510(k) · Cleared
ClearedAdravision Perio
Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly
Adra Corporation · QIH Automated Radiological Image Processing Software
Cleared on Dec 5, 2023 as substantially equivalent to K210187 (Overjet, Inc., 2021) after a 113-day review. Its family tree reaches back 9 generations to 1993.
- Decided
- Dec 5, 2023
- Review
- 113 days
- Class
- Class II
- Product code
- QIH
- Recalls
- None
- Predicates
- 1
Its longest line of descent runs back 9 generations to K930527 (1993). 10 ancestors in all. No later device cites it as a predicate yet.
- Root · 9 generations backK930527 Dental LinkEscan, Inc. · 1993
- 5 generations between
- 3 generations backK173094 OrthoVisionEwoosoft Co., Ltd. · 2017
- 2 generations backK192888 EzOrthoEwoosoft Co., Ltd. · 2020
- 1 generation backK210187 Overjet Dental AssistOverjet, Inc. · 2021
- This deviceK232440 Adravision PerioAdra Corporation · 2023
Show all 9 generations
- Root · 9 generations backK930527 Dental LinkEscan, Inc. · 1993
- 8 generations backK955237 Tigerscan/TigerviewTau Corp. · 1996
- 7 generations backK012439 Dentaleye 2 Dental Image Management SystemRadco Data AB · 2002
- 6 generations backK043104 Kodak Orthodontic Imaging and Oms Imaging 8.0Practiceworks, Inc. · 2005
- 5 generations backK122427 CS Orthodontic Imaging Software CS Oms Imaging SoftwareCarestream Dental, LLC · 2012
- 4 generations backK131570 OrthovisionEwoosoft Co., Ltd. · 2013
- 3 generations backK173094 OrthoVisionEwoosoft Co., Ltd. · 2017
- 2 generations backK192888 EzOrthoEwoosoft Co., Ltd. · 2020
- 1 generation backK210187 Overjet Dental AssistOverjet, Inc. · 2021
- This deviceK232440 Adravision PerioAdra Corporation · 2023
View FIG. 1 as a table
Line of descent and top descendants
| Generation | Number | Device | Applicant | Decided | Recalls |
|---|---|---|---|---|---|
| −9 | K930527 | Dental Link | Escan, Inc. | 1993 | — |
| −8 | K955237 | Tigerscan/Tigerview | Tau Corp. | 1996 | — |
| −7 | K012439 | Dentaleye 2 Dental Image Management System | Radco Data AB | 2002 | — |
| −6 | K043104 | Kodak Orthodontic Imaging and Oms Imaging 8.0 | Practiceworks, Inc. | 2005 | — |
| −5 | K122427 | CS Orthodontic Imaging Software CS Oms Imaging Software | Carestream Dental, LLC | 2012 | — |
| −4 | K131570 | Orthovision | Ewoosoft Co., Ltd. | 2013 | — |
| −3 | K173094 | OrthoVision | Ewoosoft Co., Ltd. | 2017 | — |
| −2 | K192888 | EzOrtho | Ewoosoft Co., Ltd. | 2020 | — |
| −1 | K210187 | Overjet Dental Assist | Overjet, Inc. | 2021 | — |
| 0 (this device) | K232440 | Adravision Perio | Adra Corporation | 2023 | — |
Other ancestors by year cleared
| Year cleared | Devices | With a Class I recall |
|---|---|---|
| 1998 | 1 | 0 |
Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.
Planning a device in QIH? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.
Top candidate predicates for a new QIH device
- #1 K213998 cvi42 Auto Imaging Software Applicationscore 23.5 · 7 generations · no Class I recall
- #2 Held for the reportin the report
- #3 Held for the reportin the report
What was it cleared against? (1)
Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.
| Type | Number | Device | Decided |
|---|---|---|---|
| * | K210187 | Overjet Dental AssistSummary page 5…not evaluated the performance of the device on primary dentition. Predicate Device: Overjet Inc., Overjet Dental Assist, 510(k): K210187 Trade Name: Overjet Dental Assisst Classification Name: Medical Image M… | 2021 |
What descends from it?
No later submission names this one as a predicate yet.
Has anything in its family been recalled? (0 Class I)
No FDA recall names this device.
No ancestor or descendant has a Class I recall.
What does this lineage say?
- The line of descent spans 30 years and passes through 8 companies; a new generation was cleared every 2.8 years on median.
- None of the 10 ancestors has a recall.
- 4 other devices also cite its predicate K210187.
How does its category compare?
All QIH devicesQIH Automated Radiological Image Processing Software: FDA decisions, review times, recalls and adverse event reports over 20 years. 2023, this device’s year, is highlighted.
FDA decisions per year · QIH
94in 2025
2026 to Oct 25, outlined.
Median 510(k) review, days · QIH
150in 2025
Receipt to decision; years with fewer than 3 clearances left blank.
Recalls per year · QIH
1so far in 2026, the most since 2007
Class I (0 since 2007) Class II/III not classified
Adverse event reports per year · QIH
4in 2025
MAUDE reports naming product code QIH, not matched to any one device; reports are not rates.
View these four charts as a table
| Year | Decisions | Median 510(k) review, days | Recalls (Class I) | MAUDE reports |
|---|---|---|---|---|
| 2007 | 0 | — | 0 | 0 |
| 2008 | 0 | — | 0 | 0 |
| 2009 | 0 | — | 0 | 0 |
| 2010 | 0 | — | 0 | 0 |
| 2011 | 0 | — | 0 | 0 |
| 2012 | 0 | — | 0 | 0 |
| 2013 | 0 | — | 0 | 0 |
| 2014 | 0 | — | 0 | 0 |
| 2015 | 0 | — | 0 | 0 |
| 2016 | 0 | — | 0 | 0 |
| 2017 | 0 | — | 0 | 0 |
| 2018 | 0 | — | 0 | 0 |
| 2019 | 2 | — | 0 | 0 |
| 2020 | 11 | 145 | 0 | 0 |
| 2021 | 19 | 125 | 0 | 0 |
| 2022 | 25 | 134 | 0 | 0 |
| 2023 | 45 | 151 | 0 | 0 |
| 2024 | 64 | 141 | 0 | 2 |
| 2025 | 94 | 150 | 0 | 4 |
| 2026 | 78 | 130 | 1 | — |
What is it indicated for?
Adravision Perio is a radiological semi-automated image processing software device intended to aid dental professionals in the measurements of mesial and distal bone levels associated with each tooth from bitewing and periapical radiographs. It should not be used in-lieu of full patient evaluation or solely relied upon to make or confirm a diagnosis. The intended users of Adravision Perio are trained professionals including, but not limited to, dentists…
Read the full statement (114 words)
Adravision Perio is a radiological semi-automated image processing software device intended to aid dental professionals in the measurements of mesial and distal bone levels associated with each tooth from bitewing and periapical radiographs. It should not be used in-lieu of full patient evaluation or solely relied upon to make or confirm a diagnosis.
The intended users of Adravision Perio are trained professionals including, but not limited to, dentists and dental hygienists.
The intended patient population of the device is patients living in the United States, who are 22 years old or older, and that do not have any remaining primary teeth. Adra Corporation has not evaluated the performance of the device on primary dentition.
Indications for use as stated in the FDA summary.
https://510kreport.com/device/K232440 · printed Nov 6, 2026
Cite this page
510(k) Report. “K232440: Adravision Perio.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K232440
Report an extraction error
Are you the manufacturer?
Record history
- FDA decision record loaded May 2, 2026
- Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
- Lineage and recalls computed Nov 3, 2026
- Page last updated Nov 3, 2026