastrointestinal tract and surrounding organs under the management of physicians at medical facilities. This product is intended for adults.

Modes of Operation: B-mode

Never use this product for any other purposes.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K231666: Endoscopic Ultrasonic Probe (P2612S-L); Endoscopic Ultrasonic Probe (P2620S-L).” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K231666

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026