510(k) Report

510(k) · Cleared

Cleared

TD 200® Automated TEE Probe Disinfector with TD-12® High-Level Disinfectant with QwikCheck™ Chemical Indicator

K233049510(k) TraditionalCleared Nov 21, 202357-day reviewClass II21 CFR 892.1570

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Cs Medical, LLC · PSW High Level Disinfection Reprocessing Instrument For Ultrasonic Transducers, Liquid

Cleared on Nov 21, 2023 as substantially equivalent to K192228 (Cs Medical, LLC, 2020) after a 57-day review. Its family tree reaches back 6 generations to 1999.

Decided
Nov 21, 2023
Review
57 days
Class
Class II
Product code
PSW
Recalls
None
Predicates
2

Its longest line of descent runs back 6 generations to K991487 (1999). 16 ancestors in all, the oldest K914145 (1994). No later device cites it as a predicate yet.

  1. Root · 6 generations backK991487 Cidex Opa SolutionAdvanced Sterilization Products · 1999
  2. 5 generations backK030004 0.55% Orth-Phthalaldehyde SolutionAdvanced Sterilization Products · 2003 · Recalled
  3. 4 generations backK070627 Opaciden SolutionCiden Technologies, LLC · 2007
  4. 3 generations backK120306 Rapicide Opa-28Minntech Corp. · 2012
  5. 2 generations backK160921 CS-Medical TD 100 Disinfector with TD-5 and TD-8 High Level…Cs Medical, LLC · 2016
  6. 1 generation backK192228 CS Medical TD 200 disinfector with TD-12 high-level disinfectant, CS…Cs Medical, LLC · 2020
  7. This deviceK233049 TD 200® Automated TEE Probe Disinfector with TD-12® High-Level…Cs Medical, LLC · 2023
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−6K991487Cidex Opa SolutionAdvanced Sterilization Products1999—
−5K0300040.55% Orth-Phthalaldehyde SolutionAdvanced Sterilization Products20032
−4K070627Opaciden SolutionCiden Technologies, LLC2007—
−3K120306Rapicide Opa-28Minntech Corp.2012—
−2K160921CS-Medical TD 100 Disinfector with TD-5 and TD-8 High Level Disinfectants, CS…Cs Medical, LLC2016—
−1K192228CS Medical TD 200 disinfector with TD-12 high-level disinfectant, CS Medical…Cs Medical, LLC2020—
0 (this device)K233049TD 200® Automated TEE Probe Disinfector with TD-12® High-Level Disinfectant…Cs Medical, LLC2023—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
199410
199510
199710
200010
200530
200610
200710
200910
FIG. 1 — Lineage of K233049, 1999–2023Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in PSW? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new PSW device

  1. #1 K230381 Ethos Automated Ultrasound Probe Cleaner…score 5.5 · 1 generation · no Class I recall
  2. #2 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (2)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary; numbers the summary cites that cannot be its predicate are marked – and kept off the family tree.

TypeNumberDeviceApplicantDecidedRecalls
*K192228CS Medical TD 200 disinfector with TD-12 high-level disinfectant, CS Medical TD-12…
Summary page 5
…ct Code, MED, JOJ Legally Marketed Predicate Devices 1. TD 200/TD-12 disinfector/disinfectant system (K192228) – Primary Predicate 2. IBT Scientific Peracid Test (K964264) Description of the CS Medical TD 200® Disinfector with TD-12® Hig…
Cs Medical, LLC2020—
Kept off the family treeK964264FDA’s K964264 is High Range Peroxide Test Strip
Our reading of the summary gave K964264, FDA’s number for High Range Peroxide Test Strip (Integrated Biomedical Technology, Inc.). Its FDA name has none of the distinctive words the summary uses for the device it names, “IBT Scientific Peracid Test”. Kept off the family tree.
Summary page 5
…MED, JOJ Legally Marketed Predicate Devices 1. TD 200/TD-12 disinfector/disinfectant system (K192228) – Primary Predicate 2. IBT Scientific Peracid Test (K964264) Description of the CS Medical TD 200® Disinfector with TD-12® High Level Disinfectant and QwikCheck™ Indicator The TD 200 disin…
Integrated Biomedical Technology, Inc.1997—

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 24 years and passes through 4 companies; a new generation was cleared every 4.1 years on median.
  • 5 of the 16 ancestors have a recall of any class.

How does its category compare?

All PSW devices

PSW High Level Disinfection Reprocessing Instrument For Ultrasonic Transducers, Liquid: FDA decisions, review times, recalls and adverse event reports over 20 years. 2023, this device’s year, is highlighted.

FDA decisions per year · PSW

2in 2023

2015: 12016: 12019: 12020: 12023: 2
2007high 2 (2023) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · PSW

Too few PSW 510(k)s in any year since 2007 to give a median.

Recalls per year · PSW

No recall names PSW since 2007.

Adverse event reports per year · PSW

No MAUDE report names PSW since 2007.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—00
20080—00
20090—00
20100—00
20110—00
20120—00
20130—00
20140—00
20151—00
20161—00
20170—00
20180—00
20191—00
20201—00
20210—00
20220—00
20232—00
20240—00
20250—00
20260—0—

What is it indicated for?

The TD 200® Automated TEE Probe Disinfector with TD-12® High Level Disinfectant with QwikCheck™ Chemical Indicators is designed to provide high-level disinfection of Transesophageal (TEE) ultrasound probes. The system can use TD-12® disinfectant, which is designed to be used only with the TD 200® disinfector. The disinfectant bottles cannot be reused in the system. TD-12® disinfectant is intended for use as single use high-level disinfectant to be used…

Read the full statement (156 words)

The TD 200® Automated TEE Probe Disinfector with TD-12® High Level Disinfectant with QwikCheck™ Chemical Indicators is designed to provide high-level disinfection of Transesophageal (TEE) ultrasound probes. The system can use TD-12® disinfectant, which is designed to be used only with the TD 200® disinfector. The disinfectant bottles cannot be reused in the system.

TD-12® disinfectant is intended for use as single use high-level disinfectant to be used exclusively in the TD 200® disinfector for high-level disinfection of TEE ultrasound probes.

TD-12® high level disinfectant and TD 200® disinfector is intended for use by qualified individuals trained in its use.

TD-12® disinfectant should be used with the following contact conditions in TD 200® disinfector:

High-Level Disinfectant Time Temperature Minimum Recommended Concentration

TD-12® 3 minutes 38°C 1750 ppm peracetic acid

QwikCheck™ Chemical Indicators are used prior to the disinfection cycle to ensure that the disinfectant used is above the minimum recommended concentration (MRC) of 1750ppm peracetic acid.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K233049: TD 200® Automated TEE Probe Disinfector with TD-12® High-Level Disinfectant with QwikCheck™ Chemical Indicator.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 5, 2026. https://510kreport.com/device/K233049

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026