510(k) · Cleared
ClearedQuick - Radius Disposable Set
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
GM Dos Reis Industria e Comercio Ltda. · HRS Plate, Fixation, Bone
Cleared on Jan 12, 2024 as substantially equivalent to K182718 (Gm Dos Reis Industria E Comerico Ltda., 2019) after a 217-day review. Its family tree reaches back 11 generations to 1996.
- Decided
- Jan 12, 2024
- Review
- 217 days
- Class
- Class II
- Product code
- HRS
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 11 generations to K962616 (1996). 134 ancestors in all, the oldest K792022 (1979). No later device cites it as a predicate yet.
- Root · 11 generations backK962616 Synthes Dorsal Distal Radius Plate (DDRP) SystemSynthes (Usa) · 1996
- 7 generations between
- 3 generations backK090675 Smith & Nephew, Inc. VLP Foot Plating, Screw System and AccessoriesSmith & Nephew, Inc. · 2009
- 2 generations backK100776 Synthes 2.4 MM/2.7 MM Variable Angle LCP Forefoot/Midfoot SystemSynthes (Usa) · 2010
- 1 generation backK182718 Mini and Micro Fragments Reconstruction System – GMReisGm Dos Reis Industria E Comerico Ltda. · 2019
- This deviceK231684 Quick - Radius Disposable SetGM Dos Reis Industria e Comercio Ltda. · 2024
Show all 11 generations
- Root · 11 generations backK962616 Synthes Dorsal Distal Radius Plate (DDRP) SystemSynthes (Usa) · 1996
- 10 generations backK982732 Synthes (Usa) Distal Radius Plate System (DRPS)Synthes · 1998
- 9 generations backK023007 Distal Radius Fracture Repair SystemHand Innovations, Inc. · 2002
- 8 generations backK030198 Hand Innovations, Inc. Distal Radius Fracture Repair SystemHand Innovations, Inc. · 2003
- 7 generations backK032705 Distal Radius Fracture Repair SystemHand Innovations, Inc. · 2003
- 6 generations backK050932 Distal Volar Radius Anatomical Plate SystemHand Innovations, Inc. · 2005 · Recalled
- 5 generations backK051735 Peri-Loc Locking Bone Plates and Locking Bone Screws for the Upper…Smith & Nephew, Inc. · 2005
- 4 generations backK071563 Peri-Loc Periarticular Locked Plating SystemSmith & Nephew, Inc. · 2007
- 3 generations backK090675 Smith & Nephew, Inc. VLP Foot Plating, Screw System and AccessoriesSmith & Nephew, Inc. · 2009
- 2 generations backK100776 Synthes 2.4 MM/2.7 MM Variable Angle LCP Forefoot/Midfoot SystemSynthes (Usa) · 2010
- 1 generation backK182718 Mini and Micro Fragments Reconstruction System – GMReisGm Dos Reis Industria E Comerico Ltda. · 2019
- This deviceK231684 Quick - Radius Disposable SetGM Dos Reis Industria e Comercio Ltda. · 2024
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −11 | K962616 | Synthes Dorsal Distal Radius Plate (DDRP) System | Synthes (Usa) | 1996 | — |
| −10 | K982732 | Synthes (Usa) Distal Radius Plate System (DRPS) | Synthes | 1998 | — |
| −9 | K023007 | Distal Radius Fracture Repair System | Hand Innovations, Inc. | 2002 | — |
| −8 | K030198 | Hand Innovations, Inc. Distal Radius Fracture Repair System | Hand Innovations, Inc. | 2003 | — |
| −7 | K032705 | Distal Radius Fracture Repair System | Hand Innovations, Inc. | 2003 | — |
| −6 | K050932 | Distal Volar Radius Anatomical Plate System | Hand Innovations, Inc. | 2005 | 1 |
| −5 | K051735 | Peri-Loc Locking Bone Plates and Locking Bone Screws for the Upper Extremity | Smith & Nephew, Inc. | 2005 | — |
| −4 | K071563 | Peri-Loc Periarticular Locked Plating System | Smith & Nephew, Inc. | 2007 | — |
| −3 | K090675 | Smith & Nephew, Inc. VLP Foot Plating, Screw System and Accessories | Smith & Nephew, Inc. | 2009 | — |
| −2 | K100776 | Synthes 2.4 MM/2.7 MM Variable Angle LCP Forefoot/Midfoot System | Synthes (Usa) | 2010 | — |
| −1 | K182718 | Mini and Micro Fragments Reconstruction System – GMReis | Gm Dos Reis Industria E Comerico Ltda. | 2019 | — |
| 0 (this device) | K231684 | Quick - Radius Disposable Set | GM Dos Reis Industria e Comercio Ltda. | 2024 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1979 | 1 | 0 |
| 1988 | 1 | 0 |
| 1989 | 2 | 0 |
| 1990 | 1 | 0 |
| 1991 | 2 | 0 |
| 1992 | 1 | 0 |
| 1993 | 2 | 0 |
| 1994 | 4 | 0 |
| 1995 | 2 | 0 |
| 1996 | 8 | 0 |
| 1997 | 2 | 0 |
| 1998 | 5 | 0 |
| 1999 | 3 | 0 |
| 2000 | 12 | 0 |
| 2001 | 9 | 0 |
| 2002 | 5 | 0 |
| 2003 | 7 | 0 |
| 2004 | 9 | 0 |
| 2005 | 7 | 0 |
| 2006 | 7 | 0 |
| 2007 | 7 | 0 |
| 2008 | 7 | 0 |
| 2009 | 11 | 0 |
| 2010 | 4 | 0 |
| 2011 | 1 | 0 |
| 2012 | 1 | 0 |
| 2014 | 1 | 0 |
| 2015 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in HRS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new HRS device
- #1 K222465 Tyber Medical Anatomical Plating Systemscore 27.5 · 16 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K182718 | Mini and Micro Fragments Reconstruction System – GMReisSummary page 3…redicate Devices: Legally marketed devices to which we are claiming “Substantial Equivalence” are the following: Mini and Micro Fragments Reconstruction System - GMReis (K182718) (Primary predicate device). Synthes (USA) 2.4mim VA-LCP Two-Column Narrow Volar Distal Radius Plates - Synthes (USA) (K092556) (… | 2019 |
| † | K092556 | Synthes (Usa) 2.4MM VA-LCP Two-Column Narrow Volar Distal Radius | 2009 |
| † | K200332 | EXPERT - Joint Fixation System | 2020 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 28 years and passes through 6 companies; a new generation was cleared every 1.8 years on median.
- 36 of the 134 ancestors have a recall of any class.
- 3 other devices also cite its predicate K182718.
How does its category compare?
All HRS devicesHRS Plate, Fixation, Bone: FDA decisions, review times, recalls and adverse event reports over 20 years. 2024, this device’s year, is highlighted.
FDA decisions per year · HRS
54in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · HRS
90in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · HRS
1in 2025
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · HRS
2,306in 2025
MAUDE reports naming product code HRS, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 35 | 63 | 2 | 339 |
| 2008 | 35 | 87 | 11 | 311 |
| 2009 | 47 | 85 | 3 | 435 |
| 2010 | 49 | 100 | 16 | 491 |
| 2011 | 43 | 88 | 5 | 773 |
| 2012 | 59 | 106 | 4 | 1,663 |
| 2013 | 56 | 89 | 11 | 2,643 |
| 2014 | 76 | 57 | 0 | 2,413 |
| 2015 | 56 | 97 | 7 | 3,095 |
| 2016 | 44 | 109 | 5 | 2,276 |
| 2017 | 57 | 122 | 3 | 2,220 |
| 2018 | 40 | 116 | 2 | 2,663 |
| 2019 | 46 | 89 | 25 | 3,359 |
| 2020 | 48 | 88 | 1 | 2,790 |
| 2021 | 40 | 87 | 9 | 2,442 |
| 2022 | 47 | 144 | 3 | 1,700 |
| 2023 | 40 | 120 | 1 | 2,049 |
| 2024 | 54 | 96 | 0 | 1,849 |
| 2025 | 54 | 90 | 1 | 2,306 |
| 2026 | 51 | 82 | 3 | — |
What is it indicated for?
Quick - Radius Disposable Set is intended for fracture fixation, arthrodesis, reconstruction, and osteotomy fixation of the hand and wrist. The use of locking plate and screw systems is suited for treatment of fractures in osteopenic bone.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K231684 · printed Nov 6, 2026
Cite this page
510(k) Report. “K231684: Quick - Radius Disposable Set.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K231684
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026