510(k) Report

510(k) · Cleared

Cleared

Traus SSG10 Surgical System

K233153510(k) TraditionalCleared Sep 20, 2024359-day reviewClass II21 CFR 882.4360

Data to Oct 25, 2026 (FDA decisions) Oct 12, 2026 (recalls) Sep 30, 2026 (MAUDE) refreshed weekly, last Nov 3, 2026

Saeshin Precision Co., Ltd. · HBC Motor, Drill, Electric

Cleared on Sep 20, 2024 as substantially equivalent to K173066 (Bien-Air Surgery SA, 2018) after a 359-day review. Its family tree reaches back 4 generations to 2000.

Decided
Sep 20, 2024
Review
359 days
Class
Class II
Product code
HBC
Recalls
None
Predicates
1

Its longest line of descent runs back 4 generations to K002224 (2000). 9 ancestors in all. No later device cites it as a predicate yet.

Other ancestors, by year cleared 2011: 1 other ancestor2008: 1 other ancestor2004: 1 other ancestor2002: 1 other ancestor2001: 1 other ancestorK002224 · XPS 3000 System · Medtronic Xomed · 2000K041523 · XPS 3000 System · Medtronic Xomed, Inc. · 2004K083720 · Osseoduo, Shaver Handpiece S80 and S120, Micromotor 80K · Bien-Air Surgery SA · 2009 · recalledK173066 · OSSEODUO Shaver and Drill System · Bien-Air Surgery SA · 2018200020052010201520202025
  1. Root · 4 generations backK002224 XPS 3000 SystemMedtronic Xomed · 2000
  2. 3 generations backK041523 XPS 3000 SystemMedtronic Xomed, Inc. · 2004
  3. 2 generations backK083720 Osseoduo, Shaver Handpiece S80 and S120, Micromotor 80KBien-Air Surgery SA · 2009 · Recalled
  4. 1 generation backK173066 OSSEODUO Shaver and Drill SystemBien-Air Surgery SA · 2018
  5. This deviceK233153 Traus SSG10 Surgical SystemSaeshin Precision Co., Ltd. · 2024
View FIG. 1 as a table

Line of descent and top descendants

GenerationNumberDeviceApplicantDecidedRecalls
−4K002224XPS 3000 SystemMedtronic Xomed2000—
−3K041523XPS 3000 SystemMedtronic Xomed, Inc.2004—
−2K083720Osseoduo, Shaver Handpiece S80 and S120, Micromotor 80KBien-Air Surgery SA20092
−1K173066OSSEODUO Shaver and Drill SystemBien-Air Surgery SA2018—
0 (this device)K233153Traus SSG10 Surgical SystemSaeshin Precision Co., Ltd.2024—

Other ancestors by year cleared

Year clearedDevicesWith a Class I recall
200110
200210
200410
200810
201110
FIG. 1 — Lineage of K233153, 2000–2024Source: FDA 510(k) summaries, read by 510(k) Report · How lineage is built

Get the monthly Device Review Tracker

Notable FDA decisions, review times and new Class I recalls. See an issue.

Sources: FDA 510(k) database (decision fields), the FDA summary (predicates and indications), FDA recall and enforcement reports, and MAUDE; processed by 510(k) Report. Verify on FDA.gov · Methodology and accuracy.

Planning a device in HBC? A 510(k) Report weighs predicate choices, recall history and review times for a new device like this one.

Top candidate predicates for a new HBC device

  1. #1 K254174 Surgical Power Systemscore 14.7 · 10 generations · no Class I recall
  2. #2 Held for the reportin the report
  3. #3 Held for the reportin the report
Get a 510(k) Report

What was it cleared against? (1)

Devices the submitter claimed this one is substantially equivalent to (*), and reference devices cited for a specific test or feature (†), as written in the FDA summary.

TypeNumberDeviceApplicantDecidedRecalls
*K173066OSSEODUO Shaver and Drill System
Summary page 6
…e 6 === K233153, Page 2 of 4 Predicate Device: Manufacturer: Bien-Air Surgery SA 510(k) Number: K173066 Trade/Device Name: OSSEODUO Shaver and Drill System Regulation Number: 21 CFR 882.4360 Regulation Name: Electric cranial drill mo…
Bien-Air Surgery SA2018—

Also cleared against K173066: 2 other devices →

What descends from it?

No later submission names this one as a predicate yet.

Has anything in its family been recalled? (0 Class I)

No FDA recall names this device.

No ancestor or descendant has a Class I recall.

What does this lineage say?

  • The line of descent spans 24 years and passes through 4 companies; a new generation was cleared every 6.2 years on median.
  • 5 of the 9 ancestors have a recall of any class.
  • 2 other devices also cite its predicate K173066.

How does its category compare?

All HBC devices

HBC Motor, Drill, Electric: FDA decisions, review times, recalls and adverse event reports over 20 years. 2024, this device’s year, is highlighted.

FDA decisions per year · HBC

2in 2024

2008: 12009: 12013: 22014: 12016: 12017: 22018: 12019: 12021: 12022: 22024: 22026 (partial year): 1
2007high 2 (2013) · low 0 (2007)2026

2026 to Oct 25, outlined.

Median 510(k) review, days · HBC

Too few HBC 510(k)s in any year since 2007 to give a median.

Recalls per year · HBC

9in 2022

2010: 12011: 92014: 12022: 9
2007high 9 (2011) · low 0 (2007)2026

Class I (0 since 2007) Class II/III not classified

Adverse event reports per year · HBC

635in 2025

2007: 52008: 62009: 22010: 12011: 12012: 32013: 10,6702014: 2,6432015: 1,9532016: 2,5412017: 2,0792018: 1,7792019: 1,7032020: 1,3042021: 9462022: 7602023: 6632024: 4272025: 635
2007high 10,670 (2013) · low 1 (2010)2025

MAUDE reports naming product code HBC, not matched to any one device; reports are not rates.

View these four charts as a table
YearDecisionsMedian 510(k) review, daysRecalls (Class I)MAUDE reports
20070—05
20081—06
20091—02
20100—11
20110—91
20120—03
20132—010,670
20141—12,643
20150—01,953
20161—02,541
20172—02,079
20181—01,779
20191—01,703
20200—01,304
20211—0946
20222—9760
20230—0663
20242—0427
20250—0635
20261—0—

What is it indicated for?

Traus SSG10 Surgical System is an electrical appliance intended to cut, shave, bone & tissue resection, grinding, and drilling in the cranium and spine. Shaver handpiece is not intended for use in neurosurgical procedures.

Indications for use as stated in the FDA summary.

Cite this page

510(k) Report. “K233153: Traus SSG10 Surgical System.” Lineage record from FDA 510(k) data and the FDA summary. Updated Nov 3, 2026. Accessed Nov 3, 2026. https://510kreport.com/device/K233153

Report an extraction error

Tell us what is wrong; we check it against the FDA summary.

Are you the manufacturer?

Send a correction or an update to this page, for example a newer model or a public statement about a recall.

Record history
  • FDA decision record loaded May 2, 2026
  • Summary read Oct 13, 2026 (extraction version 9eaa42aa01ed)
  • Lineage and recalls computed Nov 3, 2026
  • Page last updated Nov 3, 2026