# K231850: QUARTEX® Occipito-Cervico-Thoracic Spinal System ExcelsiusGPS® Instruments

- Pathway: 510(k) (Traditional)
- Applicant: Globus Medical, Inc.
- Decided: Mar 14, 2024 after 265 days
- Product code: NKG (Posterior Cervical Screw System)
- Device class: 2
- Regulation: 21 CFR 888.3075
- Recalls of this device: none
- Data: FDA decisions to Oct 25, 2026; recalls to Oct 12, 2026

## Lineage
Longest line of descent: 21 generations back to K040583 (2004). 704 ancestors in all.
2 later devices descend from it; 1 cites it directly.
9 of 707 devices in its family (counting itself) have a Class I recall.

## Predicates on the family tree (from the FDA summary)
- K161591: QUARTEX™ Occipito-Cervico-Thoracic Spinal System, Globus Navigation Instruments, Globus Medical, Inc. (2016) Summary page 6.
- K211957: QUARTEX Occipito-Cervico-Thoracic Spinal System, Globus Navigation Instruments, Globus Medical, Inc. (2021) Summary page 6.
- K171651: Excelsius GPS, Globus Medical, Inc. (2017) Summary page 6.
- K200047: ExcelsiusGPS Cranial 1.0 Module, Globus Medical, Inc. (2020) Summary page 6.
- K211616: ExcelsiusHub, Globus Medical, Inc. (2021) Summary page 6.

## Most influential descendants
- K252327: CMORE® CT System; CMORE® CT System Navigated Instruments (2025), 1 descendant of its own
- K254045: CarboClear® Posterior Cervical Screw System; CarboClear® Hybrid Posterior Cervical Screw System (2026), 0 descendants of its own

## Indications for use
The QUARTEX® Occipito-Cervico-Thoracic Spinal System implants are intended to provide immobilization and stabilization of spinal segments as an adjunct to fusion for the following acute and chronic instabilities of the craniocervical junction, the cervical spine (C l-C7) and the thoracic spine (Tl-T3): traumatic spinal fractures and/or traumatic dislocations; instability or deformity; failed previous fusions (e.g. pseudoarthrosis); tumors involving the cervical/thoracic spine; and degenerative disease, including intractable radiculopathy and/or myelopathy, neck and/or arm pain of discogenic origin as confirmed by radiographic studies, and degenerative disease of the facets with instability. These implants are also intended to restore the integrity of the spinal column even in the absence of fusion for a limited time period in patients with advanced stage tumors involving the cervical spine in whom life expectancy is of insufficient duration to permit achievement of fusion. In order to achieve additional levels of fixation, rods may be connected to occipital cervical thoracic or thoracolumbar stabilization systems ranging in diameter from 3.2mm to 6.5mm, using corresponding connectors. The ExcelsiusGPS® is intended for use as an aid for precisely locating anatomical structures and for spatial positioning and orientation of an instrument holder or guide to be used by surgeons for navigating and/or guiding compatible surgical instruments in open or percutaneous procedures provided that the required fiducial markers and rigid patient anatomy can be identified on CT scans or fluoroscopy. The system is indicated for the placement of spinal and orthopedic bone screws and interbody spacers. The ExcelsiusHub™ is intended for use as an aid for precisely locating anatomical structures to be used by surgeons for navigating compatible surgical instruments in open or percutaneous procedures provided that the required fiducial markers and rigid patient anatomy can be identified on CT scans or fluoroscopy. The system is indicated for the placement of spinal and orthopedic bone screws and interbody fusion devices.