510(k) Report

510(k) · Cleared

Cleared

FilteredFlo Warming Blankets

K232638510(k) TraditionalCleared Oct 24, 202355-day reviewClass II21 CFR 870.5900

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Iob Medical, Inc. · DWJ System, Thermal Regulating

Cleared on Oct 24, 2023 as substantially equivalent to K231596 (Iob Medical, Inc., 2023) after a 55-day review. Its family tree reaches back 4 generations to 2002.

Decided
Oct 24, 2023
Review
55 days
Class
Class II
Product code
DWJ
Recalls
None
Predicates
1

Its longest line of descent runs back 4 generations to K021473 (2002). 5 ancestors in all. No later device cites it as a predicate yet.

  1. Root · 4 generations backK021473 Bair Hugger Temperature Management SystemAugustine Medical, Inc. · 2002
  2. 3 generations backK162679 IOB Temperature Management SystemIob Medical, Inc. · 2017
  3. 2 generations backK190221 IOB Warming BlanketsIob Medical, Inc. · 2019
  4. 1 generation backK231596 IOB Temperature Management SystemIob Medical, Inc. · 2023
  5. This deviceK232638 FilteredFlo Warming BlanketsIob Medical, Inc. · 2023
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K021473Bair Hugger Temperature Management SystemAugustine Medical, Inc.2002—
−3K162679IOB Temperature Management SystemIob Medical, Inc.2017—
−2K190221IOB Warming BlanketsIob Medical, Inc.2019—
−1K231596IOB Temperature Management SystemIob Medical, Inc.2023—
0 (this device)K232638FilteredFlo Warming BlanketsIob Medical, Inc.2023—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
202210
FIG. 1 — Lineage of K232638, 2002–2023Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in DWJ? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new DWJ device

  1. #1 K260278 ThermAffyx (TM) Patient Safety Systemscore 12.8 · 5 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K231596IOB Temperature Management System
Summary page 4
…ets Common or Usual Name: Warming Blanket Classification Name: Thermal Regulating System (21 CFR 870.5900) Regulatory Class: II Product Code: DWJ III. PREDICATE DEVICE K231596 IOB Temperature Management System Model IOB-507 IV. DEVICE DESCRIPTION The FilteredFlo warming blankets are used with the IOB Te…
Iob Medical, Inc.2023—

Also cleared against K231596: 1 other device →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 21 years and passes through 2 companies; a new generation was cleared every 3.7 years on median.
  • None of the 5 ancestors has a recall.
  • 1 other device also cites its predicate K231596.

How does its category compare?

All DWJ devices

DWJ System, Thermal Regulating: FDA decisions, review times, recalls and adverse event reports over 20 years. 2023, this device’s year, is highlighted.

FDA decisions per year · DWJ

3in 2025

2007: 42008: 32009: 32010: 82011: 42012: 52013: 52014: 42016: 22017: 52018: 32019: 22020: 52021: 22022: 22023: 62024: 22025: 32026 (partial year): 5
2007high 8 (2010) · low 0 (2015)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · DWJ

131in 2025

2007: 106 days median2008: 73 days median2009: 106 days median2010: 134 days median2011: 180 days median2012: 69 days median2013: 77 days median2014: 131 days median2017: 153 days median2018: 95 days median2020: 30 days median2023: 42 days median2025: 131 days median2026 (partial year): 99 days median
2007high 180 (2011) · low 30 (2020)2026

Receipt to decision; years with fewer than 3 clearances left blank.

Recalls per year · DWJ

3in 2024

2009: 62010: 22011: 72012: 12013: 22015: 12017: 32018: 52019: 32020: 22021: 12022: 52024: 32026 (partial year): 3
2007high 7 (2011) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · DWJ

2,384in 2025

2007: 522008: 402009: 712010: 1042011: 1362012: 1062013: 732014: 1162015: 2452016: 1,4002017: 1,4732018: 1,5172019: 2,2942020: 2,5462021: 2,6892022: 3,2262023: 3,4552024: 3,3292025: 2,384
2007high 3,455 (2023) · low 40 (2008)2025

MAUDE reports naming product code DWJ, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20074106052
2008373040
20093106671
201081342104
201141807136
20125691106
2013577273
201441310116
20150—1245
20162—01,400
2017515331,473
201839551,517
20192—32,294
202053022,546
20212—12,689
20222—53,226
202364203,455
20242—33,329
2025313102,384
20265993—

What is it indicated for?

The FilteredFlo Warming Blanket is intended to be used with the IOB-507 patient warming system. The IOB-507 Temperature Management system is indicated for hypothermic patients or normothermic patients for whom induced hyperthermia or localized increase in temperature is clinically indicated. These blankets are intended for adult and pediatric use.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K232638: FilteredFlo Warming Blankets.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 6, 2026. https://510kreport.com/device/K232638

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026