510(k) Report

510(k) · Cleared

Cleared

Brainomix 360 Triage Stroke

K232496510(k) TraditionalCleared Nov 21, 202396-day reviewClass II21 CFR 892.2080

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Brainomix Limited · QAS Radiological Computer-Assisted Triage And Notification Software

Cleared on Nov 21, 2023 as substantially equivalent to K222884 (Ischemaview, Inc., 2023) after a 96-day review. Its family tree reaches back 4 generations to 2018. 1 later device descends from it.

Decided
Nov 21, 2023
Review
96 days
Class
Class II
Product code
QAS
Recalls
None
Predicates
1

Its longest line of descent runs back 4 generations to DEN170073 (2018). 1 later device descends from it, 1 citing it directly.

  1. Root · 4 generations backDEN170073 ContaCTViz.Al, Inc. · 2018
  2. 3 generations backK180647 BriefCaseAidoc Medical, Ltd. · 2018
  3. 2 generations backK200855 CINAAvicenna.Ai · 2020
  4. 1 generation backK222884 Rapid NCCT StrokeIschemaview, Inc. · 2023
  5. This deviceK232496 Brainomix 360 Triage StrokeBrainomix Limited · 2023
  6. Descendant · cites it directly · 0 of its ownK251983 Brainomix 360 Triage StrokeBrainomix Limited · 2025

Most influential descendants

Showing 1 of 1 · See all
  • K251983Brainomix 360 Triage StrokeBrainomix Limited · 2025 · cites it directly0descendants
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4DEN170073ContaCTViz.Al, Inc.2018—
−3K180647BriefCaseAidoc Medical, Ltd.2018—
−2K200855CINAAvicenna.Ai2020—
−1K222884Rapid NCCT StrokeIschemaview, Inc.2023—
0 (this device)K232496Brainomix 360 Triage StrokeBrainomix Limited2023—
+1K251983Brainomix 360 Triage StrokeBrainomix Limited2025—

Descendants by year cleared

Year clearedDevicesWith a Class I recall
202510
FIG. 1 — Lineage of K232496, 2018–2025Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in QAS? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new QAS device

  1. #1 K203508 BriefCasescore 25.5 · 4 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K222884Rapid NCCT Stroke
Summary page 5
…ice The Brainomix 360 Triage Stroke device is claimed to be substantially equivalent to the following legally marketed predicate device: iSchemaView’s Rapid NCCT Stroke (K222884). Indications for Use Brainomix 360 Triage Stroke is a radiological computer aided triage and notification software indicated fo…
Ischemaview, Inc.2023—
†K231195Brainomix 360 Triage ICHBrainomix Limited2023—

Also cleared against K222884: 3 other devices →

What descends from it? (1)

1 later device cites it directly; ranked here by how many devices descend from each in turn.

NumberDeviceApplicantDecidedDescendants
K251983Brainomix 360 Triage StrokeBrainomix Limited20250

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 5 years and passes through 5 companies; a new generation was cleared every 1.9 years on median.
  • None of the 4 ancestors has a recall.
  • Of its descendants, K251983 (Brainomix Limited, 2025) has gone furthest, with 0 descendants of its own.
  • 3 other devices also cite its predicate K222884.

How does its category compare?

All QAS devices

QAS Radiological Computer-Assisted Triage And Notification Software: FDA decisions, review times, recalls and adverse event reports over 20 years. 2023, this device’s year, is highlighted.

FDA decisions per year · QAS

15in 2025

2018: 32019: 52020: 122021: 52022: 152023: 112024: 122025: 152026 (partial year): 11
2007high 15 (2022) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · QAS

101in 2025

2019: 111 days median2020: 112 days median2021: 86 days median2022: 116 days median2023: 98 days median2024: 136 days median2025: 101 days median2026 (partial year): 104 days median
2007high 136 (2024) · low 86 (2021)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · QAS

No recall names QAS since 2007.

Adverse event reports per year · QAS

No MAUDE report names QAS since 2007.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20150—00
20160—00
20170—00
20183—00
2019511100
20201211200
202158600
20221511600
2023119800
20241213600
20251510100
2026111040—

What is it indicated for?

Brainomix 360 Triage Stroke is a radiological computer aided triage and notification software indicated for use in the analysis of non-contrast head CT (NCCT) images to assist hospital networks and trained clinicians in workflow triage by flagging and communicating suspected positive findings of head NCCT images for large vessel occlusion (LVO) of the intracranial ICA and M1 and intracranial hemorrhage (ICH). Specifically, the device is intended to be…

Read the full statement (525 words)

Brainomix 360 Triage Stroke is a radiological computer aided triage and notification software indicated for use in the analysis of non-contrast head CT (NCCT) images to assist hospital networks and trained clinicians in workflow triage by flagging and communicating suspected positive findings of head NCCT images for large vessel occlusion (LVO) of the intracranial ICA and M1 and intracranial hemorrhage (ICH). Specifically, the device is intended to be used for the triage of images acquired from adult patients in the acute setting, within 24 hours of the onset of the acute symptoms, or where this is unclear, since last known well (LKW) time. It is not intended to detect isolated subarachnoid hemorrhage and symmetrical bilateral MCA occlusions.

Brainomix 360 Triage Stroke uses an artificial intelligence algorithm to analyze images and highlight cases with detected NCCT LVO or ICH on the Brainomix server on premise or in the cloud in parallel to the ongoing standard of care image interpretation. The user is presented with notifications for cases with suspected LVO or ICH findings via a web user interface or mobile application. Notifications include compressed preview images that are meant for informational purposes only and are not intended for diagnostic use beyond notification.

The device does not alter the original medical image, and it is not intended to be used as a primary diagnostic device. The results of Brainomix 360 Triage Stroke are intended to be used in conjunction with other patient information and based on professional judgment to assist with triage/prioritization of medical images. Notified clinicians are ultimately responsible for reviewing full images per the standard of care.

Cautions:

• All patients should get adequate care for their symptoms, including angiography and/or other appropriate care per the standard clinical practice, irrespective of the output of Brainomix 360 Triage Stroke.

• Brainomix 360 Triage Stroke is not intended to be a rule-out device and for cases that have been processed by the device without notification for "Suspected L VO" should not be viewed as indicating that LVO is excluded. All cases should undergo angiography, per the standard stroke workup.

Limitations:

• Brainomix 360 Triage Stroke is not intended for mobile diagnostic use. Images viewed on a mobile platform are compressed preview images and not for diagnostic interpretation.

• Brainomix 360 Triage Stroke does not replace the need for CT A in ischemic stroke workup - it provides workflow prioritization and notification only.

• Brainomix 360 Triage Stroke has been validated and is intended to be used on Siemens, GE and Philips scanners.

• Brainomix 360 Triage Stroke is not intended to be used on patients with recent (within 6 weeks) neurosurgery or endovascular neurointervention or recent (within 4 weeks) previous diagnosis of stroke.

• Brainomix 360 Triage Stroke is not intended to detect isolated subarachnoid hemorrhage and symmetrical bilateral MCA occlusions.

Contraindications: Brainomix 360 Triage Stroke is not suitable for use with scan data containing image features associated with:

• tumors or abscesses

• coils, shunts, embolization or movement artifacts

Brainomix 360 Triage Stroke is not intended to be used for analyzing CT images in intracranial vascular pathologies such as arterial aneurysms, arteriovenous malformations or venous thrombosis.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K232496: Brainomix 360 Triage Stroke.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K232496

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026